Dongwoo Kim

Mr. Dongwoo Kim

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
SPSanghoon Park
Sanghoon Park
DKDongwoo Kim
Dongwoo Kim
GJGoosang Joe
Goosang Joe
SRSeong-Ryong Ryu
Seong-Ryong Ryu
Myoung Souk YeoMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim
The objective of this study is to establish boundary conditions to evaluate the cooling capacity of the Cooling Radiant Ceiling Panel (CRCP) considering the environment of a room equipped with the CRCP. The current study investigated the boundary conditions and derivation techniques from previous studies. Based on the results of the analysis, a heat transfer model was derived for a room fitted with CRCP. In addition, the heat transfer model was used to derive the factors affecting the cooling capacity of the CRCP and each factor was simulated and verified through this model. The effects of these factors on the capacity of the CRCP was established by using various boundary conditions. To verify the validity of the simulation model, the experimental results were compared with the cooling capacity for a specific case. As a result, it was established that even for the same panel, there was a variance in the cooling capacity of the CRCP based on the boundary conditions and that the influence of the surface exposed to the outdoors had more implications. Consequently, this study presents the influence factors to be considered when designing CRCP.

17 October 2017 in Energies
Verified
Journal Article
Open access
PDF file
DKDongwoo Kim
Dongwoo Kim
GJGoosang Joe
Goosang Joe
SPSanghoon Park
Sanghoon Park
Myoung Souk YeoMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim
In this study, we propose a method for the evaluation of the thermal output of radiant heating panels by employing a modification of the currently used method, which is recommended by existing standards, using cooling plates. We aim to overcome the absence in the measurement method of the downward thermal output as well as to address the challenges in the control of the heat transfer resistance of the heat transfer layer, which arise due to the contact resistance between the layers. Using the modified method, we compare the thermal performance of three types of raised floor integrated radiant heating panels that have different filler materials for the bottom insulation of the panel. We show that the most efficient sample panel is the one that is not filled with a material; with an efficiency of 70.1%. In addition, we show that the value of the gradient of the characteristic curve calculated by the existing method ranged between 7.2% to 14.9% larger than that obtained by modified method. This difference is attributed to the heat transfer resistance of the heat transfer layer that is present in the experiments, and has a value in the interval of 0.1096 m 2 K / W to 0.1582 m 2 K / W . This is caused by the contact resistance between the heat transfer layer and other layers, even though the heat transfer resistance of the heat transfer layer used in the experiment is 0.0985 m 2 K / W . The modified method proposed in this study reveals that the experimental results are not influenced by the heat transfer resistance of the heat transfer layer. We also show that our experimental results are reproducible.

17 October 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GJGoosang Joe
Goosang Joe
DKDongwoo Kim
Dongwoo Kim
SPSanghoon Park
Sanghoon Park
SPSojeong Park
Sojeong Park
Myoung Souk YeoMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim
The present study aims to evaluate whether downdraft can be prevented by applying a radiant floor heating system in glass curtain wall buildings. A radiant floor heating system does not directly supply heat to cold air, but does so via heat exchange with a cold airflow. Assessing whether a downdraft is prevented is, thus, necessary. For this assessment, a radiant floor heating system was applied to perimeter zones with different window types modeled using a computational fluid dynamics (CFD) simulation. The relationship between the radiant floor heating system and the windows was examined via an assessment of the resulting downdraft by considering the radiant heat exchange effect between the window and the floor. The assessment was conducted by utilizing a CFD simulation. The simulation results show that the temperature difference between the air supplied through the radiant floor heating system and the air descending along the cold surface of the window increased when the radiant floor heating system was applied to a narrow area with a high temperature. Furthermore, the airflow velocity increased with the heat exchange. The airflow re-entered the window side, and the downdraft in the occupied area exceeded the strict value specified by the standards. Conversely, if heat were applied according to the indoor thermal output by widening the radiant heat area of the radiant floor heating system, a downdraft could occur as a result of a blocking failure prior to the influx of the cold air into the occupied area caused by low surface temperatures. Therefore, applying a radiant floor heating system is advantageous in a perimeter zone without causing airflow inducement at the window side with acceptable surface temperatures.