Mechanical ventilation may promote overdistension-induced pulmonary lesions in patients with acute respiratory distress syndrome (ARDS). The static pressure-volume (P-V) curve of the respiratory system can be used to determine the lung volume and corresponding static airway pressure at which lung compliance begins to diminish (the upper inflection point, or UIP). This fall in compliance may indicate overdistension of lung units. We prospectively studied 42 patients receiving mechanical ventilation with an FIO2 of 0.5 or more for at least 24 h. According to the Lung Injury Score (LIS), 25 patients were classified as having ARDS (LIS > 2.5), while 17 patients constituted a non-ARDS control group. The P-V curve was obtained every 2 d. Mechanical ventilation initially used standard settings (volume-control mode, a positive end-expiratory pressure [PEEP] adjusted to the lower inflection point on the P-V curve, and a tidal volume [VT] of 10 ml/kg). The end-inspiratory plateau pressure (Pplat) was compared to the UIP, and VT was lowered when the Pplat was above the UIP. In the range of lung volume studied on the P-V curves (up to 1600 ml), a UIP could be shown in only one control patient (at 23 cm H2O). By contrast, a UIP was present on the P-V curve obtained from all patients with ARDS, corresponding to a mean airway pressure of 26 +/- 6 cm H2O, a lung volume of 850 +/- 200 ml above functional residual capacity and 610 +/- 235 ml above PEEP.(ABSTRACT TRUNCATED AT 250 WORDS)
Introduction: Percutaneous dilatational tracheostomy (PDT) is one of the most frequent procedures performed in the intensive care unit (ICU). PDT may add potential benefit to clinical management of critically ill patients. Despite this, no clinical guidelines are available. We sought to characterize current practice in this international survey. Methods: An international survey, endorsed and peer reviewed by European Society of Intensive Care Medicine (ESICM), was carried out from May to October 2013. The questionnaire was accessible from the ESICM website in the ‘survey of the month’ section. Results: 429 physicians from 59 countries responded to this survey. Single step dilatational tracheostomy was the most used PDT in ICU. Almost 75 % of PDT’s were performed by intensive care physicians. The main indication for PDT was prolonged mechanical ventilation. Tracheostomies were most frequently performed between 7–15 days after ICU admission. Volume control mechanical ventilation, and a combination of sedation, analgesia, neuromuscular blocking agents and fiberoptic bronchoscopy were used. Surgical tracheostomy was mainly performed in ICU by ENT specialists, and was generally chosen when for patients at increased risk for difficult PDT insertion. Bleeding controlled by compression and stoma infection/inflammation were the most common intra-procedural and late complications, respectively. Informed consent for PDT was obtained in only 60 % of cases. Conclusions: This first international picture of current practices in regard to tracheostomy insertion demonstrates considerable geographic variation in practice, suggesting a need for greater standardization of approaches to tracheostomy insertion.
1 May 1997 in American Journal of Respiratory and Critical Care Medicine
Pressure-volume (P-V) curves of the respiratory system allow determination of compliance and lower and upper inflection points (LIP and UIP, respectively). To minimize lung trauma in mechanical ventilation the tidal volume should be limited to the P-V range between LIP and UIP. An automated low flow inflation (ALFI) technique, using a computer-controlled Servo Ventilator 900C, was compared with a more conventional technique using a series of about 20 different inflated volumes (Pst-V curve). The pressure in the distal lung (Pdist) was calculated by subtraction of resistive pressure drop in connecting tubes and airways. Compliance (Cdist), Pdist(LIP), and Pdist(UIP) were derived from the Pdist-V curve and compared with Cst, Pst(LIP), and Pst(UIP) derived from the Pst-V curve. Nineteen sedated, paralyzed patients (10 with ARDS and 9 with ARF) were studied. We found: Cdist = 2.3 + 0.98 x Cst ml/cm H2O (r = 0.98); Pdist(LIP) = 0.013 + 1.09 x Pst(LIP) cm H2O (r = 0.96). In patients with ARDS: Pdist(UIP) = 4.71 + 0.84 x Pst(UIP) cm H2O (r = 0.94). In ARF, we found differences in UIP between the methods, but discrepancies occurred above tidal volumes and had little practical importance. They may reflect that Pdist comprises dynamic phenomena contributing to pressure in the distal lung at large volumes. Compliance, but not LIP and UIP, could be accurately determined without subtraction of resistive pressure from the pressure measured in the ventilator. We conclude that ALFI, which is fully automated and needing no ventilator disconnection, gives useful clinical information.