Michael Lochinvar Sim Abundo

Michael Lochinvar Sim Abundo


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
Jonathan Cabiguen PacaldoJonathan Cabiguen Pacaldo
Jonathan Cabiguen Pacaldo
PBPrincess Hope T. Bilgera
Princess Hope T. Bilgera
MAMichael Lochinvar Sim Abundo
Michael Lochinvar Sim Abundo
Electrifying off-grid and isolated islands in the Philippines remains one of the challenges that hinders community development, and one of the solutions seen to ensure energy security, energy access and promote a low-carbon future is the use of renewable energy sources. This study determines the nearshore wave energy resource during monsoon seasons in Cuyo Island using a 40-year wave hindcast and 8-year on-site wind speed data as inputs to develop a high-resolution wave energy model using SWAN and assesses its annual energy production through matching with wave energy devices. The results show that the average significant wave height (Hs), peak period (Tp) and wave power density (Pd) during a northeast monsoon are Hs = 1.35 m, Tp = 4.79 s and Pd = 4.05 kW/m, respectively, while a southwest monsoon, which is sheltered by the mainland, results in Hs = 0.52 m, Tp = 3.37 s and Pd = 0.34 kW/m. While the simulated model was observed to overestimate the significant wave height (bias = 0.398, RMSE = 0.54 and SI = 1.34), it has a strong relationship with the “observed values” (average r = 0.9). The annual energy production for Wave Dragon, Archimedes Wave Swing and Seawave Slot-Cone Generator are highest at 1970.6 MWh, 2462.04 MWh, 62.424 MWh and 4099.23 MWh, respectively.

11 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
IRIsabelo Rabuya
Isabelo Rabuya
Melissa LibresMelissa Libres
Melissa Libres
MAMichael Lochinvar Sim Abundo
Michael Lochinvar Sim Abundo
ETEvelyn Taboada
Evelyn Taboada
The multi-tier framework (MTF) of electricity access defines a continuum of electrification from tier 0, where access is inexistent or very limited, to tier 5 where access is of grid quality. Transitioning households from lower to higher tiers unlocks the potential in meeting more of their energy needs. This study investigates the transition towards higher tier electricity access on Gilutongan Island, an off-grid island of Cebu, Philippines, which is also an informal settlement community with no open land available for a centralized solar PV system. The solar PV potential of suitable rooftops on the island was determined using satellite imagery, ground measurements, and computation. The electricity demand of a cluster of 11 households was examined in detail; these households, situated near two suitable rooftops, were connected to an installed 7.92 kWp solar PV-based microgrid. Results show that the households moved up from lower to higher tier levels in all MTF attributes except for affordability. Nevertheless, the cost of a standard electricity consumption package of 1 kWh/day dropped from 18% of the average household income to 6%. Moving up on the electrification ladder to higher tier electricity access in off-grid areas is attainable with households clustered as a microgrid using rooftop solar PV. Affordability remains to be the biggest challenge that needs to be addressed.

19 October 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
Jonathan Cabiguen PacaldoJonathan Cabiguen Pacaldo
Jonathan Cabiguen Pacaldo
MAMichael Lochinvar Sim Abundo
Michael Lochinvar Sim Abundo
Electrifying off-grid and isolated islands in the Philippines remains one of the challenges that hinders community development. One of the solutions seen to ensure energy security, expand energy access and promote a low carbon future in this isolated islands is the use of renewable energy sources. This study wishes to determine the nearshore wave energy resource during monsoon seasons in Cuyo Island using a 40-year wave hindcast and 9-year on-site wind speed data to develop high resolution wave energy model using SWAN wave model, and assessed its annual energy production through matching with wave energy devices. Results shows that average significant wave height (Hs), peak period (Tp) and wave power density (Pd) during northeast monsoon are Hs = 1.35 m, Tp = 4.79 s and Pd = 4.05 kW/m respectively, while southwest monsoon which is sheltered by the mainland resulted to a lesser outcome, Hs = 0.52 m, Tp = 3.37 s and Pd = 0.34 kW/m. While the simulated model was observed to overestimate the wave energy resource (Bias = 0.398, RMSE = 0.54 and SI = 1.34), it has a strong relationship with the observed values (average r = 0.9). Its annual energy production is highest at Station 5, with AEPWaveBouy = 43.761 MWh, AEP-Pelamis = 216.786 MWh and AEPWave Dragon = 2462.66 MWh. At present, the minimum requirement for a wave energy development to be feasible is 5 kW/m, which in this case, Cuyo Island falls short, but with the continuous evolution of wave energy converters, applications on milder re-sources will soon materialized.