Mehmet Selim Hanay

Mehmet Selim Hanay

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2009 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
ANA. K. Naik
A. K. Naik
MHMehmet Selim Hanay
Mehmet Selim Hanay
WHW. K. Hiebert
W. K. Hiebert
XFX. L. Feng
X. L. Feng
MRM. L. Roukes
M. L. Roukes
Mass spectrometry provides rapid and quantitative identification of protein species with relatively low sample consumption. The trend towards biological analysis at increasingly smaller scales, ultimately down to the volume of an individual cell, continues, and mass spectrometry with a sensitivity of a few to single molecules will be necessary. Nanoelectromechanical systems provide unparalleled mass sensitivity, which is now sufficient for the detection of individual molecular species in real time. Here, we report the first demonstration of mass spectrometry based on single biological molecule detection with a nanoelectromechanical system. In our nanoelectromechanical–mass spectrometry system, nanoparticles and protein species are introduced by electrospray injection from the fluid phase in ambient conditions into vacuum, and are subsequently delivered to the nanoelectromechanical system detector by hexapole ion optics. Precipitous frequency shifts, proportional to the mass, are recorded in real time as analytes adsorb, one by one, onto a phase-locked, ultrahigh-frequency nanoelectromechanical resonator. These first nanoelectromechanical system–mass spectrometry spectra, obtained with modest mass sensitivity from only several hundred mass adsorption events, presage the future capabilities of this approach. We also outline the substantial improvements that are feasible in the near term, some of which are unique to nanoelectromechanical system based-mass spectrometry.

26 August 2012 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
MHMehmet Selim Hanay
Mehmet Selim Hanay
SKS. Kelber
S. Kelber
ANA. K. Naik
A. K. Naik
DCD. Chi
D. Chi
SHS. Hentz
S. Hentz
MRM. L. Roukes
M. L. Roukes
Nanoelectromechanical systems (NEMS) resonators can detect mass with exceptional sensitivity. Previously, mass spectra from several hundred adsorption events were assembled in NEMS-based mass spectrometry using statistical analysis. Here, we report the first realization of single-molecule NEMS-based mass spectrometry in real time. As each molecule in the sample adsorbs on the resonator, its mass and position of adsorption are determined by continuously tracking two driven vibrational modes of the device. We demonstrate the potential of multimode NEMS-based mass spectrometry by analysing IgM antibody complexes in real time. NEMS-based mass spectrometry is a unique and promising new form of mass spectrometry: it can resolve neutral species, provide a resolving power that increases markedly for very large masses, and allow the acquisition of spectra, molecule-by-molecule, in real time.

30 March 2015 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
MHMehmet Selim Hanay
Mehmet Selim Hanay
SKScott I. Kelber
Scott I. Kelber
COCathal D. O'Connell
Cathal D. O'Connell
PMPaul Mulvaney
Paul Mulvaney
JSJohn E. Sader
John E. Sader
MRMichael L. Roukes
Michael L. Roukes

10 March 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
ESEric Sage
Eric Sage
ABAriel Brenac
Ariel Brenac
TAThomas Alava
Thomas Alava
RMRobert Morel
Robert Morel
CDCécilia Dupré
Cécilia Dupré
SHSébastien Hentz
Sébastien Hentz
Current approaches to mass spectrometry (MS) require ionization of the analytes of interest. For high-mass species, the resulting charge state distribution can be complex and difficult to interpret correctly. Here, using a setup comprising both conventional time-of-flight MS (TOF-MS) and nano-electromechanical systems-based MS (NEMS-MS) in situ, we show directly that NEMS-MS analysis is insensitive to charge state: the spectrum consists of a single peak whatever the species’ charge state, making it significantly clearer than existing MS analysis. In subsequent tests, all the charged particles are electrostatically removed from the beam, and unlike TOF-MS, NEMS-MS can still measure masses. This demonstrates the possibility to measure mass spectra for neutral particles. Thus, it is possible to envisage MS-based studies of analytes that are incompatible with current ionization techniques and the way is now open for the development of cutting-edge system architectures with unique analytical capability.

25 January 2018 in Nano Letters
Verified
Journal Article
Closed access
JSJohn Elie Sader
John Elie Sader
MHMehmet Selim Hanay
Mehmet Selim Hanay
ANAdam P. Neumann
Adam P. Neumann
MRMichael Lee Roukes
Michael Lee Roukes

21 October 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ADAlper Demir
Alper Demir
MHMehmet Selim Hanay
Mehmet Selim Hanay