Krishna Kolan

Dr. Krishna Kolan

Department of Mechanical and Aerospace Engineering, San Diego, CA, USA

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2011 in Biofabrication
Verified
Journal Article
Closed access
Krishna KolanKrishna Kolan
Krishna Kolan
MLMing C Leu
Ming C Leu
GHGregory E Hilmas
Gregory E Hilmas
RBRoger F Brown
Roger F Brown
MVMariano Velez
Mariano Velez
Bioactive glasses are promising materials for bone scaffolds due to their ability to assist in tissue regeneration. When implanted in vivo, bioactive glasses can convert into hydroxyapatite, the main mineral constituent of human bone, and form a strong bond with the surrounding tissues, thus providing an advantage over polymer scaffold materials. Bone scaffold fabrication using additive manufacturing techniques can provide control over pore interconnectivity during fabrication of the scaffold, which helps in mimicking human trabecular bone. 13-93 glass, a third-generation bioactive material designed to accelerate the body's natural ability to heal itself, was used in the research described herein to fabricate bone scaffolds using the selective laser sintering (SLS) process. 13-93 glass mixed with stearic acid (as the polymer binder) by ball milling was used as the powder feedstock for the SLS machine. The fabricated green scaffolds underwent binder burnout to remove the stearic acid binder and were then sintered at temperatures between 675 °C and 695 °C. The sintered scaffolds had pore sizes ranging from 300 to 800 µm with 50% apparent porosity and an average compressive strength of 20.4 MPa, which is excellent for non-load bearing applications and among the highest reported for an interconnected porous scaffold fabricated with bioactive glasses using the SLS process. The MTT labeling experiment and measurements of MTT formazan formation are evidence that the rough surface of SLS scaffolds provides a cell-friendly surface capable of supporting robust cell growth.

6 January 2017 in International Journal of Bioprinting
Verified
Journal Article
Open access
PDF file
CMCaroline Murphy
Caroline Murphy
Krishna KolanKrishna Kolan
Krishna Kolan
WLWenbin Li
Wenbin Li
JSJulie Semon
Julie Semon
DDDelbert Day
Delbert Day
MLMing Leu
Ming Leu
A major limitation of using synthetic scaffolds in tissue engineering applications is insufficient angiogenesis in scaffold interior. Bioactive borate glasses have been shown to promote angiogenesis. There is a need to investigate the biofabrication of polymer composites by incorporating borate glass to increase the angiogenic capacity of the fabricated scaffolds. In this study, we investigated the bioprinting of human adipose stem cells (ASCs) with a polycaprolactone (PCL)/bioactive borate glass composite. Borate glass at the concentration of 10 to 50 weight %, was added to a mixture of PCL and organic solvent to make an extrudable paste. ASCs suspended in Matrigel were ejected as droplets using a second syringe. Scaffolds measuring 10 × 10 × 1 mm3 in overall dimensions with pore sizes ranging from 100 – 300 µm were fabricated. Degradation of the scaffolds in cell culture medium showed a controlled release of bioactive glass for up to two weeks. The viability of ASCs printed on the scaffold was investigated during the same time period. This 3D bioprinting method shows a high potential to create a bioactive, highly angiogenic three-dimensional environment required for complex and dynamic interactions that govern the cell’s behavior in vivo.

1 September 2012 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Krishna KolanKrishna Kolan
Krishna Kolan
MLMing C. Leu
Ming C. Leu
GHGregory E. Hilmas
Gregory E. Hilmas
MVMariano Velez
Mariano Velez

12 July 2019 in International Journal of Bioprinting
Verified
Journal Article
Open access
Krishna KolanKrishna Kolan
Krishna Kolan
JSJulie A. Semon
Julie A. Semon
BBBradley Bromet
Bradley Bromet
DDDelbert E. Day
Delbert E. Day
MLMing C. Leu
Ming C. Leu
Three-dimensional (3D) bioprinting technologies have shown great potential in the fabrication of 3D models for different human tissues. Stem cells are an attractive cell source in tissue engineering as they can be directed by material and environmental cues to differentiate into multiple cell types for tissue repair and regeneration. In this study, we investigate the viability of human adipose-derived mesenchymal stem cells (ASCs) in alginate-gelatin (Alg-Gel) hydrogel bioprinted with or without bioactive glass. Highly angiogenic borate bioactive glass (13-93B3) in 50 wt% is added to polycaprolactone (PCL) to fabricate scaffolds using a solvent-based extrusion 3D bioprinting technique. The fabricated scaffolds with 12 × 12 × 1 mm3 in overall dimensions are physically characterized, and the glass dissolution from PCL/glass composite over a period of 28 days is studied. Alg-Gel composite hydrogel is used as a bioink to suspend ASCs, and scaffolds are then bioprinted in different configurations: Bioink only, PCL+bioink, and PCL/glass+bioink, to investigate ASC viability. The results indicate the feasibility of the solvent-based bioprinting process to fabricate 3D cellularized scaffolds with more than 80% viability on day 0. The decrease in viability after 7 days due to glass concentration and static culture conditions is discussed. The feasibility of modifying Alg-Gel with 13-93B3 glass for bioprinting is also investigated, and the results are discussed.

30 April 2020 in International Journal of Bioprinting
Verified
Journal Article
Open access
PDF file
Krishna KolanKrishna Kolan
Krishna Kolan
YHYue-Wern Huang
Yue-Wern Huang
JSJulie A. Semon
Julie A. Semon
MLMing C. Leu
Ming C. Leu
The pore geometry of scaffold intended for the use in the bone repair or replacement is one of the most important parameters in bone tissue engineering. It affects not only the mechanical properties of the scaffold but also the amount of bone regeneration after implantation. Scaffolds with five different architectures (cubic, spherical, x, gyroid, and diamond) at different porosities were fabricated with bioactive borate glass using the selective laser sintering (SLS) process. The compressive strength of scaffolds with porosities ranging from 60% to 30% varied from 1.7 to 15.5 MPa. The scaffold’s compressive strength decreased significantly (up to 90%) after 1-week immersion in simulated body fluids. Degradation of scaffolds is dependent on porosity, in which the scaffold with the largest surface area has the largest reduction in strength. Scaffolds with traditional cubic architecture and biomimetic diamond architecture were implanted in 4.6 mm diameter fullthickness rat calvarial defects for 6 weeks to evaluate the bone regeneration with or without bone morphogenetic protein 2 (BMP-2). Histological analysis indicated no significant difference in bone formation in the defects treated with the two different architectures. However, the defects treated with the diamond architecture scaffolds had more fibrous tissue formation and thus have the potential for faster bone formation. Overall, the results indicated that borate glass scaffolds fabricated using the SLS process have the potential for bone repair and the addition of BMP-2 significantly improves bone regeneration.

1 June 2020 in Bioprinting
Verified
Journal Article
Closed access
Krishna KolanKrishna Kolan
Krishna Kolan
JSJulie Semon
Julie Semon
ABAugust T. Bindbeutel
August T. Bindbeutel
DDDelbert E. Day
Delbert E. Day
MLMing C. Leu
Ming C. Leu