Lei Zhang

Dr. Lei Zhang

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
QHQing-Xin Han
Qing-Xin Han
YTYi Tong
Yi Tong
LZLei Zhang
Lei Zhang
JSJin Sun
Jin Sun
JMJia Ma
Jia Ma
YLYan Li
Yan Li

4 August 2021 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
DFDingYuan Fan
DingYuan Fan
JMJia Ma
Jia Ma
LZLei Zhang
Lei Zhang
Background: The aim of anterior cruciate ligament reconstruction (ACLR) is to restore the function of the knee joint, protect the cartilage, and reduce the occurrence of osteoarthritis. However, due to the structural limitations of the human body, it is not possible to perform ACLR with conventional sutures. To restore normal functioning of the anterior cruciate ligament (ACL), a new ligament must be reconstructed in the position of the previous ACL.Objective: To compare autografts and synthetic grafts in terms of postoperative knee stability and functionSearch methods: The protocol for this study was registered with PROSPERO (CRD42021243451). Two reviewers independently searched the PubMed, Embase, and the Cochrane Library databases from database inception though February 10, 2021. The following search method was used: ((Autograft) OR (Autologous) OR (Autotransplant)) OR Artificial Ligament AND (Anterior Cruciate Ligament Injury [MeSH Terms]) AND (Randomized controlled trial [MeSH Terms]). Methodological quality was assessed by the Cochrane risk of bias tool.Selection criteria: We only included randomized controlled trials (level I) that compared autograft and synthetic graft interventions in participants with ACL injury. We included trials that evaluated ACLR using at least one outcome (Lachman test, pivot shift test, IKDC grades, or complications).Results: A total of 748 studies were identified in the initial literature search, and seven studies that examined only bone-patellar tendon-bone (BPTB) grafts compared with artificial grafts met the predetermined inclusion criteria. The results showed that BPTB grafts were associated with significantly better pivot shift test and Lachman test results and better IKDC grades and lower complication rates than synthetic grafts.Conclusions: This review indicates that for adults, BPTB grafts perform more favorably than synthetic grafts in ACLR in terms of knee stability, function, and complication. More research is needed to compare autologous tendons and allogeneic tendons with artificial ligaments, especially in elderly individuals.Level of evidence: Level I, systematic review and meta-analysis

7 April 2022 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
DFDingYuan Fan
DingYuan Fan
JMJia Ma
Jia Ma
XLXiaoHua Liu
XiaoHua Liu
LZLei Zhang
Lei Zhang
Background: As an antifibrinolytic agent, tranexamic acid (TXA) is increasingly used in total knee arthroplasty (TKA) to reduce blood loss. The administration of intravenous and intra-articular TXA has been well explored, but the most efficient way to administer TXA remains in question. Peri-articular injection (PAI) of TXA is a recently mentioned method. A meta-analysis of the efficacy of PAI TXA in patients after TKA should be performed.Methods: A systematic search was performed within PubMed, Embase, and the Cochrane Library up to November 8, 2021. Two authors independently screened studies for eligibility and extracted data for analysis. The primary outcome was haemoglobin change. The secondary outcomes were haematocrit change, total drainage volume, thromboembolic events, and blood transfusion.Results: A total of ten studies were included in this meta-analysis. The results indicated that there was a significant decrease in haemoglobin change when using PAI TXA compared with no TXA (mean difference − 1.05; 95% CI − 1.28 to − 0.81;P < 0.00001;I2 = 0%), but it had no significant differences compared with IA and IV (mean difference − 0.01; 95% CI − 0.17 to − 0.14;P = 0.85;I2 = 39%). There were no significant differences between the TXA < 1.5 g subgroup (0.10, 95% CI − 0.27 to 0.46;P = 0.60;I2 = 0%) and the TXA ≥ 1.5 g subgroup (0.18, 95% CI − 0.12 to 0.48;P = 0.24;I2 = 74%). In addition, the combined group (PAI plus IV or IA) was superior to the IV or IA group in terms of haemoglobin change (mean difference − 0.51; 95% CI − 0.76 to − 0.27;P < 0.0001;I2 = 19%). Regarding haematocrit change, the pooled result showed it was significantly less in the PAI group than the non-TXA group. Similarly, comparing it against the IV subgroup, the result revealed a difference in favour of the PAI group, with a mean difference of − 1.89 g/dL (95% CI − 2.82 to − 0.95;P < 0.0001;I2 = 67%). For total drainage volume, the pooled result was in favour of PAI TXA over no TXA (297 ml, 95% CI − 497.26 to − 97.23;P = 0.004;I2 = 87%), but it had no significant difference compared with IA and IV (mean difference − 37.98; 95% CI − 115.68 to 39.71;P = 0.34;I2 = 95%). There was no significant difference in thromboembolic events (OR 0.74; 95% CI 0.25 to 2.21;P = 0.59;I2 = 0%). Blood transfusion was not significantly different between the PAI group and the non-TXA group (OR 0.50; 95% CI 0.23 to 1.06;P = 0.07;I2 = 21%), and there was no significant difference between PAI and the other two TXA injection methods (OR 0.72; 95% CI 0.41 to 1.25;P = 0.24;I2 = 19%).Conclusion: PAI has comparable effects to IV and IA injections. PAI is an alternative injection route of TXA for patients who have undergone TKA.

1 May 2022 in Arthroscopy
Verified
Journal Article
Closed access
DFDingYuan Fan
DingYuan Fan
XLXiaoHua Liu
XiaoHua Liu
JMJia Ma
Jia Ma
SZSheng Zhang
Sheng Zhang
JSJin Sun
Jin Sun
LZLei Zhang
Lei Zhang

4 May 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TCTian-Xin Chen
Tian-Xin Chen
JWJun-Ying Wu
Jun-Ying Wu
TYTong-Jie Yang
Tong-Jie Yang
GCGang Chen
Gang Chen
YLYan Li
Yan Li
LZLei Zhang
Lei Zhang
Anterior talofibular ligament (ATFL) injuries are common ankle injuries that require accurate grading for effective treatment planning. However, conventional diagnostic methods, including manual MRI interpretation, often lack objectivity and reproducibility. Radiomics, a technique that extracts quantitative features from medical images, offers a promising solution for enhancing diagnostic precision. This study developed a radiomics model based on MRI fat-suppressed proton density-weighted turbo spin-echo images to grade ATFL injuries. A dataset of 467 arthroscopically confirmed cases (276 partial tears, 191 complete tears) was analyzed, and 28 key features were selected for model construction using machine learning classifiers. The support vector machine (SVM) model achieved the best performance, with an AUC of 0.955 (95% CI: 0.931–0.980) on the training set and 0.844 (95% CI: 0.781–0.906) on the validation set. Decision curve analysis and confusion matrix results demonstrated the model’s strong predictive accuracy and clinical utility. This SVM-based radiomics model offers a reliable, non-invasive approach for precise ATFL injury diagnosis and grading, with significant potential for improving clinical decision-making and personalized treatment.

1 November 2021 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
DFDingYuan Fan
DingYuan Fan
JMJia Ma
Jia Ma
LZLei Zhang
Lei Zhang
Tranexamic acid (TXA) reduces blood loss in knee and hip arthroplasty, but the effectiveness in shoulder arthroplasty is unknown. This study aimed to evaluate current level I randomized controlled trials examining the efficacy of TXA in primary shoulder arthroplasty. A protocol for the study was designed and registered with PROSPERO (CRD42021230398). The PubMed, Embase, and Cochrane Library databases were searched using the following search strategy: “shoulder replacement” OR “shoulder arthroplasty” OR “reverse shoulder arthroplasty” AND “tranexamic acid.” All randomized controlled trials were included in this study. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was followed. Outcomes include blood loss, drain output, hemoglobin, thromboembolic complications, and blood transfusion. Five randomized controlled trials of 435 patients (219 patients in the TXA group and 216 patients in the non-TXA group) were included in the systematic review. The results indicated that the group using TXA had less total blood loss (MD, −249.56 mL; 95% confidence interval [CI] −347.60 to −151.52), less drainage output (MD, −113.72 mL; −155.92 to −71.52 95% CI), and less of a change in hemoglobin (MD, −0.68 g/dl; −0.94 to −0.42 g/dl 95% CI). No significant differences in blood transfusion (risk ratio 0.40; −0.11 to 1.45 95% CI) or thromboembolic events (risk ratio 0.13, 0.02 to 1.12 95% CI) were observed. Subgroup analyses showed that there was no significant difference in total blood loss, drainage output, or change in hemoglobin between single dose and multiple doses. TXA in primary shoulder arthroplasty can reduce blood loss, drain output, and hemoglobin changes. Subgroup analysis showed that multiple TXA doses have similar results compared with single dose in primary shoulder arthroplasty. More randomized controlled trials comparing different administration routes of TXA in primary and revision shoulder arthroplasty are required.