Donghyeon Shin

Donghyeon Shin


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2023 in Batteries
Verified
Journal Article
Open access
PDF file
NYNayoung You
Nayoung You
JHJeonggyun Ham
Jeonggyun Ham
DSDonghyeon Shin
Donghyeon Shin
HCHonghyun Cho
Honghyun Cho
In this study, the effects of battery thermal management (BTM), pumping power, and heat transfer rate were compared and analyzed under different operating conditions and cooling configurations for the liquid cooling plate of a lithium-ion battery. The results elucidated that when the flow rate in the cooling plate increased from 2 to 6 L/min, the average temperature of the battery module decreased from 53.8 to 50.7 °C, but the pumping power increased from 0.036 to 0.808 W. In addition, an increase in the width of the cooling channel and number of channels resulted in a decrease in the average temperature of the battery module and a reduction in the pumping power. The most influential variable for the temperature control of the battery was an increase in the flow rate. In addition, according to the results of the orthogonal analysis, an increase in the number of cooling plate channels resulted in the best cooling performance and reduced pumping power. Based on this, a cooling plate with six channels was applied to both the top and bottom parts, and the top and bottom cooling showed sufficient cooling performance in maintaining the average temperature of the battery module below 45 °C.

1 August 2019 in Transaction of the Korean Society of Automotive Engineers
Verified
Journal Article
Open access
HSHyunsik Song
Hyunsik Song
JCJaeyoung Choi
Jaeyoung Choi
DPDohyun Park
Dohyun Park
Namwook KimNamwook Kim
Namwook Kim
DSDonghyeon Shin
Donghyeon Shin

20 October 2022 in Batteries
Verified
Journal Article
Open access
PDF file
MKMinjun Kim
Minjun Kim
JHJeonggyun Ham
Jeonggyun Ham
DSDonghyeon Shin
Donghyeon Shin
HCHonghyun Cho
Honghyun Cho
This study compares the performance according to a working fluid, the number of battery cooling block ports, and header width required for cooling according to the application of the direct contact single-phase battery cooling method in a 1S16P battery module and examines the battery cooling performance according to the flow rate under the standard and summer conditions based on an optimized model. The analysis result verified that R134a showed low-pressure drop and high cooling performance as the working fluid of the direct contact single-phase cooling system in the 1S16P battery module, and R134a showed the best cooling and stability when applied with three ports and a 5 mm header. In addition, under 25 °C outdoor conditions, the maximum temperature of the battery and the temperature difference between the batteries at 3 and 5 lpm excluding 1 lpm are 30.5 °C, 4.91 °C, and 28.7 °C, 3.28 °C, indicating that the flow rate of refrigerant was appropriate for battery safety. In contrast, in the summer condition of 35 °C, the maximum temperature of the battery and temperature difference between the batteries were 38.8 °C and 3.27 °C at the R134a flow rate of 5 lpm or more, which was verified as a stable flow condition for battery safety.