Zhiwei Tian

Mr. Zhiwei Tian


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2021 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
YSYanYan Shi
YanYan Shi
YWYuehui Wu
Yuehui Wu
MWMeng Wang
Meng Wang
ZTZhiwei Tian
Zhiwei Tian
XKXiaolong Kong
Xiaolong Kong
XHXiaoyue He
Xiaoyue He
Purpose: Intracerebral hemorrhage (ICH) is a common disease that is known for its high morbidity, high mortality, and high disability. The fast and accurate detection of ICH is essential for the acute care of patients. Electrical impedance tomography (EIT) offers an alternative with which pathological tissues can be detected by reconstructing conductivity variation. Nevertheless, the sensitive field of EIT is greatly affected by medium distribution, which is referred to as soft-field effect. In addition, the image reconstruction is a severely ill-posed inverse problem. Furthermore, due to the low conductivity of skull, the sensitivity in the sensing area is extremely low. Therefore, the reconstruction of ICH with EIT is great challenge. Approach: A sparse image reconstruction method is proposed for EIT to visualize the conductivity variation caused by ICH. To reduce the impact of soft-field effect, the normalization of sensitivity distribution is conducted for monolayer and three-layer head model. In addition, a constrained sparse L1-norm minimization model is developed for the image reconstruction. Augmented Lagrangian multiplier method and alternating minimization scheme are adopted to solve the proposed model. Results: The results show that the sensitivity in the sensing area is largely enhanced. Numerical simulation based on monolayer head model and three-layer head model is respectively carried out. Both the reconstructed images and the quantitative evaluations show that image reconstructed by the proposed method is much better than that reconstructed by traditional Tikhonov method. The reconstructions evaluated under the impact of noise also show that the proposed method has superior anti-noise performance. Conclusions: With the proposed method, the quality of the reconstructed image would be greatly improved. It is an effective approach for imaging ICH with EIT technique.

1 January 2023 in Inverse Problems and Imaging
Verified
Journal Article
Closed access
PDF file
YSYanYan Shi
YanYan Shi
YLYajun Lou
Yajun Lou
MWMeng Wang
Meng Wang
SZShuo Zheng
Shuo Zheng
ZTZhiwei Tian
Zhiwei Tian
FFFeng Fu
Feng Fu
Electrical impedance tomography (EIT) is a promising technique in medical imaging. With this technique, pathology-related conductivity variation can be visualized. Nevertheless, reconstruction of conductivity distribution is a severely ill-posed inverse problem which poses a great challenge for the EIT technique. Especially in brain EIT, irregular and multi-layered head structure along with low-conductivity skull brings more difficulties for accurate reconstruction. To address such problems, a novel reconstruction method which combines Tikhonov regularization with denoising algorithm is proposed for imaging conductivity distribution in brain EIT. With the proposed method, image reconstruction of intracerebral hemorrhage in different brain lobes of a three-layer head model is conducted. Besides, simultaneous reconstruction of intracerebral hemorrhage and secondary ischemia is performed. Meanwhile, the impact of noise is investigated to evaluate the anti-noise performance. In addition, image reconstructions under head shape deformation are performed. The proposed reconstruction method is also quantitatively estimated by calculating blur radius and structural similarity. Phantom experiments are carried out to further verify the effectiveness of the proposed method. Both qualitative and quantitative results have demonstrated that the proposed combined method is superior to Tikhonov regularization in imaging conductivity distribution. This work would provide an alternative for accurate reconstruction in EIT based medical imaging.

6 July 2021 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
YSYanYan Shi
YanYan Shi
ZTZhiwei Tian
Zhiwei Tian
MWMeng Wang
Meng Wang
FFFeng Fu
Feng Fu
YWYuehui Wu
Yuehui Wu
<!-- *** Custom HTML *** --> Purpose: Caused by brain trauma or blood vessel abnormality, intracerebral hemorrhage and secondary ischemia have become prevalent and severe neurological diseases. The timely and accurate detection of disease is essential for the recovery of patients. As an emerging visualization technique, electrical impedance tomography (EIT) offers an alternative. It is able to reconstruct the conductivity distribution that reflects the pathological variation of human tissue. Approach: In the EIT-based detection, electrodes are usually in uniform arrangement, which may be not suitable in some conditions. To enhance sensitivity in the region of interest, EIT with a novel offset arrangement of boundary electrodes is proposed to image a simulated frontal lobe hemorrhage and secondary ischemia. To cope with the ill-posed inverse problem, the L1 regularization method is developed during the reconstruction. In addition, the impact of noise with a signal-to-noise ratio of 56 dB is studied. Results: Compared with the traditional uniform electrode arrangement, the results demonstrate that EIT with the proposed offset arrangement of electrodes is more advantageous for imaging frontal lobe disease. Conclusions: The proposed offset arrangement of electrodes is superior to the traditional uniform arrangement in imaging frontal lobe disease, especially under the impact of noise.