Peter Essig

Mr. Peter Essig

institute for ophthalmic research, Tübingen, Baden-Württemberg, Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2021 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
PEPeter Essig
Peter Essig
YSYannick Sauer
Yannick Sauer
SWSiegfried Wahl
Siegfried Wahl
Purpose: The aim of the current study was to develop and validate an automated contrast sensitivity (CS) test using a live- detection of optokinetic nystagmus (OKN) and an adaptive psychometric procedure. In addition, the study sought to replicate the known effect of defocus on CS for the OKN-based measurements in emmetropic participants. Methods: Fifteen participants viewed a horizontally moving grating while their eyes were tracked with an infra-red (IR) eye-tracker. To simulate the clinical conditions of the CS measurements, the participants were stimulated monocularly as the left eye was occluded by an IR filter. The horizontal eye position was continuously analyzed for OKN responses, and the stimulus contrast was changed by an adaptive psychometric method depending on the outcome. Furthermore, the newly proposed OKN live-detection was verified against an offline analysis and an expert-observer judgement. The OKN-based CS was measured for six spatial frequencies at normal vision and three levels of defocus using spherical convex lenses. Results: The newly proposed OKN live-detection method showed a sufficient detection performance for implementation of adaptive procedures, and the detection rate is similar or better compared to offline detection methods. Spatial frequency and defocus had a significant effect on the OKN-based CS (P < 0.0001 for both). Conclusions: The current study presents a novel method to measure motion CS in an automated way, combining the real-time detection of OKN and an adaptive psychometric procedure. Furthermore, the known effect of defocus on CS was successfully replicated with the newly developed tool. Translational Relevance: OKN-based CS is a novel approach to assess spatial vision, which is sensitive to subtle effects of defocus, allowing use with nonverbal patients and infants. Furthermore, the newly developed tool may improve the performance of such measurements.

22 February 2022 in Photonics
Verified
Journal Article
Open access
PDF file
ANAntonia Neumann
Antonia Neumann
ALAlexander Leube
Alexander Leube
NNNajma Nabawi
Najma Nabawi
YSYannick Sauer
Yannick Sauer
PEPeter Essig
Peter Essig
SWSiegfried Wahl
Siegfried Wahl
Peripheral retinal contrast reduction is suggested as a potential myopia control strategy. However, the underlying mechanism is yet unknown. Therefore, this study investigated the influence of peripheral contrast reduction on central chromatic and achromatic contrast sensitivity (CS). A total of 19 participants were included. Peripheral contrast reduction was induced via Bangerter foils of 0.4 and 0.8 density, each with a clear central zone of 8.0 mm diameter. Central achromatic and chromatic (for S-, M-, and L-cone types) CS was measured at 3 and 12 cpd in a 2-IFC psychophysical procedure. CS was tested monocularly at 0, 30, and 90 min of adaptation time, while the fellow eye was covered by an infrared filter. With the filter in place, pupil size was controlled to be smaller than the clear central aperture. Data were analyzed using linear mixed models. Cone-type CS showed significant differences among each other (all p < 0.05), except for the achromatic and L-cone type (p = 0.87). The minimum sensitivity was found with the S-cone type and the maximum with the M-cone type. Central achromatic and chromatic CS were equally affected by diffusion. The level of peripheral diffusion also influenced CS, while the 0.8 Bangerter foil led to a higher reduction in CS compared to the 0.4 Bangerter foil (p = 0.0008) and the control condition (p = 0.05). A significant reduction in CS occurred between 30 and 90 min of adaptation time (p < 0.0001). The current study found that peripheral contrast reduction impacted central achromatic and chromatic CS equally. It further showed that the amplitude of reduction was influenced by the level of diffusion, with the reduction becoming more pronounced over time.

2 May 2022 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
PEPeter Essig
Peter Essig
YSYannick Sauer
Yannick Sauer
SWSiegfried Wahl
Siegfried Wahl
Purpose: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with an established procedure of identifying the orientation of a contrast stimulus. Methods: To perform and validate the saccade-based testing, two separate measurement events were performed. In the first, participants were asked to execute a saccade toward a newly-appeared stimulus in their VF. After the saccade execution or stimulus expiry, reporting the target orientation was required in a four-alternatives forced choice (4AFC). Therefore the first measurement yields two outcomes (objective and subjective). In the second measurement, only the identification of the stimulus orientation was requested, while fixating a central mark. Stimulus contrast was controlled by an adaptive psychometric procedure in both measurements. Results: The study found strong correlations (all r ≥ 0.79) of CS values for all three possible testing methods (saccade-based responding in saccadic measurements, keyboard-based responding in saccadic measurements, keyboard-based responding in non-saccadic measurements), showing the feasibility of employment of reflexive saccades in such testing. Second, this study shows a significant influence of eccentricity and direction of the stimulus on the CS function. Conclusions: CS measured with reflexive saccades is comparable to other testing methods over several areas of the participant's VF. Hence, we propose it as a novel and objective testing procedure for CS measurements. Translational Relevance: Assessment of CS using reflexive saccades extends the portfolio of suggested eye movement-based tests, allowing objective examination across the VF, which might be helpful especially in the early detection of various eye diseases.

23 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PEPeter Essig
Peter Essig
JMJonas Müller
Jonas Müller
SWSiegfried Wahl
Siegfried Wahl
Studies on contrast sensitivity (CS) testing using optokinetic nystagmus (OKN) proposed adjusting the stimulus presentation duration based on its contrast, to increase the time efficiency of such measurement. Furthermore, stimulus-specific limits of the least OKN gain might reduce false negatives in OKN detection procedures. Therefore, we aimed to test the effects of various stimulus characteristics on OKN and to propose the stimulus-specific limits for the OKN gain and stimulus presentation duration. We tested the effect of contrast (C), spatial frequency (SF), and color on selected parameters of robust OKN response, namely its onset and offset time, amplitude, and gain. The right eyes of fifteen emmetropes were tracked with an infrared eye tracker during monocular observations of sinusoidal gratings moving over the horizontal plane with a velocity of (21∘/s). The available contrast levels were C: 0.5%, 2.0%, 8.2%, 16.5%, 33.0%, and 55.5% presented in a random order for ten times in all measurements of SF: 0.12, 0.25, 0.5, and 1.00 cycles per degree and grating type: luminance, red-green, and blue-yellow. This study showed a significant effect of the stimulus characteristics on the OKN onset, offset and gain. The effect of SF was insignificant in OKN amplitude; however, it indicated significance for the C and grating type. Furthermore, the OKN gain and offset limits were proposed as functions of contrast for the luminance and chromatic gratings. This study concludes the characteristics of a visual stimulus have an effect on the OKN gain and onset and offset time, yet do not affect the eye-movement amplitude considerably. Moreover, the proposed limits are expected to improve the time efficiency and eye-movement detection in OKN-based contrast sensitivity measurements.