Analogues of palytoxin (PLTX), one of the most potent marine biotoxins, are produced by some species of the marine dinoflagellates of the genus Ostreopsis. The proliferation of these species in different coastal zones represents a potential threat of seafood poisoning in humans because the produced toxins can be transferred through marine food webs. Thus, the determination of the concentration of PLTX analogues (ovatoxins—OVTXs, ostreocins—OSTs and isobaric PLTX) in different matrices (seawater, marine fauna, etc.) is necessary to protect human health. This study is addressed to overcome some of the challenges that the chemical complexity of these molecules poses to their quantification by ultra-high-performance liquid chromatography high-resolution mass spectrometry-based techniques (UHPLC-HRMS). In particular, the mass spectra of the palytoxin analogues show the presence of a large number of ions (including mono- and multiply charged ions) whose nature, relative abundances and behavior can lead to quantitation errors if the correct ions are not selected. In this work, the variability of the PLTX and OVTX profiles under different instrument conditions, including the use of diverse electrospray generation sources and different quantitation methods, is studied. Moreover, the extraction protocol in seawater containing Ostreopsis sp. ovata cells is also evaluated. The use of a heated electrospray operating at 350 °C and a quantitative method including ions from different multiply charged species provides a more robust and reliable method for overcoming the problems due to the variability in the toxin's mass spectrum profile. A single MeOH : H2O (80 : 20, v/v) extraction is proposed as the best and reliable procedure. The overall method proposed was applied to quantify OVTXs (-a to -g) and iso-PLTX along the 2019 Ostreopsis cf. ovata bloom. The cells contained a total toxin concentration of up to 20.39 pg per cell.
This study aimed to improve the understanding of the nutrient modulation of Ostreopsis cf. ovata toxin content. During the 2018 natural bloom in the NW Mediterranean, the total toxin content (up to ca. 57.6 ± 7.0 pg toxin cell−1) varied markedly. The highest values often coincided with elevated O. cf. ovata cell abundance and with low inorganic nutrient concentrations. The first culture experiment with a strain isolated from that bloom showed that cell toxin content was higher in the stationary than in the exponential phase of the cultures; phosphate- and nitrate-deficient cells exhibited similar cell toxin variability patterns. The second experiment with different conditions of nitrogen concentration and source (nitrate, urea, ammonium, and fertilizer) presented the highest cellular toxin content in the high-nitrogen cultures; among these, urea induced a significantly lower cellular toxin content than the other nutrient sources. Under both high- and low-nitrogen concentrations, cell toxin content was also higher in the stationary than in the exponential phase. The toxin profile of the field and cultured cells included ovatoxin (OVTX) analogues -a to -g and isobaric PLTX (isoPLTX). OVTX-a and -b were dominant while OVTX-f, -g, and isoPLTX contributed less than 1-2%. Overall, the data suggest that although nutrients determine the intensity of the O. cf. ovata bloom, the relationship of major nutrient concentrations, sources and stoichiometry with cellular toxin production is not straightforward.
16 October 2025 in Analytical and Bioanalytical Chemistry
Palytoxin (PLTX) and its analogues from Ostreopsis cf. ovata are significant health concerns. They show potent vasoconstrictive properties, often causing seafood poisoning. PLTX analogues have chiral centers, resulting in many isomers, making their separation by liquid chromatography and identification/characterization by mass spectrometry challenging. This study explores for the first time the ion mobility spectrometry (IMS) behavior of these compounds to address these analytical challenges. Drift tube ion mobility spectrometry (DTIMS) and traveling wave ion mobility spectrometry (TWIMS) were used and compared. Additionally, trapped ion mobility spectrometry (TIMS) and molecular dynamics simulation were employed to explain unexpected results. TIMS provided higher resolution, distinguishing isomeric ions generated in the electrospray source by losing water molecules from different toxin sites. Computational studies offered theoretical insights into the ion mobility of triply charged calcium and sodium adduct ions, suggesting a folded conformation. DT CCS N2 (collisional cross section using DTIMS and nitrogen as buffer gas) values were obtained for PLTX (standard), ovatoxin-a, and ovatoxin-b from microalgae samples in Sant Andreu de Llavaneres (Barcelona, Spain). These values were comparable (ΔCCSs < 2%) to those measured with TWIMS calibrated using PLTX (standard). The study provides 102 CCS values from DTIMS and TWIMS data for adducts and fragment ions of PLTX analogues, which can be used as reference values in databases for toxin screening in complex samples. Graphical Abstract