Wei Wang

Mr. Wei Wang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
DQDui Qin
Dui Qin
QZQingqin Zou
Qingqin Zou
SLShuang Lei
Shuang Lei
WWWei Wang
Wei Wang
ZLZhangyong Li
Zhangyong Li
Encapsulated microbubbles combined with ultrasound have been widely utilized in various biomedical applications; however, the bubble dynamics in viscoelastic medium have not been completely understood. It involves complex interactions of coated microbubbles with ultrasound, nearby microbubbles and surrounding medium. Here, a comprehensive model capable of simulating the complex bubble dynamics was developed via taking the nonlinear viscoelastic behaviors of the shells, the bubble–bubble interactions and the viscoelasticity of the surrounding medium into account simultaneously. For two interacting lipid-coated bubbles with different initial radii in viscoelastic media, it exemplified that the encapsulating shell, the inter-bubble interactions and the medium viscoelasticity would noticeably suppress bubble oscillations. The inter-bubble interactions exerted a much stronger suppressing effect on the small bubble within the parameters examined in this paper, which might result from a larger radiated pressure acting on the small bubble due to the inter-bubble interactions. The lipid shells make the microbubbles exhibit two typical asymmetric dynamic behaviors (i.e., compression or expansion dominated oscillations), which are determined by the initial surface tension of the bubbles. Accordingly, the inertial cavitation threshold decreases as the initial surface tension increases, but increases as the shell elasticity and viscosity increases. Moreover, with the distance between bubbles decreasing and/or the initial radius of the large bubble increasing, the oscillations of the small bubble decrease and the inertial cavitation threshold increases gradually due to the stronger suppression effects caused by the enhanced bubble–bubble interactions. Additionally, increasing the elasticity and/or viscosity of the surrounding medium would also dampen bubble oscillations and result in a significant increase in the inertial cavitation threshold. This study may contribute to both encapsulated microbubble-associated ultrasound diagnostic and emerging therapeutic applications.

27 May 2023 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
DQDui Qin
Dui Qin
SLShuang Lei
Shuang Lei
BCBo Chen
Bo Chen
ZLZhangyong Li
Zhangyong Li
WWWei Wang
Wei Wang
XJxiaojuan ji
xiaojuan ji
The cavitation dynamics of an air-vapor mixture bubble with ultrasonic excitation can be greatly affected by the equation of state (EOS) for the interior gases. To simulate the cavitation dynamics, the Gilmore-Akulichev equation was coupled with the Peng-Robinson (PR) EOS or the Van der Waals (vdW) EOS. In this study, the thermodynamic properties of air and water vapor predicted by the PR and vdW EOS were first compared, and the results showed that the PR EOS gives a more accurate estimation of the gases within the bubble due to the less deviation from the experimental values. Moreover, the acoustic cavitation characteristics predicted by the Gilmore-PR model were compared to the Gilmore-vdW model, including the bubble collapse strength, the temperature, pressure and number of water molecules within the bubble. The results indicated that a stronger bubble collapse was predicted by the Gilmore-PR model rather than the Gilmore-vdW model, with higher temperature and pressure, as well as more water molecules within the collapsing bubble. More importantly, it was found that the differences between both models increase at higher ultrasound amplitudes or lower ultrasound frequencies while decreasing as the initial bubble radius and the liquid parameters (e.g., surface tension, viscosity and temperature of the surrounding liquid) increase. This study might offer important insights into the effects of the EOS for interior gases on the cavitation bubble dynamics and the resultant acoustic cavitation-associated effects, contributing to further optimization of its applications in sonochemistry and biomedicine.

1 January 2022 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
XLXinwei Li
Xinwei Li
JTJia Tan
Jia Tan
PWPanyu Wang
Panyu Wang
HLHong Liu
Hong Liu
ZLZhangyong Li
Zhangyong Li
WWWei Wang
Wei Wang

15 August 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
XLXinwei Li
Xinwei Li
LWLinjin Wang
Linjin Wang
HLHong Liu
Hong Liu
BMBaoqiang Ma
Baoqiang Ma
LCLei Chu
Lei Chu
SLShuyu Li
Shuyu Li
Precise delineation of hippocampus subfields is crucial for the identification and management of various neurological and psychiatric disorders. However, segmenting these subfields automatically in routine 3 T MRI is challenging due to their complex morphology and small size, as well as the limited signal contrast and resolution of the 3 T images. This research proposes Syn_SegNet, an end-to-end, multitask joint deep neural network that leverages ultrahigh-field 7 T MRI synthesis to improve hippocampal subfield segmentation in 3 T MRI. Our approach involves two key components. First, we employ a modified Pix2PixGAN as the synthesis model, incorporating self-attention modules, image and feature matching loss, and ROI loss to generate high-quality 7T-like MRI around the hippocampal region. Second, we utilize a variant of 3D-U-Net with multiscale deep supervision as the segmentation subnetwork, incorporating an anatomic weighted cross-entropy loss that capitalizes on prior anatomical knowledge. We evaluate our method on hippocampal subfield segmentation in paired 3 T MRI and 7 T MRI with seven different anatomical structures. The experimental findings demonstrate that Syn_SegNet's segmentation performance benefits from integrating synthetic 7 T data in an online manner and is superior to competing methods. Furthermore, we assess the generalizability of the proposed approach using a publicly accessible 3 T MRI dataset. The developed method would be an efficient tool for segmenting hippocampal subfields in routine clinical 3 T MRI.

21 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CJchao jiang
chao jiang
YYYan Yang
Yan Yang
HMHuayun Mao
Huayun Mao
DYDewei Yang
Dewei Yang
WWWei Wang
Wei Wang
The inertial measurement unit (IMU)-to-segment (I2S) alignment is an important part of IMU-based joint angle estimation, and the accurate estimation of the three degree of freedom (3-DOF) knee angle can provide practical support for the evaluation of motions. In this paper, we introduce a dynamic weight particle swarm optimization (DPSO) algorithm with crossover factor based on the joint constraint to obtain the dynamic alignment vectors of I2S, and use them to perform the quaternion-based 3-DOF knee angle estimation algorithm. The optimization algorithm and the joint angle estimation algorithm were evaluated by comparing with the optical motion capture system. The range of 3-DOF knee angle root mean square errors (RMSEs) is 1.6°–5.9° during different motions. Furthermore, we also set up experiments of human walking (3 km/h), jogging (6 km/h) and ordinary running (9 km/h) to investigate the effects of dynamic I2S misalignment errors on 3-DOF knee angle estimation during different motions by artificially adding errors to I2S alignment parameters. The results showed differences in the effects of I2S misalignment errors on the estimation of knee abduction, internal rotation and flexion, which indicate the differences in knee joint kinematics among different motions. The IMU to thigh misalignment error has the greatest effect on the estimation of knee internal rotation. The effect of IMU to thigh misalignment error on the estimation of knee abduction angle becomes smaller and then larger during the two processes of switching from walking to jogging and then speeding up to ordinary running. The effect of IMU to shank misalignment error on the estimation of knee flexion angle is numerically the largest, while the standard deviation (SD) is the smallest. This study can provide support for future research on the accuracy of 3-DOF knee angle estimation during different motions.

12 September 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MLMinchuan Li
Minchuan Li
PRPeng Ran
Peng Ran
YZYing Zhong
Ying Zhong
ZJZhuizhui Jiao
Zhuizhui Jiao
WLWei Liu
Wei Liu
WWWei Wang
Wei Wang
In this study, we focused on addressing the challenges existing in diagnostic techniques for esophageal motility dysfunction, specifically addressing the limitations of high-resolution manometry (HRM) and luminal functional imaging probes (FLIP). We designed an innovative balloon catheter structure based on a flexible piezoelectric sensor array for esophageal motility detection and simulated the swallowing process on an isolated porcine esophageal tube, resulting in precise monitoring of pressure changes at key points of the esophagus. The experimental results reveal the effectiveness of the sensor system in monitoring the pressure changes at key points of the esophagus, showing good accuracy and sensitivity. In this study, the performance of the sensor system under different environmental conditions is explored in depth by combining simulation, analytical calculation and physical experiments. The application of finite element simulation and feature analysis successfully established the direct relationship between the esophageal pressure and the sensor output, and realized the accurate reconstruction of the esophageal peristaltic wave pressure. At the theoretical and experimental level, the analysis of the sensor unit verifies its efficient response to resting and principal characteristic peristaltic waves. The spatial and temporal distribution of the sensor output is highly consistent with the distribution of the simulated peristaltic wave load. In addition, we further evaluated the overall performance of the system, especially the sensing ability under different liquid filling conditions and the feasibility of the reconstruction calculation method, through a meticulous error analysis of the reconstruction reconstruction results and the peristaltic wave input of the simulated swallowing esophagus.