This paper proposes an inertia emulation method that uses the frequency of the center of inertia (COI) as the feedback signal, aiming to slow the frequency change rate and raise the frequen-cy nadir during frequency-dropping events. An approximated model depicting the COI frequency dynamics is first introduced, which shows the COI frequency signal has low observabilities of electromechanical modes. Thus, this feature enables the pro-posed inertia emulation to react quickly to steep frequency changes without suffering any adverse impacts caused by elec-tromechanical dynamics, such as excessively saturating the con-trolled objects. Moreover, the electromechanical dynamics asso-ciated with small-signal stability properties will not be inter-rupted by the proposed inertia emulation. In addition, a simple yet effective computing procedure is proposed to configure the critical parameters, as the inertia emulation is implemented with multiple flywheel-based energy storage systems. Simulation re-sults obtained based on two large interconnected systems verify the effectiveness of the proposed inertia emulation in terms of improving the frequency transients as well as its limited correla-tion with the electromechanical dynamics of the system. The signal transmission latency's impacts on the proposed inertia emulation are also investigated and discussed.
Complex energy systems can effectively integrate renewable energy sources such as wind and solar power into the information network and coordinate the operation of renewable energy sources to ensure its reliability. In the voltage source converter‐based high voltage direct current system, the traditional vector control strategy faces some challenges, such as difficulty in PI parameters tuning and multiobjective optimizations. To overcome these issues, a finite control set model predictive control‐based advanced control strategy is proposed. Based on the discrete mathematical model of the grid‐side voltage source converter, the proposed strategy optimizes a value function with errors of current magnitudes to predict switching status of the grid‐side converter. Moreover, the abilities of the system in resisting disturbances and fault recovery are enhanced by compensating delay and introducing weight coefficients. The complex energy system in which the wind power is delivered by the voltage source converter‐based high voltage direct current system is modeled by Simulink and simulation results show that the proposed strategy is superior to the tradition PI control strategy under various situations, such as wind power fluctuation and fault occurrences.
This paper presents a novel method to enhance the low-voltage ride-through (LVRT) capability of a doubly fed induction generator (DFIG) equipped with an energy storage system (ESS) to provide voltage support during grid faults. Specifically, the transient DC-link voltage is regulated by controlling the ESS, which is connected to the DC-link capacitor of the DFIG. This is actually equivalent to absorbing the power imbalance between the captured wind power and the power delivered to the grid by the DFIG during the fault so that the DC-link voltage and the rotor current dynamics can be greatly improved. Moreover, both the rotor speed and the pitch angle are also controlled to initially react to the low-voltage transient, which includes increasing rotor speed to store the unbalanced energy as kinetic energy and augmenting the pitch angle to reduce the captured wind power. Thus, because of less unbalanced power flowing into the rotor, the DFIG dynamics can be further improved and the required ESS capacity can be saved. As the grid-side converter (GSC) is not necessarily required to manage the transient DC-link voltage, it is manipulated to devote its entire capacity to injecting reactive power into the grid for voltage support during a fault. Comparisons with the conventional control strategy are obtained by simulating a single machine-infinite bus power system. It is verified that the proposed method can not only ensure the LVRT capability of DFIG by saving the ESS capacity, but also significantly improve the terminal voltage dynamics during the grid fault.
In order to improve the prediction accuracy of short-term wind power, a PCA-GA-LSTM short-term wind power combination prediction algorithm based on NWP is proposed. First, principal component analysis is used to reduce the dimension and denoise NWP sample data, and then genetic algorithm is used to train and optimize the model parameters of short-term memory artificial neural network (LSTM), such as learning rate, number of hidden layer nodes, regularization coefficient, etc. Finally, NWP historical data after dimension reduction is used as learning samples to train the neural network, and real-time information is processed to obtain prediction results. The results show that the prediction accuracy based on PCA-GA-LSTM neural network model is good, which has certain reference value for short-term wind power prediction.
The double‐fed induction wind generator‐ (DFIG‐) based wind generation system contains power electronic converters and filter capacitor and inductor, which will bring about high‐frequency harmonics under the influence of controllers. Aiming at this problem, this paper studies the relation between the output current and the harmonic source at grid‐side and rotor‐side converters based on their control features in the DFIG system. Furthermore, the harmonic equivalent models of these two converters are built, and the influence of different factors on harmonic features is explored from four perspectives, i.e., modulation method, altering controller parameters, altering output power, and the unbalance of three‐phase voltage. Finally, the effectiveness of the proposed model is verified through the 2 MW DFIG real‐time hardware‐in‐the‐loop test platform by StarSim software and real test data, respectively.
A novel control method for a doubly-fed induction generator (DFIG) equipped with an energy storage Device (ESD) to enhance its transient voltage support capacity during grid faults. Specifically, the ESD connected to the DC-link capacitor of the DFIG is controlled to regulate the transient DC-link voltage. This is actually equivalent to absorb the power imbalance between the captured wind power and the power delivered to the grid by the DFIG during the fault so that the DC-link voltage and the rotor current dynamics can be greatly improved. Moreover, the rotor speed and the pitch angle are also controlled to initiatively react to the low voltage transient, which includes increasing the rotor speed to store the unbalanced energy as kinetic energy and augmenting the pitch angle to decrease the captured wind power. Thus, due to less unbalanced power flowing into the rotor, the DFIG dynamics can be further ameliorated and the required ESD capacity can be obviously saved. As the grid side converter (GSC) can be free from managing the transient DC-link voltage, it is manipulated to devote its whole capacity to inject reactive power to the grid for voltage support during the fault. By simulating a single-machine-infinite-bus power system, comparisons with other control methods are conducted to prove that the novel proposed control method can well ensure the DFIG LVRT capability but save the ESD capacity, and also significantly improve the terminal voltage dynamics during the grid fault.