Dynamic simulation methods have become essential in the design process and control of the catenary–pantograph system, overall since high-speed trains and interoperability criteria are getting very trendy. This paper presents an original hardware-in-the-loop (HIL) strategy aimed at integrating a multicriteria active control within the catenary–pantograph dynamic interaction. The relevance of HIL control systems applied in the frame of the pantograph is undoubtedly increasing due to the recent and more demanding requirements for high-speed railway systems. Since the loss of contact between the catenary and the pantograph leads to arcing and electrical wear, and too high contact forces cause mechanical wear of both the catenary wires and the strips of the pantograph, not only prescribed but also economic and performance criteria ratify such a relevance. Different configurations of the proportional-integral-derivative (PID) controller are proposed and applied to two different plant systems. Since this paper is mainly focused on the control strategy, both plant systems are simulation models though the methodology is suitable for a laboratory bench. The strategy of control involves a multicriteria optimisation of the contact force and the consumption of the energy supplied by the control force, a genetic algorithm has been applied for this purpose. Thus, the PID controller is fitted according to these conflicting objectives and tested within a nonlinear lumped model and a nonlinear finite element model, being the last one validated against the European Standard EN 50318. Finally, certain tests have been accomplished in order to analyse the robustness of the control strategy. Particularly, the relevance or the plant simulation, the running speed and the instrumentation time delay are studied in this paper.
Recent biomechanical studies have focused on studying the response of teeth before and after different treatments under functional and parafunctional loads. These studies often involve experimental and/or finite element analysis (FEA). Current loading and boundary conditions may not entirely represent the real condition of the tooth in clinical situations. The importance of homogenizing both sample characterization and boundary conditions definition for future dental biomechanical studies is highlighted. The mechanical properties of dental structural tissues are presented, along with the effect of functional and parafunctional loads and other environmental and biological parameters that may influence tooth survival. A range of values for Young’s modulus, Poisson ratio, compressive strength, threshold stress intensity factor and fracture toughness are provided for enamel and dentin; as well as Young’s modulus and Poisson ratio for the PDL, trabecular and cortical bone. Angles, loading magnitude and frequency are provided for functional and parafunctional loads. The environmental and physiological conditions (age, gender, tooth, humidity, etc.), that may influence tooth survival are also discussed. Oversimplifications of biomechanical models could end up in results that divert from the natural behavior of teeth. Experimental validation models with close-to-reality boundary conditions should be developed to compare the validity of simplified models.