Hong Cai

Dr. Hong Cai


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2019 in Der Unfallchirurg
Verified
Journal Article
Open access
PDF file
CFChristian Fang
Christian Fang
HCHong Cai
Hong Cai
EKEvelyn Kuong
Evelyn Kuong
ECElvis Chun Sing Chui
Elvis Chun Sing Chui
YSYuk Chuen Siu
Yuk Chuen Siu
Igor DrstvensekIgor Drstvensek
Igor Drstvensek
There are numerous orthopaedic applications of three-dimensional (3D) printing for the pelvis and acetabulum. The authors reviewed recently published articles and summarized their experience. 3D printed anatomical models are particularly useful in pelvic and acetabular fracture surgery for planning, implant templating and for anatomical assessment of pathologies such as CAM-type femoroacetabular impingement and rare deformities. Custom-made metal 3D printed patient-specific implants and instruments are increasingly being studied for pelvic oncologic resection and reconstruction of resected defects as well as for revision hip arthroplasties with favourable results. This article also discusses cost-effectiveness considerations when preparing pelvic 3D printed models from a hospital 3D printing centre.

11 March 2015 in Advanced Engineering Materials
Verified
Journal Article
Closed access
PDF file
JLJia Lv
Jia Lv
ZJZhaojun Jia
Zhaojun Jia
JLJing Li
Jing Li
YWYanen Wang
Yanen Wang
JYJun Yang
Jun Yang
ZLZhongjun Liu
Zhongjun Liu

1 December 2021 in Bioactive Materials
Verified
Journal Article
Open access
ZJZehao Jing
Zehao Jing
RNRenhua Ni
Renhua Ni
JWJiedong Wang
Jiedong Wang
XLXinhong Lin
Xinhong Lin
DFDaoyang Fan
Daoyang Fan
ZLZhongjun Liu
Zhongjun Liu
Surgical resection and perioperative adjuvant chemotherapy-based therapies have improved the prognosis of patients with osteosarcoma; however, intraoperative bone defects, local tumour recurrence, and chemotherapy-induced adverse effects still affect the quality of life of patients. Emerging 3D-printed titanium alloy (Ti6Al4V) implants have advantages over traditional implants in bone repair, including lower elastic modulus, lower stiffness, better bone conduction, more bone in-growth, stronger mechanical interlocking, and lager drug-loading capacity by their inherent porous structure. Here, cisplatin, a clinical first-line anti-osteosarcoma drug, was loaded into Ti6Al4V implants, within a PLGA-PEG-PLGA thermo-sensitive hydrogel, to construct bone substitutes with both anti-osteosarcoma and bone-repair functions. The optimal concentrations of cisplatin (0.8 and 1.6 mg/mL) were first determined in vitro. Thereafter, the anti-tumour effect and biosafety of the cisplatin/hydrogel-loaded implants, as well as their bone-repair potential were evaluated in vivo in tumour-bearing mouse, and bone defect rabbit models, respectively. The loading of cisplatin reduced tumour volume by more than two-thirds (from 641.1 to 201.4 mm3) with negligible organ damage, achieving better anti-tumour effects while avoiding the adverse effects of systemic cisplatin delivery. Although bone repair was hindered by cisplatin loading at 4 weeks, no difference was observed at 8 weeks in the context of implants with versus without cisplatin, indicating acceptable long-term stability of all implants (with 8.48%–10.04% bone in-growth and 16.94%–20.53% osseointegration). Overall, cisplatin/hydrogel-loaded 3D-printed Ti6Al4V implants are safe and effective for treating osteosarcoma-caused bone defects, and should be considered for clinical use.

1 March 2024 in Bioactive Materials
Verified
Journal Article
Open access
ZJZehao Jing
Zehao Jing
WYWanqiong Yuan
Wanqiong Yuan
JWJiedong Wang
Jiedong Wang
RNRenhua Ni
Renhua Ni
YQYu Qin
Yu Qin
ZLZhongjun Liu
Zhongjun Liu
Postoperative anatomical reconstruction and prevention of local recurrence after tumor resection are two vital clinical challenges in osteosarcoma treatment. A three-dimensional (3D)-printed porous Ti6Al4V scaffold (3DTi) is an ideal material for reconstructing critical bone defects with numerous advantages over traditional implants, including a lower elasticity modulus, stronger bone-implant interlock, and larger drug-loading space. Simvastatin is a multitarget drug with anti-tumor and osteogenic potential; however, its efficiency is unsatisfactory when delivered systematically. Here, simvastatin was loaded into a 3DTi using a thermosensitive poly (lactic-co-glycolic) acid (PLGA)-polyethylene glycol (PEG)-PLGA hydrogel as a carrier to exert anti-osteosarcoma and osteogenic effects. Newly constructed simvastatin/hydrogel-loaded 3DTi (Sim-3DTi) was comprehensively appraised, and its newfound anti-osteosarcoma mechanism was explained. Specifically, in a bone defect model of rabbit condyles, Sim-3DTi exhibited enhanced osteogenesis, bone in-growth, and osseointegration compared with 3DTi alone, with greater bone morphogenetic protein 2 expression. In our nude mice model, simvastatin loading reduced tumor volume by 59%–77 % without organic damage, implying good anti-osteosarcoma activity and biosafety. Furthermore, Sim-3DTi induced ferroptosis by upregulating transferrin and nicotinamide adenine dinucleotide phosphate oxidase 2 levels in osteosarcoma both in vivo and in vitro. Sim-3DTi is a promising osteogenic bone substitute for osteosarcoma-related bone defects, with a ferroptosis-mediated anti-osteosarcoma effect.

30 April 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JYJun Yang
Jun Yang
HCHong Cai
Hong Cai
JLJia Lv
Jia Lv
KZKe Zhang
Ke Zhang
HLHuijie Leng
Huijie Leng
ZLZhongjun Liu
Zhongjun Liu
Various fabrication methods are used to improve the stability and osseointegration of screws within the host bone. The aim of this study was to investigate whether roughened surface titanium screws fabricated by electron beam melting can provide better stability and osseointegration as compared with smooth titanium screws in sheep cervical vertebrae. Roughened surface titanium screws, fabricated by electron beam melting, and conventional smooth surface titanium screws were implanted into sheep for 6 or 12 weeks (groups A and B, respectively). Bone ingrowth and implant stability were assessed with three-dimensional imaging and reconstruction, as well as histological and biomechanical tests. No screws in either group showed signs of loosening. Fibrous tissue formation could be seen around the screws at 6 weeks, which was replaced with bone at 12 weeks. Bone volume/total volume, bone surface area/bone volume, and the trabecular number were significantly higher for a define region of interest surrounding the roughened screws than that surrounding the smooth screws at 12 weeks. Indeed, for roughened screws, trabecular number was significantly higher at 12 weeks than at 6 weeks. On mechanical testing, the maximum pullout strength was significantly higher at 12 weeks than at 6 weeks, as expected; however, no significant differences were found between smooth and roughened screws at either time point. The maximum torque to extract the roughened screws was higher than that required for the smooth screws. Electron beam melting is a simple and effective method for producing a roughened surface on titanium screws. After 12 weeks, roughened titanium screws demonstrated a high degree of osseointegration and increased torsional resistance to extraction over smooth titanium screws.

5 August 2023 in Arthroplasty
Verified
Journal Article
Open access
PDF file
ZYZhenguo Yu
Zhenguo Yu
HCHong Cai
Hong Cai
ZLZhongjun Liu
Zhongjun Liu
Abnormal retro patellar stress is believed to contribute to patellofemoral complications after total knee arthroplasty (TKA), but the causal link between TKA and patellofemoral contact stress remains unclear. By reviewing the relevant studies, we found that both TKA implantation and additional patellar resurfacing increase retro patellar pressure. The rotation and size of the femoral component, thickness and position of the patellar component, installation of the tibial component, prosthesis design and soft tissue balance further influence patellofemoral stress. Specific measures can be applied to reduce stress, including the installation of the femoral prosthesis with an appropriate external rotation angle, placing the tibial component at a more posterior position and the patellar button at a more medial position, avoiding over-sized femoral and patellar components, selecting posterior-stabilized design rather than cruciate-retaining design, using gender-specific prosthesis or mobile-bearing TKA system, and releasing the lateral retinaculum or performing partial lateral facetectomy. Despite these measures, the principle of individualization should be followed to optimize the patellofemoral biomechanics.