Minan Tang

Prof. Dr. Minan Tang

Lanzhou Jiaotong University, Lanzhou, Gansu, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2023 in Machines
Verified
Journal Article
Open access
PDF file
Minan TangMinan Tang
Minan Tang
YYYaguang Yan
Yaguang Yan
BABo An
Bo An
WWWenjuan Wang
Wenjuan Wang
YZYaqi Zhang
Yaqi Zhang
Parameter identification of the dynamic model of collaborative robots is the basis of the development of collaborative robot motion state control, path tracking, state monitoring, fault diagnosis, and fault tolerance systems, and is one of the core contents of collaborative robot research. Aiming at the identification of dynamic parameters of the collaborative robot, this paper proposes an identification algorithm based on weighted least squares and random weighted particle swarm optimization (WLS-RWPSO). Firstly, the dynamics mathematical model of the robot is established using the Lagrangian method, the dynamic parameters of the robot to be identified are determined, and the linear form of the dynamics model of the robot is derived taking into account the joint friction characteristics. Secondly, the weighted least squares method is used to obtain the initial solution of the parameters to be identified. Based on the traditional particle swarm optimization algorithm, a random weight particle swarm optimization algorithm is proposed for the local optimal problem to identify the dynamic parameters of the robot. Thirdly, the fifth-order Fourier series is designed as the excitation trajectory, and the original data collected by the sensor are denoised and smoothed by the Kalman filter algorithm. Finally, the experimental verification on a six-degree-of-freedom collaborative robot proves that the predicted torque obtained by the identification algorithm in this paper has a high degree of matching with the measured torque, and the established model can reflect the dynamic characteristics of the robot, effectively improving the identification accuracy.

1 January 2025 in Journal of Industrial and Management Optimization
Verified
Journal Article
Closed access
PDF file
Minan TangMinan Tang
Minan Tang
WSWenxin Sheng
Wenxin Sheng
JQJiandong Qiu
Jiandong Qiu
CZChenchen Zhang
Chenchen Zhang
HLHanting Li
Hanting Li
The forecasting of electric vehicle charging station loads is crucial for ensuring timely and feasible energy supply to achieve satisfactory charging for the relevant vehicles. Aiming at problems such as low accuracy of short-term prediction of electric vehicle charging piles, a short-term prediction method for charging a load of electric vehicle charging stations based on variational modal decomposition (VMD)-frost and ice optimisation algorithm (RIME)-bi-directional long and short term memory neural network (BiLSTM) model is proposed. Firs, in order to weaken the prediction difficulties caused by information redundancy, the optimal number of decomposition layers and penalty factors are found by RIME optimisation VMD, and the load data are decomposed into smooth IMFs as inputs. Second, in order to overcome the problem of poor neural network parameters, different components are fed into the BiLSTM prediction model optimised by the RIME algorithm to make the model robust. Finally, the public dataset of ANN-DATA in the United States and the historical load data of a charging station in Lanzhou, China are validated, and a comparison of load forecasts as well as an error analysis are performed. The results show that the model outperforms the single model and other algorithmic optimisation models in all three performance metrics on all datasets, with smaller errors and higher prediction accuracy.

8 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
Minan TangMinan Tang
Minan Tang
CWChangYou Wang
ChangYou Wang
JQJiandong Qiu
Jiandong Qiu
HLHanting Li
Hanting Li
XGXi Guo
Xi Guo
WSWenxin Sheng
Wenxin Sheng
The charging behavior of electric vehicle users is highly stochastic, which makes the short-term prediction of charging load at electric vehicle charging stations difficult. In this paper, a data-driven hybrid model optimized by the improved dung beetle optimization algorithm (IDBO) is proposed to address the problem of the low accuracy of short-term prediction. Firstly, the charging station data are preprocessed to obtain clear and organized load data, and the input feature matrix is constructed using factors such as temperature, date type, and holidays. Secondly, the optimal CNN-BiLSTM model is constructed using convolutional neural network (CNN) and Bi-directional Long Short-Term Memory (BiLSTM), which realizes the feature extraction of the input matrix and better captures the hidden patterns and regularities in it. Then, methods such as Bernoulli mapping are used to improve the DBO algorithm and its hyperparameters; for example, hidden neurons of the hybrid model are tuned to further improve the model prediction accuracy. Finally, a simulation experiment platform is established based on MATLAB R2023a to validate the example calculations on the historical data of EV charging stations in the public dataset of ANN-DATA, and comparative analyses are carried out. The results show that compared with the traditional models such as CNN, BiLSTM and PSO-CNN-BiLSTM, the coefficient of determination of the model exceeds 0.8921 and the root mean square error is maintained at about 4.413 on both the training and test sets, which proves its effectiveness and stability.

21 November 2025 in Electric Power Systems Research
Verified
Journal Article
Closed access
Minan TangMinan Tang
Minan Tang
CWChangYou Wang
ChangYou Wang
HLHanting Li
Hanting Li
XGXi Guo
Xi Guo
KZKaiyue Zhang
Kaiyue Zhang
XLXuemei Liang
Xuemei Liang

13 September 2023 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
Minan TangMinan Tang
Minan Tang
HLHang Lu
Hang Lu
BLBin Li
Bin Li
Some double-circuit transmission lines are untransposed, which results in complex coupling relations between the parameters of the transmission lines. If the traditional modal transformation matrix is directly used to decouple the parameters, it can lead to large errors in the decoupled modal parameter, errors which will be amplified in the fault location equation. Consequently, it makes the fault location results of the untransposed double-circuit transmission lines less accurate. Therefore, a new modal transformation method is needed to decouple the parameter matrix of untransposed double-circuit transmission lines and realize the fault location according to the decoupled modal parameter. By improving the basis of the Karrenbauer matrix, a modal transformation matrix suitable for decoupling parameters of untransposed double-circuit transmission lines is obtained. To address the difficulties in solving the fault location equation of untransposed double-circuit transmission lines, a new fault location method based on an improved Karrenbauer matrix and the quantum-behaved particle swarm optimization (QPSO) algorithm is proposed. Firstly, the line parameter matrix is decomposed into identical and inverse sequence components using the identical-inverse sequence component transformation. The Karrenbauer matrix is then transformed to obtain the improved Karrenbauer matrix for untransposed double-circuit transmission lines and applied to identical and inverse sequence components to solve the decoupled modal parameter. Secondly, based on the principle that voltage magnitudes at both ends are equal, the fault location equation is expressed using sequence components at each end, and the QPSO algorithm is introduced to solve the equation. Finally, the feasibility and accuracy of the proposed method are verified by PSCAD simulation. The simulation results fully demonstrate that the innovative improvement on the basis of the traditional modal transformation matrix in this paper can realize the modal transformation of the complex coupling parameters of the untransposed double-circuit transmission lines. It causes almost no errors in the decoupling process. The QPSO algorithm can also solve the fault location equation more accurately. The new fault location method can realize the accurate fault location of untransposed double-circuit transmission lines.