JING JING ZHAO

Dr. JING JING ZHAO


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2021 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
YHYong Han
Yong Han
ZJZeheng Jiao
Zeheng Jiao
JZJING JING ZHAO
JING JING ZHAO
ZCZixi Chao
Zixi Chao
Zheng YouZheng You
Zheng You

30 January 2024 in Infrared Physics & Technology
Verified
Journal Article
Closed access
JZJING JING ZHAO
JING JING ZHAO
XFXinye Fan
Xinye Fan
FFFang wenjing Fang
Fang wenjing Fang
WXWenxing Xiao
Wenxing Xiao
FSFangxin Sun
Fangxin Sun
Santosh KumarSantosh Kumar
Santosh Kumar

28 November 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
XGXiangyu Guo
Xiangyu Guo
XLXiaochen Li
Xiaochen Li
XWXinyue Wang
Xinyue Wang
MLMingxin Li
Mingxin Li
XDXiaochuan Dai
Xiaochuan Dai
LSLiqun Sun
Liqun Sun
Optical coherence tomography (OCT) is an emerging optical imaging technology that holds great potential in medical and biological applications. Apart from its conventional ophthalmic uses, it has found extensive applications in studying various brain activities and disorders in anesthetized/restricted rodents, with a particular focus on visualizing brain blood vessel morphology and function. However, developing a compact wearable OCT probe for studying the brain activity/disorders in freely moving rodents is challenging due to the requirements for stability and lightweight design. Here, we report a robust wearable OCT probe, which, to the best of our knowledge, is the first wearable OCT angiography probe capable of long-term monitoring of mouse brain blood flow. This wearable imaging probe has a maximum scanning speed of 76 kHz, with a 12 µm axial resolution, 5.5 µm lateral resolution, and a large field of view (FOV) of 4 mm × 4 mm. It offers easy assembly and stable imaging, enabling it to capture brain vessels in freely moving rodents. We tested this probe to monitor cerebral hemodynamics for up to 4 hours during the acute ischemic phase after photothrombotic stroke in mice, highlighting the reliability and long-term stability of our probe. This work contributes to the advancement of wearable biomedical imaging.

30 January 2021 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
ZJZeheng Jiao
Zeheng Jiao
JZJING JING ZHAO
JING JING ZHAO
YHYong Han
Yong Han
ZCZixi Chao
Zixi Chao
Zheng YouZheng You
Zheng You

26 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
ZCZixi Chao
Zixi Chao
YHYong Han
Yong Han
ZJZeheng Jiao
Zeheng Jiao
Zheng YouZheng You
Zheng You
JZJING JING ZHAO
JING JING ZHAO
Flow cytometers are instruments used for the rapid quantitative analysis of cell suspension. Traditional flow cytometry uses multi-channel filters to detect fluorescence, whereas full-spectrum fluorescence based on dispersion detection is a more effective and accurate method. The application of various dispersion schemes in flow cytometry spectroscopy has been studied. From the perspective of modern detectors and demand for the miniaturization of flow cytometry, prism dispersion exhibits higher and more uniform light energy utilization, meaning that it is a more suitable dispersion method for small flow cytometers, such as microfluidic flow cytometers. Prism dispersion designs include the size, number, and placement of prisms. By deducing the formula of the final position of light passing through the prism and combining it with the formula of transmittance, the design criteria of the top angle and the incident angle of the prism in pursuit of the optimum transmittance and dispersion index can be obtained. Considering the case of multiple prisms, under the premise of pursuing a smaller size, the optimal design criteria for dispersion system composed of multiple prisms can be obtained. The design of prism dispersion fluorescence detection was demonstrated with a microfluidic flow cytometer, and the effectiveness of the design results was verified by microsphere experiments and practical biological experiments. This design criterion developed in this study is generally applicable to spectral flow cytometers.

18 May 2022 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
ZJZeheng Jiao
Zeheng Jiao
YHYong Han
Yong Han
JZJING JING ZHAO
JING JING ZHAO
ZCZixi Chao
Zixi Chao
ATAttila Tárnok
Attila Tárnok
Zheng YouZheng You
Zheng You
Precise and high-speed sorting of individual target cells from heterogeneous populations plays an imperative role in cell research. Although the conventional fluorescence-activated cell sorter (FACS) is capable of rapid and accurate cell sorting, it occupies a large volume of the instrument and inherently brings in aerosol generation as well as cross-contamination among samples. The sorting completed in a fully enclosed and disposable microfluidic chip has the potential to eliminate the above concerns. However, current microfluidic cell sorters are hindered by the high complexities of the fabrication procedure and the off-chip setup. In this paper, a spark-cavitation-bubble-based fluorescence-activated cell sorter is developed to perform fast and accurate sorting in a microfluidic chip. It features a simple structure and an easy operation. This microfluidic sorter comprises a positive electrode of platinum and a negative electrode of tungsten, which are placed on the side of the main channel. By applying a high-voltage discharge on the pair of electrodes, a single spark cavitation bubble is created to deflect the target particle into the downstream collection channel. The sorter has a short switching time of 150 μs and a long lifespan of more than 100 million workable actions. In addition, a novel control strategy is proposed to dynamically adjust the discharge time to stabilize the size of the cavitation bubble for continuous sorting. The dynamic control of continuously triggering the sorter, the optimal delay time between fluorescence detection and cell sorting, and a theoretical model to predict the ideal sorting recovery and purity are studied to improve and evaluate the sorter performance. The experiments demonstrate that the sorting rate of target particles achieves 1200 eps, the total analysis throughput is up to 10,000 eps, the particles sorted at 4000 eps exhibit a purity greater than 80% and a recovery rate greater than 90%, and the sorting effect on the viability of HeLa cells is negligible.