Alessandro Marchese

Dr. Alessandro Marchese

IRCCS Ospedale San Raffaele, Milan, Italy

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2018 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
MCMaria Vittoria Cicinelli
Maria Vittoria Cicinelli
AMAlessandro Marchese
Alessandro Marchese
Francesco BandelloFrancesco Bandello
Francesco Bandello
GMGiulio Modorati
Giulio Modorati
Ocular surface squamous neoplasia (OSSN) is the most common non-pigmented malignancy of the ocular surface and is represented in a wide range of histologic diagnoses, ranging from mild epithelial dysplasia to invasive squamous carcinoma. Although surgical excision is still the gold standard for OSSN treatment, interest in conservative medical approaches is steadily growing. We have reviewed all of the literature on OSSN published in English in the MEDLINE database up to May 2018, using the keywords “ocular surface squamous neoplasia,” “squamous conjunctival carcinoma,” and “conjunctival carcinoma in situ,” with the aim to provide a comprehensive review of the most recent evidence on this distinct clinical entity.

5 January 2017 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
MCMaria Vittoria Cicinelli
Maria Vittoria Cicinelli
ARAlessandro Rabiolo
Alessandro Rabiolo
AMAlessandro Marchese
Alessandro Marchese
LVLuigi Antonio De Vitis
Luigi Antonio De Vitis
ACAdriano Carnevali
Adriano Carnevali
GQGiuseppe Querques
Giuseppe Querques
Aims To describe the vascular changes in patients affected by non-neovascular age-related macular degeneration (AMD), featuring reticular pseudodrusen (RPD), drusen, or both RPD and drusen by means of optical coherence tomography angiography (OCT-A). Methods Cross-sectional observational case series. Patients with non-neovascular AMD presenting at the Medical Retina Service of the Department of Ophthalmology, University Vita-Salute San Raffaele in Milan were recruited. Patients underwent best-corrected visual acuity, biomicroscopy, infrared reflectance, short-wavelength fundus autofluorescence and OCT-A (AngioPlex, CIRRUS HD-OCT 5000, Carl Zeiss Meditech, Dublin, USA). Main outcome was quantification of vessel density, stromal tissue, and vascular/stromal (V/S) ratio at the choriocapillaris (CC), the Sattler and Haller's and the whole choroid layers among different groups of patients with non-neovascular AMD by means of binarised OCT-A scans. Results 45 eyes of 34 patients were enrolled (15 eyes of 11 patients with RPD, group 1; 15 eyes of 11 patients with drusen, group 2; 15 eyes of 12 patients with mixed phenotype, group 3). The CC, the Sattler and Haller's and the whole choroid vessel density were reduced in all groups of patients (p=0.023, p=0.007 and p=0.011 in group 1, group 2 and group 3 for the CC; p=0.021, p=0.037 and p=0.043 in group 1, group 2 and group 3 for the Sattler and Haller's density; p=0.016, p=0.002 and p<0.001 in group 1, group 2 and group 3 for the choroidal density), with significantly lower V/S ratios compared with healthy controls. Conclusions Patients with non-neovascular AMD show significant choroidal vascular depletion and fibrotic replacement, suggesting a possible role in the pathogenesis and progression of the disease.

1 April 2020 in Ophthalmology Retina
Verified
Journal Article
Closed access
MCMaria Vittoria Cicinelli
Maria Vittoria Cicinelli
CGChiara Giuffré
Chiara Giuffré
AMAlessandro Marchese
Alessandro Marchese
LJLee M. Jampol
Lee M. Jampol
UIUgo Introini
Ugo Introini
GMGiulio Maria Modorati
Giulio Maria Modorati

1 September 2017 in Retina
Verified
Journal Article
Closed access
PDF file
CSCarlo La Spina
Carlo La Spina
ACAdriano Carnevali
Adriano Carnevali
AMAlessandro Marchese
Alessandro Marchese
GQGiuseppe Querques
Giuseppe Querques
Francesco BandelloFrancesco Bandello
Francesco Bandello
Purpose: Optical coherence tomography angiography (OCTA) allows delineating the foveal avascular zone (FAZ) easily and noninvasively. The present study aims to test reproducibility and reliability of FAZ evaluation by means of OCTA in different settings. Methods: Twenty-four eyes of 24 normal subjects were investigated using AngioVue OCTA Imaging System. A series of OCTA acquisitions were taken both in basal and in different experimental settings after vasoactive stimuli. Images were evaluated separately by two operators and FAZ area was measured both manually and using the built-in automated measurement tool. Results: No differences for FAZ area were found in the repetition of basal acquisitions, neither in manual nor in automated measurement (0.215 ± 0.06 vs. 0.216 ± 0.07, and 0.268 ± 0.05 vs. 0.264 ± 0.09, first vs. second basal measurement in square millimetres for manual and automated evaluation, P = 0.25 and P = 0.35, respectively). Interoperators correlation was optimal (r2 = 0.978 [95% CI 0.981–0.976]). No differences were found among the other settings, which included first basal and then repeated (second) in the morning, after flickering light stimulus, after a Bruce treadmill stress test, after 30 minutes dark adaptation, and basal in the evening, neither in automated nor in manual measurements. Automated measurements for nonflow areas provided significantly larger diameters than manual ones. Conclusion: AngioVue OCTA Imaging System produces highly reproducible FAZ images with a high interoperators concordance level. Optical coherence tomography angiography capability to detect FAZ area seems not to be influenced by any of the vasoactive stimuli considered in the current study. Nonflow areas seem to be larger when measured automatically than manually.

1 January 2018 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
ARAlessandro Rabiolo
Alessandro Rabiolo
FGFrancesco Gelormini
Francesco Gelormini
AMAlessandro Marchese
Alessandro Marchese
MCMaria Vittoria Cicinelli
Maria Vittoria Cicinelli
GTGiacinto Triolo
Giacinto Triolo
GQGiuseppe Querques
Giuseppe Querques
Purpose: To investigate the macular quantitative parameters interchangeability of three different optical coherence tomography angiography (OCT-A) angiocubes (i.e., 3 × 3, 6 × 6, and 12 × 12 mm) on healthy subjects and patients affected by diabetic retinopathy (DR) and to assess the interrater reliability of such indices across the different scan protocols. Methods: Retrospective study involving 20 eyes of healthy subjects and 20 eyes with DR. All eyes underwent swept-source OCT-A with 3 × 3-, 6 × 6-, and 12 × 12-mm angiocubes centered on the fovea. Foveal avascular zone (FAZ) area and vessel density on 3 × 3-, 6 × 6-, and 12 × 12-mm macular scans were calculated by three independent operators at all retina, superficial, deep, and choriocapillary vascular layers. Interchangeability and interrater reliabilities were estimated using intraclass correlation coefficient (ICC). Results: Interscan reproducibility of FAZ area was very strong (ICC > 0.85) at every plexus. On the contrary, vessel density values significantly varied across different scan sizes (ICC < 0.51). Intrascan interrater reliability was high for all retina and superficial FAZ areas, while it was satisfactory at deep capillary plexus only for 3 × 3-mm scan. Conclusions: FAZ area at all plexuses is a robust parameter even if calculated on angiocubes with different size. However, interrater reliability is higher when measured in smaller scans. Conversely, vessel density results depend on the size of angiocube, although their interrater reliability is extremely high. Studies involving OCT-A should take into consideration that scan size may influence macular perfusion parameters and interrater reliability.

1 September 2018 in Ophthalmology Retina
Verified
Journal Article
Closed access
ACAdriano Carnevali
Adriano Carnevali
RSRiccardo Sacconi
Riccardo Sacconi
LQLea Querques
Lea Querques
AMAlessandro Marchese
Alessandro Marchese
VCVittorio Capuano
Vittorio Capuano
GQGiuseppe Querques
Giuseppe Querques