Periprosthetic osteolysis remains a leading complication of total hip and knee arthroplasty, often resulting in aseptic loosening of the implant and necessitating revision surgery. Wear-induced particulate debris is the main cause initiating this destructive process. The purpose of this article is to review recent advances in understanding of how wear debris causes osteolysis, and emergent strategies for the avoidance and treatment of this disease. A strong activator of the peri-implant innate immune this debris-induced inflammatory cascade is dictated by macrophage secretion of TNF-α, IL-1, IL-6, and IL-8, and PGE2, leading to peri-implant bone resorption through activation of osteoclasts and inhibition of osteoblasts through several mechanisms, including the RANK/RANKL/OPG pathway. Therapeutic agents against proinflammatory mediators, such as those targeting tumor necrosis factor (TNF), osteoclasts, and sclerostin, have shown promise in reducing peri-implant osteolysis in vitro and in vivo; however, radiographic changes and clinical diagnosis often lag considerably behind the initiation of osteolysis, making timely treatment difficult. Considerable efforts are underway to develop such diagnostic tools, therapies, and identify novel targets for therapeutic intervention.
While spinal disc pathology has traditionally been treated using fusion-based procedures, recent interest in motion-preserving disc arthroplasties has grown. Traditional spinal fusion is associated with loss of motion, alteration of native spine kinematics, and increased risks of adjacent segment disease. The motion conferred by disc arthroplasty is believed to combat these complications. While the first implant designs resulted in poor patient outcomes, recent advances in implant design and technology have shown promising radiographic and clinical outcomes when compared with traditional fusion. These results have led to a rapid increase in the utilization of disc arthroplasty, with rates of cervical arthroplasty nearly tripling over the course of 7 years. The purpose of this review was to discuss the evolution of implant design, the current implant designs utilized, and their associated outcomes. Although disc arthroplasty shows significant promise in addressing some of the drawbacks associated with fusion, it is not without its own risks. Osteolysis, implant migration, and the development of heterotopic ossification have all been associated with disc arthroplasty. As interest in these procedures grows, so does the interest in developing improved implant designs aimed at decreasing these adverse outcomes. Though they are still relatively new, cervical and lumbar disc arthroplasty are likely to become foundational methodologies for the treatment of disc pathology.
2 February 2022 in Journal of Shoulder and Elbow Surgery
Complex rotator cuff tears provide a significant challenge for treating surgeons, given their high failure rate following repair and the associated morbidity. The purpose of this study is to evaluate the clinical outcomes of patients who underwent biologically enhanced demineralized bone matrix augmentation of rotator cuff repairs. Twenty patients with complex rotator cuff tears underwent arthroscopic rotator cuff repair by a single surgeon with demineralized bone matrix (DBM) augmentation that was biologically enhanced with platelet-rich plasma and concentrated bone marrow aspirate. Post-operative MRI was used to determine surgical success. Patient reported outcome measures and range of motion data were collected pre-operatively and at the final post-operative visit for each patient. Ten patients (50%) with DBM augmentation of their arthroscopic rotator cuff repair were deemed non-failures. The failure group had less improvement of visual analogue pain scale (p = 0.017), Simple Shoulder Test (p = 0.032), Single Assessment Numerical Evaluation (p = 0.006) and abduction (p = 0.046). There was no difference between the groups for change in American Shoulder and Elbow Society score (p = 0.096), Constant-Murley score (p = 0.086), forward elevation (p = 0.191) or external rotation (p = 0.333). The present study found that 50% of patients who underwent biologically enhanced DBM augmentation of their rotator cuff repair demonstrated MRI-determined failure of supraspinatus healing.
19 August 2022 in Archives of orthopaedic and trauma surgery