Kyriakos Oikonomou

Prof. Dr. Kyriakos Oikonomou

Department of Vascular and Endovascular Surgery, Cardiovascular Surgery Clinic, University Hospital Frankfurt, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
KOKyriakos Oikonomou
Kyriakos Oikonomou
KPKarin Pfister
Karin Pfister
PKPiotr M. Kasprzak
Piotr M. Kasprzak
WSWilma Schierling
Wilma Schierling
TBThomas Betz
Thomas Betz
GSGeorgios Sachsamanis
Georgios Sachsamanis
Objectives: To present our experience with various therapeutic approaches for the treatment of secondary aortoenteric fistulas following open and endovascular aortic aneurysm repair. Methods and Materials: A retrospective data analysis of patients treated for secondary aortoenteric fistulas in a single vascular institution between January 2005 and December 2018 was performed. Analyzed parameters included patients’ demographics, clinical presentation, diagnostic work-up, perioperative data and repair durability during follow-up. Results: Twenty-three patients with aortoenteric fistulas were treated in the target period. The fistulous connection was located in 21 cases (91.3%) in the duodenum and in two cases (8.7%) in the small intestine. Average time between the initial procedure and detection of the aortoenteric fistula was 69.4 ± 72.5 months. The most common presenting symptom was gastrointestinal bleeding (n = 12, 52.2%), followed by symptoms suggestive of chronic infection (n = 11, 47.8%). Open surgical repair was performed in 19 patients (bridging in 3 patients), and endovascular repair was carried out in two cases and one patient underwent a hybrid operation. One patient underwent abscess drainage due to significant comorbidities. Mean follow-up was 35.1 ± 35.5 months. In-hospital mortality and overall mortality were 43.5% (10/23) and 65.2% (15/23), respectively. Patients presenting with bleeding had a significantly higher perioperative mortality rate in comparison to patients presenting with chronic infection (66.7% (8/12) and 18.2% (2/11), respectively, p = 0.019). Patients who underwent stent-graft implantation for control of acute life-threatening bleeding showed significantly better perioperative survival in comparison to patients that were acutely treated with an open procedure (66.6%, (4/6) and 0% (0/6), respectively, p = 0.014). Perioperative mortality was also higher for ASA IV patients (71.4%, 5/7), when compared to ASA III Patients (31.2%, 5/16), although this did not reach statistical significance (p = 0.074). Conclusion: Treatment of secondary aortoenteric fistulas is associated with a high perioperative mortality rate. Patients who survive the perioperative period following open surgical repair in the absence of hemorrhagic shock show acceptable midterm results during follow-up. Stent-graft implantation for bleeding control in patients presenting with life-threatening bleeding seems to be associated with lower perioperative mortality rates.

10 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KOKyriakos Oikonomou
Kyriakos Oikonomou
AKAkaki Kvataia
Akaki Kvataia
KPKarin Pfister
Karin Pfister
EZEvgenia Zygouridou
Evgenia Zygouridou
TBThomas Betz
Thomas Betz
GSGeorgios Sachsamanis
Georgios Sachsamanis
Background: The purpose of this study is to assess the efficacy of a suture-mediated closure device during percutaneous endovascular aortic repair. Methods: A single-center, retrospective analysis of patients undergoing endovascular repair for infrarenal, thoracic and thoracoabdominal aortic aneurysms and aortic dissections via percutaneous femoral access between April 2017 and June 2021 was performed. The primary endpoint of the study was the efficacy and technical success of the Perclose ProGlide closure device during percutaneous endovascular procedures. The secondary endpoints were intraoperative and postoperative inguinal and vascular complications during and after device use. Results: A total of 376 punctures were performed in 263 patients with the deployment of the ProGlide vascular closure system. Twenty-two cases involved percutaneous re-puncture as part of a staged procedure. The primary and secondary technical success rates were 93.1% (350/376) and 94.7% (356/376), respectively. In 20 patients (5.3%), intraoperative femoral exposure due to complications was required. Postoperative complications occurred in 13 cases (3.5%), 2 of which required surgical reintervention. There was no statistical significance between the type of endovascular procedure and primary technical success (p = 0.56). The introduction of larger-diameter sheaths was not associated with increased intraoperative and postoperative complication rates (p = 0.75 and p = 0.78, respectively). Percutaneous re-puncture of the vascular access site did not result in a lower overall technical success rate (20/22, 90.9% primary technical success rate, p = 0.67; 21/22, 95.5% secondary technical success rate, p = 0.86) or an increased number of perioperative complications (1/22, 4.5% intraoperative complications, p = 0.86; 2/22, 9.1% postoperative complications, p = 0.13). Conclusion: The application of the ProGlide closure system is a safe and efficient method to achieve hemostasis during percutaneous endovascular aortic repair. Complex aortic pathologies, which often require a staged approach with re-puncture, can also be successfully treated with this closure system.

8 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
WDWojciech Derwich
Wojciech Derwich
ABAlexandru Barb
Alexandru Barb
Thomas Josef VoglThomas Josef Vogl
Thomas Josef Vogl
KOKyriakos Oikonomou
Kyriakos Oikonomou
DGDaphne Gray
Daphne Gray
Endovascular aortic repair (EVAR) is the primary treatment for abdominal aortic aneurysms (AAAs). To optimise patient safety during the standard EVAR procedure, we aimed to investigate the influence of patient anatomy on intraoperative radiation exposure and surgical time. This retrospective study comprised 90 patients (mean age 73.4 ± 8.2 years; 92.2% male) with an infrarenal aortic aneurysm who underwent a standard EVAR procedure. The relationships between dose area product, operating time, and anatomical conditions were investigated in preoperative computed tomography angiography using open-source software. Logistic regression analysis indicated that only body mass index (BMI) had predictive value for radiation exposure. The accuracy of the model was 98.67%, with an area under the curve of 0.72. The duration of surgery was significantly correlated with an increased BMI (odds ratio (OR) = 1.183; p < 0.05), the tortuosity of AAAs (OR = 1.124; p < 0.05), and the left common iliac artery (OR = 1.028; p < 0.05). Thus, BMI impacts the prediction of intraoperative radiation exposure more significantly than the anatomical characteristics of the infrarenal aorta and iliac arteries, and the duration of surgery significantly correlates with both BMI and the tortuosity of the infrarenal aorta and iliac arteries.

30 November 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DGDaphne Gray
Daphne Gray
CSCarla Samaan
Carla Samaan
KOKyriakos Oikonomou
Kyriakos Oikonomou
TGTatjana Gruber-Rouh
Tatjana Gruber-Rouh
TSThomas Schmitz-Rixen
Thomas Schmitz-Rixen
WDWojciech Derwich
Wojciech Derwich
In the past two decades, endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA) has become the first line treatment for infrarenal AAA repair in many countries. While short-term results are good, concerns have been raised about long-term durability. Changes in aortoiliac anatomy, especially at the landing zones, could play a role in EVAR failure over time. The current study aimed to determine certain morphological changes in the distal iliac landing zone after EVAR implantation, as well aspossible risk factors associated with iliac sealing failure. In a retrospective analysis of a tertiary single-centre registry, including patients treated with EVAR between January 2008 and July 2018, clinical follow-up data were assessed, and computer tomography (CT) imaging was evaluated regarding morphological changes in the iliac anatomy during follow-up. For clinical analysis all patients with a minimum follow-up of one year were included; for morphological analysis of iliac anatomy all patients with available CT follow-up of a minimum of one year and a minimum of two CT scans were included. Overall, 127 out of 241 treated patients (92.1% male) were included in the clinical follow-up. Complete CT imaging of 99 iliac arteries in 55 patients was available for morphological analysis. Median postoperative follow-up (FU) for these patients was 33 months (IQR 31; min–max: 12–124). Incidence of type 1b endoleak was 3% but iliac limb detachment from the vessel wall was seen in 18.2% of the target vessels. There was a significant difference in oversizing in iliac limbs with detachment (median 13.9%, IQR 23.1) vs. without detachment (median 23.1%, IQR 19.1) (p = 0.034). Iliac arteries at the landing zone showed a significant diameter increase independent of an endoleak presence (overall cohort median diameter increase at one year 23.1 mm; at two years 0 mm; at three years 4.9 mm). Iliac arteries with detachment (median 14.4%; IQR 23.9) showed a significantly higher diameter increase at the landing zone after four years compared to arteries without detachment (median 5.3%; IQR 9) (p = 0.042). Oversizing correlated positively with an iliac diameter increase at the landing zone over time (3 m: p= 0.001; one year: p < 0.001; two years: p < 0.001; three years: p = 0.006). Older patients showed a significantly lower diameter increase at the distal landing zone over time than younger patients in the first two years after EVAR (p < 0.001/r = −0.606 after two years). In the current study, iliac limb oversizing was associated with increased dilatation of the distal landing zone during a three-year follow-up, while iliac limb detachment was observed less often. An older age was inversely associated to the iliac diameter increase. Future studies should clarify the association between stent graft oversizing, age, and changes in the iliac anatomy in order to identify parameters that affect EVAR durability.

30 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KOKyriakos Oikonomou
Kyriakos Oikonomou
CZCarla Isabell Zimmler
Carla Isabell Zimmler
Abdominal aortic surgery has witnessed significant paradigm shifts in recent years with the introduction of structured screening programs, as well as the evolution of endovascular aortic aneurysm repair (EVAR), which has allowed physicians to promptly identify and successfully treat an increasing number of patients, even including those previously considered unfit for open repair