Yu Gan

Dr. Yu Gan


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
CLCheng Lu
Cheng Lu
GLGuodong Liu
Guodong Liu
BLBingguo Liu
Bingguo Liu
FCFengdong Chen
Fengdong Chen
YGYu Gan
Yu Gan
We establish a theoretical model of the Doppler effect in absolute distance measurements using frequency scanning interferometry (FSI) and propose a novel FSI absolute distance measurement system. This system incorporates a basic FSI system and a laser Doppler velocimeter (LDV). The LDV results are used to correct for the Doppler effect in the absolute distance measurement signal obtained by the basic FSI system. In the measurement of a target located at 16 m, a measurement resolution of 65.5 μm is obtained, which is close to the theoretical resolution, and a standard deviation of 3.15 μm is obtained. The theoretical measurement uncertainty is 8.6 μm + 0.16 μm/m Rm (k = 2) within a distance range of 1 m to 24 m neglecting the influence of air refractive index, which has been verified with experiments.

25 April 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
CLCheng Lu
Cheng Lu
YXYong Xiang
Yong Xiang
YGYu Gan
Yu Gan
BLBingguo Liu
Bingguo Liu
FCFengdong Chen
Fengdong Chen
GLGuodong Liu
Guodong Liu
We propose a frequency swept interferometry (FSI)-based absolute distance measurement method that can be used to measure a noncooperative target located at a distance of 10s of m. In this method, an external cavity laser serves as the frequency tuning laser, and a single frequency laser and two acoustic optical modulators (AOMs) are used to measure the optical path difference (OPD) variation during the frequency tuning, which can correct the Doppler effect. A phase-locked loop (PLL) is introduced to synchronize the nonlinearities between the OPD variation measurement signal and the absolute distance measurement signal, improving the signal-to-noise ratio (SNR) of the OPD variation measurement signal. The distance to a noncooperative target located at 15 m is experimentally measured using this method, and a precision of 3.43 μm is obtained.

30 November 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
CLCheng Lu
Cheng Lu
GLGuodong Liu
Guodong Liu
BLBingguo Liu
Bingguo Liu
FCFengdong Chen
Fengdong Chen
THTao Hu
Tao Hu
YGYu Gan
Yu Gan
We establish a theoretical model of dispersion mismatch in absolute distance measurements using swept-wavelength interferometry (SWI) and propose a novel dispersion mismatch compensation method called chirp decomposition. This method separates the dispersion coefficient and distance under test, which ensures dispersion mismatch compensation without introducing additional random errors. In the measurement of a target located at 3.9 m, a measurement resolution of 45.9 μm is obtained, which is close to the theoretical resolution, and a standard deviation of 0.74 μm is obtained, which is better than the traditional method. The measurement results are compared to a single-frequency laser interferometer. The target moves from 1 m to 3.7 m, and the measurement precision using the new method is less than 0.81 μm .

5 December 2016 in Applied Optics
Verified
Journal Article
Closed access
PDF file
GLGuodong Liu
Guodong Liu
CLCheng Lu
Cheng Lu
BLBingguo Liu
Bingguo Liu
FCFengdong Chen
Fengdong Chen
YGYu Gan
Yu Gan
A high-precision and speed absolute distance measurement based on swept-wavelength interferometry is reported. A powerful method combining sub-Nyquist sampling and chirp decomposition for dispersion mismatch compensation is proposed. A standard deviation of 0.72 μm is obtained for the measurement of a target located at 3.9 m, which is better than the traditional method. The measurement can be completed in 1.9 s when the frequency range is 4.26 THz, which is much better than chirp decomposition without sub-Nyquist sampling.

1 January 2015 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
XXXu Xin-Ke
Xu Xin-Ke
LGLiu Guo-Dong
Liu Guo-Dong
LBLiu Bing-Guo
Liu Bing-Guo
CFChen Feng-Dong
Chen Feng-Dong
ZZZhuang Zhi-Tao
Zhuang Zhi-Tao
YGYu Gan
Yu Gan
The laser frequency scanning interferometer has several advantages, such as non-contact, high accuracy and low signal to noise ratio in detection. In order to achieve higher resolution of the laser frequency scanning interferometer, increasing the tuning range of the light source and reducing the tuning non-linearity have become the key factors. The commonly used method is to correct the non-linearity of the wide bandwidth external cavity tuning laser by a fiber optical auxiliary interferometer constructed external frequency sampling clock. When using the broadband external cavity tuning laser and the auxiliary interferometer with an optical path difference of 220 m, it is found experimentally that the single-mode fiber dispersion makes the frequency of sampled signals change over time, causing the spectrum to broaden and resolution to decline. This paper has established the dispersion mismatch model which shows that the fiber dispersion of the auxiliary interferometer causes linear chirp frequency changes during the measurement of signals. The linear chirp frequency is proportional to the tuning bandwidth and measured distance. The phenomenon and theoretical model of dispersion mismatch is verified by experiments. The results for targets in the air are shown to linearly decrease as the tuning range increases with the maximum offset of 156.3 µm for the 20 nm tuning bandwidth. The experiment also proves the peak broadening intensifies with increasing distance measured, and thus verifies as the time delay of free space increase, and the peak broadening and distortion also increases. This result means that it will limit the ranging distance and make large errors in measurement result for long distance targets. The dispersion of the auxiliary interferometer should be compensated in the laser frequency scanning interferometer for large-sized high resolution measurements. In this paper, phase dispersion compensation method based on the evolution of peak variation distortion elimination is proposed, by taking the peak amplitude variation as the criterion; the phase compensation can offset the dispersion and improve the resolution. The original signal is multiplied by the complex phase compensation term, then regulating the phase compensation factor, the chirp becomes smaller as the phase compensation factor is approaching the distortion factor. Under the condition that the phase compensation factor is equal to the distortion factor, the chirp is offset. Then, the relationship between the amplitude and the peak FWHM is studied. It is found that the peak FWHM decreases while the amplitude shows a gradually increasing trend. Therefore, the amplitude can be referred to in order to determine whether the peak FWHM reaches the minimum. The resolution for target's peak can be improved by searching for the maximum amplitude of the spectrum and adjusting the phase distortion coefficient. The experiment shows that the peak FWHM of the target is obviously narrowed after dispersion compensation. The peak value becomes close to the theoretical resolution, and the static target at a distance of 975.216254 mm from the laser frequency scanning interferometer is measured. Results show the measurement accuracy of the interferometer is 584 nm. To further verify the accuracy of the laser frequency scanning interferometer, the laser frequency scanning interferometer is compared with the Renishaw laser interferometer in the measurement range of 0692 mm. The standard deviation between them is 4.5 µm. The proposed method is put forward to provide basis for future studies on the large size high resolution laser frequency scanning interferometer.

1 January 2016 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
LGLiu Guo-Dong
Liu Guo-Dong
XXXu Xin-Ke
Xu Xin-Ke
LBLiu Bing-Guo
Liu Bing-Guo
CFChen Feng-Dong
Chen Feng-Dong
HTHu Tao
Hu Tao
YGYu Gan
Yu Gan
In the paper we study the method of reducing environmental influence in broadband laser frequency scanning interferometer. Target displacement caused by vibration will result in Doppler shift in measurement beat frequency. The extent of frequency shift is usually much larger than the actual target displacement. So the direct calculating of the target distance will cause ranging precision to decrease. In this paper, we establish a model for the influence of environmental vibration on the measurement and analyze the influence of the vibration on ranging result. To suppress the vibration effect, the Kalman filter is combined with the overlapping Chirp Z transform to estimate the measured data. The general process is described as follows. Firstly, the tuning nonlinearity will lead to the frequency spectrum broadening, so this paper we use the frequency sampling method to correct the frequency modulation nonlinearity of the laser. The frequency sampling method has the advantages of high speed and high precision. Secondly, the measurement system has the dispersion mismatch effect due to the use of broadband frequency swept laser. To solve this problem, the influence of the dispersion on the measurement is reduced by using the method of dispersion chirp slope calibration. Thirdly, because of the long frequency sweep period of the external cavity swept frequency laser, the vibration process of the target cannot be recorded in real time by single sweep, so in this paper we propose segmenting the measurement signal of single sweep and conducting Chirp Z transform to calculate target distance at different times. Compared with FFT algorithm, Chirp Z transform can achieve arbitrary narrow band spectrum subdivision, with the advantages of high accuracy and fast frequency measurement. Lastly, the Chirp Z ranging result is further combined with the method of Kalman filter to estimate the state of the target distance information. The experimental results indicate that the measurement standard is reduced from 185.4 μm to 9 μm by the proposed method. Without changing the absolute distance measuring device of broadband laser frequency scanning interferometer, this method provides a solution for further improving the ranging accuracy in the vibration environment, and reduces the complexity and cost of the device.