María Moreno-Guzmán

Prof. Dr. María Moreno-Guzmán

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
ÁMÁgueda Molinero-Fernández
Águeda Molinero-Fernández
MMMaría Moreno-Guzmán
María Moreno-Guzmán
MLMiguel Ángel López
Miguel Ángel López
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
Procalcitonin (PCT) is a known protein biomarker clinically used for the early stages of sepsis diagnosis and therapy guidance. For its reliable determination, sandwich format magnetic bead-based immunoassays with two different electrochemical detection approaches are described: (i) disposable screen-printed carbon electrodes (SPE-C, on-drop detection); (ii) electro-kinetically driven microfluidic chips with integrated Au electrodes (EMC-Au, on-chip detection). Both approaches exhibited enough sensitivity (limit of detection (LOD) of 0.1 and 0.04 ng mL−1 for SPE-C and EMC-Au, respectively; cutoff 0.5 ng mL−1), an adequate working range for the clinically relevant concentrations (0.5–1000 and 0.1–20 ng mL−1 for SPE-C and EMC-Au, respectively), and good precision (RSD < 9%), using low sample volumes (25 µL) with total assay times less than 20 min. The suitability of both approaches was successfully demonstrated by the analysis of human serum and plasma samples, for which good recoveries were obtained (89–120%). Furthermore, the EMC-Au approach enabled the easy automation of the process, constituting a reliable alternative diagnostic tool for on-site/bed-site clinical analysis.

17 August 2020 in Journal of Chemical Education
Verified
Journal Article
Closed access
ERElena Rodríguez-Rodríguez
Elena Rodríguez-Rodríguez
MSMarta Sánchez-Paniagua
Marta Sánchez-Paniagua
JSJon Sanz-Landaluze
Jon Sanz-Landaluze
MMMaría Moreno-Guzmán
María Moreno-Guzmán

29 March 2024 in Analytical Chemistry
Verified
Journal Article
Open access
ÁGÁlvaro Gallo-Orive
Álvaro Gallo-Orive
MMMaría Moreno-Guzmán
María Moreno-Guzmán
MSMarta Sanchez-Paniagua
Marta Sanchez-Paniagua
AMAna Montero-Calle
Ana Montero-Calle
RBRodrigo Barderas
Rodrigo Barderas
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
Micromotor (MM) technology offers a valuable and smart on-the-move biosensing microscale approach in clinical settings where sample availability is scarce in the case of Alzheimer's disease (AD). Soluble amyloid-β protein oligomers (AβO) (mainly AβO42) that circulate in biological fluids have been recognized as a molecular biomarker and therapeutic target of AD due to their high toxicity, and they are correlated much more strongly with AD compared to the insoluble Aβ monomers. A graphene oxide (GO)-gold nanoparticles (AuNPs)/nickel (Ni)/platinum nanoparticles (PtNPs) micromotors (MMGO-AuNPs)-based electrochemical label-free aptassay is proposed for sensitive, accurate, and rapid determination of AβO42 in complex clinical samples such as brain tissue, cerebrospinal fluid (CSF), and plasma from AD patients. An approach that implies the in situ formation of AuNPs on the GO external layer of tubular MM in only one step during MM electrosynthesis was performed (MMGO-AuNPs). The AβO42 specific thiolated-aptamer (AptAβO42) was immobilized in the MMGO-AuNPs via Au-S interaction, allowing for the selective recognition of the AβO42 (MMGO-AuNPs-AptAβO42-AβO42). AuNPs were smartly used not only to covalently bind a specific thiolated-aptamer for the design of a label-free electrochemical aptassay but also to improve the final MM propulsion performance due to their catalytic activity (approximately 2.0× speed). This on-the-move bioplatform provided a fast (5 min), selective, precise (RSD < 8%), and accurate quantification of AβO42 (recoveries 94-102%) with excellent sensitivity (LOD = 0.10 pg mL-1) and wide linear range (0.5-500 pg mL-1) in ultralow volumes of the clinical sample of AD patients (5 μL), without any dilution. Remarkably, our MM-based bioplatform demonstrated the competitiveness for the determination of AβO42 in the target samples against the dot blot analysis, which requires more than 14 h to provide qualitative results only. It is also important to highlight its applicability to the potential analysis of liquid biopsies as plasma and CSF samples, improving the reliability of the diagnosis given the heterogeneity and temporal complexity of neurodegenerative diseases. The excellent results obtained demonstrate the analytical potency of our approach as a future tool for clinical/POCT (Point-of-care testing) routine scenarios.

5 October 2022 in ACS Sensors
Verified
Journal Article
Open access
JGJosé Gordón
José Gordón
LALuis Arruza
Luis Arruza
MIMaría Dolores Ibáñez
María Dolores Ibáñez
MMMaría Moreno-Guzmán
María Moreno-Guzmán
MLMiguel Ángel López
Miguel Ángel López
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
A graphene oxide/nickel/platinum nanoparticle micromotor (MM)-based fluorescent aptassay is proposed to determine interleukin-6 (IL-6) in serum samples from low-birth-weight infants (gestational age of less than 32 weeks and birthweight below 1000 g) with sepsis suspicion. In this kind of patients, IL-6 has demonstrated good sensitivity and specificity for the diagnosis of sepsis, both for early and late onset sepsis. The approach was based on the adsorption of the aptamer for IL-6 tagged with 6-FAM as a fluorescent label (AptIL-6, λem = 520 nm) on the graphene oxide external layer (MMGO-AptIL-6) inducing fluorescence quenching (OFF state) and a subsequent on-the-move affinity recognition of IL-6 from AptIL-6 (IL-6-AptIL-6 complex) recovering the fluorescence (ON state). An aptamer against IL-6 was selected and developed by the systematic evolution of ligands by exponential enrichment technology. This approach displayed a suitable linear range of 0.07-1000 pg mL-1 (r = 0.995) covering the cut-off and clinical practice levels, allowing direct determination without any dilution and simplifying the analysis as well as exhibiting an excellent sensitivity (LOD = 0.02 pg mL-1) in ultralow volumes of diagnostic clinical samples (2 μL). A high agreement between IL-6 levels obtained from our MM-based approach and the method used by the Hospital was obtained (relative error < 3%). The MM-based aptassay is competitive in comparison with that of the Hospital, in terms of a significant reduction of the sample volume (15 times less) and enhanced sensitivity, employing similar analysis times. These results position MM technology with enough potential to achieve high sensitivities in low sample volumes, opening new avenues in diagnosis based on low sample volumes.

1 October 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
LGLaura García-Carmona
Laura García-Carmona
MMMaría Moreno-Guzmán
María Moreno-Guzmán
AMAida Martín
Aida Martín
SBSelma Benito-Martínez
Selma Benito-Martínez
AFAna B. Fernández-Martínez
Ana B. Fernández-Martínez
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
The role and reliable quantification of intracellular hydrogen peroxide during cancer therapy constitutes an unexplored and fascinating application. In this work, we report the fabrication of vertically aligned copper nanowires (v-CuNWs) using electrosynthesis on templates, and their application as a cut-and-paste exclusive and flexible electrochemical transducer. This easily adaptable electrodic platform is demonstrated for a fast, simple and free-enzyme selective quantification of intracellular hydrogen peroxide in Cisplatin-treated human renal HK-2 cells. The v-CuNWs sensor was compared with an HRP-enzyme-based biosensor showing excellent correlation and indicates the good selectivity and analytical performance of the v-CuNWs. This sensing approach opens novel avenues for monitoring cell death processes and shows the potential of H2O2 as a cellular damage biomarker, with a clear potency for further developments for in vitro diagnosis and its implication in cancer therapy.

17 February 1999 in Parasitology Research
Verified
Journal Article
Closed access
PDF file
RRR. M. Ros-Moreno
R. M. Ros-Moreno
MMMaría Moreno-Guzmán
María Moreno-Guzmán
AJA. Jiménez-González
A. Jiménez-González
FRF. Rodríguez-Caabeiro
F. Rodríguez-Caabeiro