We theoretically demonstrate the mechanically mediated electromagnetically induced transparency in a two-mode cavity optomechanical system, where two cavity modes are coupled to a common mechanical resonator. When the two cavity modes are driven on their respective red sidebands by two pump beams, a transparency window appears in the probe transmission spectrum due to destructive interference. Under this situation the transmitted probe beam can be delayed as much as 4 μs, which can be easily controlled by the power of the pump beams.
We theoretically investigate the light propagation in a cavity optomechanical system with a Bose-Einstein condensate (BEC). It is shown that slow light can easily be realized in this system via a BEC coupled to an optical cavity field. The numerical results further demonstrate that the transmitted probe beam from the cavity can be delayed as much as 0.8 ms by suitably selecting the pump field detuning from the cavity field frequency. The scheme proposed here may have potential applications in telecommunication and interferometry.
Directional amplifiers are crucial nonreciprocal devices in both classical and quantum information processing. Here we propose a scheme for realizing a directional amplifier between optical and microwave fields based on an optomechanical system with optical gain, where an active optical cavity and two passive microwave cavities are coupled to a common mechanical resonator via radiation pressure. The two passive cavities are coupled via hopping interaction to facilitate the directional amplification between the active and passive cavities. We obtain the condition of achieving optical directional amplification and find that the direction of amplification can be controlled by the phase differences between the effective optomechanical couplings. The effects of the gain rate of the active cavity and the effective coupling strengths on the maximum gain of the amplifier are discussed. We show that the noise added to this amplifier can be greatly suppressed in the large cooperativity limit.
We study the Fano resonance and slow light in a hybrid optomechanical system, where a mechanical resonator is coupled to a cavity via radiation pressure and to a two-level system (qubit) via the Jaynes-Cummings coupling. The absorption spectra of the weak probe field can exhibit a series of asymmetric Fano line shapes when the frequency of the strong control field varies. The positions of the double Fano resonances can be determined by the cavity–control-field detuning, the qubit-resonator coupling strength, and the transition frequency of the qubit. Furthermore, the transparency windows in the probe transmission spectrum are accompanied by the rapid normal phase dispersion, which indicates the slow light effect. We find that the group delay of the transmitted probe field can be tuned by the frequency and amplitude of the control field and is inversely proportional to the decay rate of the qubit.
We explore theoretically the bistable behavior of the intracavity photon number in a two-mode cavity optomechanical system, where two cavity modes are coupled to a common mechanical resonator. When the two cavity modes are driven by two pump laser beams, respectively, we find that the optical bistability can be controlled by tuning the power and the frequency of the pump beams. The common interaction with a mechanical mode enables one to control the bistable behavior in one cavity by adjusting the pump laser beam driving another cavity. We also show theoretically that both branches of optical bistability at photon numbers below unity can exist in this two-mode optomechanical system. This phenomenon can find potential applications in a controllable optical switch.
Nanomechanical resonators provide an unparalleled mass sensitivity sufficient to detect single biomolecules, viruses and nanoparticles. In this work we propose a scheme for mass sensing based on the hybrid opto-electromechanical system, where a mechanical resonator is coupled to an optical cavity and a microwave cavity simultaneously. When the two cavities are driven by two pump fields with proper frequencies and powers, a weak probe field is used to scan across the optical cavity resonance frequency. The mass of a single baculovirus landing onto the surface of the mechanical resonator can be measured by tracking the resonance frequency shift in the probe transmission spectrum before and after the deposition. We also propose a nonlinear mass sensor based on the measurement of the four-wave mixing (FWM) spectrum, which can be used to weigh a single 20-nm-diameter gold nanoparticle with sub-femtogram resolution.