Yuqiao Xiang

Mr. Yuqiao Xiang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2023 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
RFRunxin Fang
Runxin Fang
HWHao Wu
Hao Wu
YXYuqiao Xiang
Yuqiao Xiang
JMJessica Benitez Mendieta
Jessica Benitez Mendieta
ZLZhiyong Li
Zhiyong Li

9 May 2024 in IEEE Access
Verified
Journal Article
Open access
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
HWHao Wu
Hao Wu
ZZZhengduo Zhu
Zhengduo Zhu
HXHujin Xie
Hujin Xie
HYHan Yu
Han Yu
ZLZhiyong Li
Zhiyong Li
Digital Image Correlation (DIC) has been widely used as a non-contact deformation measurement technique. Nevertheless, its accuracy is greatly affected by the speckle pattern on the specimen. To systematically evaluate how speckle deformability affects the precision of DIC algorithms. In this study, a test dataset of 2D speckle patterns with various prescribed deformation fields was numerically generated, containing two categories of speckles, i.e., the deformable and the non-deformable (rigid) ones. This dataset was used to evaluate the performance of inverse compositional Gauss-Newton (ICGN)-based DIC algorithms with two types of shape function (first-order and second-order), in the different scenarios of the deformation field. The results showed that imaging noise had a significant influence on the DIC algorithm. The first-order shape function (ICGN-1) performed better when tracking the simple linear deformation field. While the second-order shape function (ICGN-2) was proved to perform better on non-linear deformations. Moreover, the deformability of the speckle was found to have an obvious impact on the performance of the DIC algorithm. ICGN-2 could effectively reduce so-called speckle rigidity induced (SRI) error. Conclusively, ICGN-2 should be chosen as priority, because of its feasibility on non-linear deformation fields and speckle rigidity. While in the linear deformation scenarios, ICGN-1 was still a robust and efficient method.

10 December 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
HXHujin Xie
Hujin Xie
HWHao Wu
Hao Wu
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
JMJessica Benitez Mendieta
Jessica Benitez Mendieta
HYHan Yu
Han Yu
ZLZhiyong Li
Zhiyong Li
Background and Objective Intracranial aneurysms are relatively common life-threatening diseases, and assessing aneurysm rupture risk and identifying the associated risk factors is essential. Parameters such as the Oscillatory Shear Index, Pressure Loss Coefficient, and Wall Shear Stress are reliable indicators of intracranial aneurysm development and rupture risk, but aneurysm surface irregular pulsation has also received attention in aneurysm rupture risk assessment. Methods: The present paper proposed a new approach to estimate aneurysm surface deformation. This method transforms the estimation of aneurysm surface deformation into a constrained optimization problem, which minimizes the error between the displacement estimated by the model and the sparse data point displacements from the four-dimensional CT angiography (4D-CTA) imaging data. Results: The effect of the number of sparse data points on the results has been discussed in both simulation and experimental results, and it shows that the proposed method can accurately estimate the surface deformation of intracranial aneurysms when using sufficient sparse data points. Conclusions: Due to a potential association between aneurysm rupture and surface irregular pulsation, the estimation of aneurysm surface deformation is needed. This paper proposed a method based on 4D-CTA imaging data, offering a novel solution for the estimation of intracranial aneurysm surface deformation.

24 November 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
YXYuqiao Xiang
Yuqiao Xiang
XHXianjue Huang
Xianjue Huang
JMJessica Benitez Mendieta
Jessica Benitez Mendieta
Jiaqiu WangJiaqiu Wang
Jiaqiu Wang
PPPhani Kumari Paritala
Phani Kumari Paritala
ZLZhiyong Li
Zhiyong Li
Degree of luminal stenosis is generally considered to be an important indicator for judging the risk of atherosclerosis burden. However, patients with the same or similar degree of stenosis may have significant differences in plaque morphology and biomechanical factors. This study investigated three patients with carotid atherosclerosis within a similar range of stenosis. Using our developed fluid–structure interaction (FSI) modelling method, this study analyzed and compared the morphological and biomechanical parameters of the three patients. Although their degrees of carotid stenosis were similar, the plaque components showed a significant difference. The distribution range of time-averaged wall shear stress (TAWSS) of patient 2 was wider than that of patient 1 and patient 3. Patient 2 also had a much smaller plaque stress compared to the other two patients. There were significant differences in TAWSS and plaque stresses among three patients. This study suggests that plaque vulnerability is not determined by a single morphological factor, but rather by the combined structure. It is necessary to transform the morphological assessment into a structural assessment of the risk of plaque rupture.