Amit Bhardwaj

Amit Bhardwaj


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MAMeer Juned Ali
Meer Juned Ali
ABAmit Bhardwaj
Amit Bhardwaj
MKMohammad Shoyab Khan
Mohammad Shoyab Khan
FAFarhan H. Alwadei
Farhan H. Alwadei
KGKhalid Gufran
Khalid Gufran
RARawda Alghabban
Rawda Alghabban
The current study aimed to perceive and estimate the distribution of stress generated by the forces on the maxillary anterior teeth during orthodontic retraction using the bilateral mini screw implant. Finite element models were generated from the three-dimensional (3D) reconstruction of the maxillary arch via cone–beam computed tomography (CBCT). These models imitate the retraction of maxillary anterior teeth with the mini screw placed as the skeletal anchorage. The titanium mini screw of 1.3 mm × 8 mm dimension was placed at a height of 9 mm between the first molar and second premolar on both sides of the maxilla. A nickel titanium (NiTi) coil spring of 9 mm length was attached from the mini screw implant to the power arm which generated a force of 250 gm/side. Two different power arms were placed between the lateral incisor and canine at a height of 4 mm (group 1) and 8 mm (group 2), respectively. There were no significant differences observed when the stress values were compared to the left side and the right side in group 1 with a power arm of 4 mm. In group 2, the stresses around the lateral incisors were found to be on the higher side when compared with the central incisors and canines. The length of the power arm shows no significant difference in stress distribution pattern on the left and right sides except for stresses moving from the canine region to the lateral incisor region with the increase in power arm height.

16 April 2024 in Journal of Pharmacy and Bioallied Sciences
Verified
Journal Article
Open access
ABAmit Bhardwaj
Amit Bhardwaj
KMKratika Mishra
Kratika Mishra
APAnkita Pandey
Ankita Pandey
DKDeepali Kirtiwar
Deepali Kirtiwar
AKAsmita Kharche
Asmita Kharche
PAPrashanth Agaldiviti
Prashanth Agaldiviti
The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices. Three different 3D printers were included in this study (Formlabs Form 2 3D printer; Moonray S100 printer (Sprintray, Los Angeles, CA, USA); Eden500V Stratasys 3D Printers were used to prepare orthodontic aligners with dental. The central incisors of each aligner were cut, prepared, and evaluated in terms of Martens-Hardness (HM), indentation-modulus (EIT), and elastic-index (ηIT) as per ISO14577-1:2002. Post hoc pairwise comparisons indicated no significant difference in Martens-Hardness (HM), indentation-modulus (EIT), and elastic-index (ηIT) properties in any group. Under the limitations of this study, it may be concluded that the mechanical properties of 3D-printed orthodontic aligners are dependent on the 3D printer used, and thus, differences in their clinical efficacy are anticipated.

15 November 2024 in Journal of Orofacial and Health Sciences
Verified
Journal Article
Open access
PDF file
ABAmit Bhardwaj
Amit Bhardwaj
Mechanical properties of 3D printed orthodontic aligners - JOHS- Print ISSN No: - 0976-5360 Online ISSN No:- 2229-3264 Article DOI No:- 10.18231/j.johs.2024.031, Journal of Orofacial and Health Sciences-J Orofac Health Sci