Xiufang Liu

Dr. Xiufang Liu

School of Energy and Power Engineering, Xi’an Jiaotong University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
CZCHUNYU ZHAO
CHUNYU ZHAO
BZBeile Zhang
Beile Zhang
YZYuanming Zheng
Yuanming Zheng
SHShunyuan Huang
Shunyuan Huang
TYTongtong Yan
Tongtong Yan
XLXiufang Liu
Xiufang Liu
The Li-ion battery is of paramount importance to electric vehicles (EVs). Propelled by the rapid growth of the EV industry, the performance of the battery is continuously improving. However, Li-ion batteries are susceptible to the working temperature and only obtain the optimal performance within an acceptable temperature range. Therefore, a battery thermal management system (BTMS) is required to ensure EVs’ safe operation. There are various basic methods for BTMS, including forced-air cooling, liquid cooling, phase change material (PCM), heat pipe (HP), thermoelectric cooling (TEC), etc. Every method has its unique application condition and characteristic. Furthermore, based on basic BTMS, more hybrid cooling methods adopting different basic methods are being designed to meet EVs’ requirements. In this work, the hybrid BTMS, as a more reliable and environmentally friendly method for the EVs, will be compared with basic BTMS to reveal its advantages and potential. By analyzing its cost, efficiency and other aspects, the evaluation criterion and design suggestions are put forward to guide the future development of BTMS.

8 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
FFFan Feng
Fan Feng
ZZZe Zhang
Ze Zhang
XLXiufang Liu
Xiufang Liu
CLChanghai Liu
Changhai Liu
YHYu Hou
Yu Hou
The characteristics of the transcritical CO2 heat pump water heater (HPWH) system are; a lower inlet hot water temperature (Ti-hw) (sometimes this is lower than the water source temperature), and an outlet gas cooler temperature (To-gc) which is affected by the Ti-hw and often lower than the critical temperature. In order to study the effects of the internal heat exchanger (IHX) on the operational performance of the transcritical CO2 HPWH when To-gc is low, a transcritical CO2 water source HPWH experiment platform is established to conduct experimental research and comparative analysis on the operational performance of the transcritical CO2 water source HPWH, with or without IHX. It is found that, if only the coefficient of performance (COP) and heating at the optimal exhaust pressure of the transcritical CO2 water source HPWH were considered, COP and the heating of the non-IHX system would be slightly higher than those of the IHX system at the lower hot water flow and water source temperature, and this increase was not obvious. At the higher hot water flow rate and water source temperature, COP and the heating of the non-IHX system were also higher than those of the IHX system, and the increase was obvious. The experiment results showed that, near the optimal exhaust pressure, the variation range of COP and heating of the IHX system is relatively small, and the system has a relatively high stability.

14 June 2017 in Energies
Verified
Journal Article
Open access
PDF file
XLXiufang Liu
Xiufang Liu
CLChanghai Liu
Changhai Liu
ZZZe Zhang
Ze Zhang
LCLiang Chen
Liang Chen
YHYu Hou
Yu Hou
The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the characteristic of the S-shape isotherm at the supercritical region has little effect on the occurrence of the optimal discharge pressure; while the mass flow rate of CO2, the suction pressure and the gas-cooler outlet temperature play a significant role in determining the emergence of the optimal discharge pressure. At the optimal discharge pressure, the COP reaches the peak; however, the corresponding heating capacity is still lower than its maximum, which is reached as the discharge pressure is slightly above the optimal discharge pressure. Reducing the tap-water flowrate or increasing the water-source temperature can increase the optimal discharge pressure. The COP is positively dependent on both the tap-water flowrate and the water-source temperature. In addition, the tap-water flowrate has a negligible influence on the maximum heating capacity while increasing the water-source temperature can greatly enhance the heating capacity.

23 August 2019 in Processes
Verified
Journal Article
Open access
PDF file
RXRong Xue
Rong Xue
YRYixiao Ruan
Yixiao Ruan
XLXiufang Liu
Xiufang Liu
LCLiang Chen
Liang Chen
LLLiqiang Liu
Liqiang Liu
YHYu Hou
Yu Hou
Spray cooling with liquid nitrogen is increasingly utilized as an efficient approach to achieve cryogenic cooling. Effects of injection mass flow rate fluctuations on the evaporation, temperature distribution, and droplet distribution of a spray field were examined by employing a validated Computational Fluid Dynamics (CFD) numerical model. The numerical results indicated that injection fluctuations enhanced the volume-averaging turbulent kinetic energy and promoted the evaporation of the whole spray field. The strengthened mass and heat transfer between the liquid nitrogen droplets and the surrounding vapor created by the fluctuating injection led to a lower temperature of the whole volume. A relatively smaller droplet size and a more inhomogeneous droplet distribution were obtained under the unsteady inlet. The changes of the frequency and the amplitude of the fluctuations had little effects on the overall spray development. The results could enrich the knowledge of the relation between the inevitable fluctuations and the overall spray development and the cooling performance in a practical spray cooling system with cryogenic fluids.

5 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XLXiufang Liu
Xiufang Liu
CCChen Chen
Chen Chen
QHQian Huang
Qian Huang
SWShubei Wang
Shubei Wang
YHYu Hou
Yu Hou
LCLiang Chen
Liang Chen
The regenerator of the pulse tube refrigerator (PTR) operates with oscillating pressure and mass flow, so a proper description of the heat transfer characteristics of the oscillating flow in the regenerator is crucial. In this paper, a one-dimensional model based on Lagrangian representation is developed to simulate the oscillating flow in the regenerator of the PTR. The continuity equation, momentum equation and energy equation are solved iteratively using the SIMPLER algorithm. The Darcy-Brinkman-Forchheimer model is used in the momentum equation, and a thermal non-equilibrium model is implemented in the energy equation. Lagrangian representation is employed to describe the thermodynamics of fluid parcels while the Eulerian representation (control volume method) is adopted for the energy equation of the solid matrix. The boundary conditions are set as the periodic flow of the sine function. The thermodynamic parameters of the gas parcels are obtained, which reveal the critical processes of the heat transfer in the regenerator under oscillating flow. The performance of the regenerator with different geometries is evaluated based on the numerical results. The present study provides insight for better understanding the physical process in the regenerator of the PTR, and the proposed model serves as a useful tool for the design and optimization of the cryogenic regenerator.