Jaekyeong Jang

Mr. Jaekyeong Jang

Seoul National University of Science and Technology, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
JSjinhyeuk song
jinhyeuk song
JJJaekyeong Jang
Jaekyeong Jang
TKTaehoon Kim
Taehoon Kim
Young Hak ChoYoung Hak Cho
Young Hak Cho
In this study, we investigated the particle separation phenomenon in a microchannel with a T-shaped cross-section, a unique design detailed in our previous study. Utilizing a co-flow system within this T-shaped microchannel, we examined two types of flow configuration: one where a Newtonian fluid served as the inner fluid and a viscoelastic fluid as the outer fluid (Newtonian/viscoelastic), and another where both the inner and outer fluids were Newtonian fluids (Newtonian/Newtonian). We introduced a mixture of three differently sized particles into the microchannel through the outer fluid and observed that the co-flow of Newtonian/viscoelastic fluids effectively separated particles based on their size compared with Newtonian/Newtonian fluids. In this context, we evaluated and compared the particle separation efficiency, recovery rate, and enrichment factor across both co-flow configurations. The Newtonian/viscoelastic co-flow system demonstrated a superior efficiency and recovery ratio when compared with the Newtonian/Newtonian system. Additionally, we assessed the influence of the flow rate ratio between the inner and outer fluids on particle separation within each co-flow system. Our results indicated that increasing the flow rate ratio enhanced the separation efficiency, particularly in the Newtonian/viscoelastic co-flow configuration. Consequently, this study substantiates the potential of utilizing a Newtonian/viscoelastic co-flow system in a T-shaped straight microchannel for the simultaneous separation of three differently sized particles.

19 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JJJaekyeong Jang
Jaekyeong Jang
UKUihwan Kim
Uihwan Kim
TKTaehoon Kim
Taehoon Kim
Young Hak ChoYoung Hak Cho
Young Hak Cho
Recently, particle manipulation in non-Newtonian fluids has attracted increasing attention because of a good particle focusing toward the mid-plane of a channel. In this research, we proposed a simple and robust fabrication method to make a microchannel with various T-shaped cross-sections for particle focusing and separation in a viscoelastic solution. SU-8-based soft lithography was used to form three different types of microchannels with T-shaped cross-sections, which enabled self-alignment and plasma bonding between two PDMS molds. The effects of the flow rate and geometric shape of the cross-sections on particle focusing were evaluated in straight microchannels with T-shaped cross-sections. Moreover, by taking images from the top and side part of the channels, it was possible to confirm the position of the particles three-dimensionally. The effects of the corner angle of the channel and the aspect ratio of the height to width of the T shape on the elasto-inertial focusing phenomenon were evaluated and compared with each other using numerical simulation. Simulation results for the particle focusing agreed well with the experimental results both in qualitatively and quantitatively. Furthermore, the numerical study showed a potential implication for particle separation depending on its size when the aspect ratio of the T-shaped microchannel and the flow rate were appropriately leveraged.

6 November 2024 in Biomicrofluidics
Verified
Journal Article
Closed access
JJJaekyeong Jang
Jaekyeong Jang
JAJiyeon Ahn
Jiyeon Ahn
TKTaehoon Kim
Taehoon Kim
Young Hak ChoYoung Hak Cho
Young Hak Cho
Considerable attention has been given to elasto-inertial microfluidics, which are widely applied for the focusing, sorting, and separation of particles/cells. In this work, we propose a novel yet simple fabrication process for a microchannel with a cruciform section, where elasto-inertial particle focusing is explored in a viscoelastic fluid. SU-8 master molds for polydimethylsiloxane (PDMS) structures were fabricated via standard photolithography, and then plasma bonding, following self-alignment between two PDMS structures, was performed for the formation of a microchannel with a cruciform section. The particle behaviors inside the fabricated microchannel were experimentally investigated for various flow rates and particle sizes and compared with those inside a microchannel with a square cross section. The experimental results revealed that 3D particle focusing was achieved in the center under viscoelastic fluid flow over a wide range of flow rates without any shear thinning. Even for small particles (∼2 μm), single-line particle focusing was observed in the microchannel with a cruciform section but not in a square microchannel with the same hydraulic diameter (Dh = 75 μm). The effects of four reflex angles (270°) on particle focusing were quantitatively evaluated through numerical simulation. The simulation revealed that the migration pattern of particles is governed by the combined effect of the reflex angles and fluid inertia, leading to characteristic particle focusing behavior within the cross section of the cruciform microchannel. These findings agree well with the experimental results, which highlight the superior capability of the cruciform microchannel for inertial particle focusing across a wide range of particle sizes.

9 June 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
JJJaekyeong Jang
Jaekyeong Jang
EKEunjin Kim
Eunjin Kim
SKSungdong Kim
Sungdong Kim
OJOk Chan Jeong
Ok Chan Jeong
SLSang Wook Lee
Sang Wook Lee
Young Hak ChoYoung Hak Cho
Young Hak Cho
The manipulation of cells and bioparticles has garnered significant interest in the field of viscoelastic microfluidics, particularly regarding its capacity for single-stream focusing within a three-dimensional and simple microchannel structure. The inherent simplicity of this method enables the effective manipulation of particles, facilitating the separation and focusing of various cell types, including blood cells, circulating tumor cells (CTCs), and microalgae. However, the viscoelastic nature of the particles imposes limitations in the handling of submicron-sized particles, due to a significant decrease in the viscoelastic force acting on the particle. In this study, we propose a microfluidic device featuring a cruciform cross-sectional microchannel with 45 µm and 45 µm of its vertical and horizontal size, respectively. The cruciform microchannel, which has a 270° reflex angle on four corners, can increase the viscoelastic force on the particles, allowing the device to focus submicron-sized particles down to 180 nm in a single-stream manner. It is important to note that the single-stream formation was maintained, while the channel width at the outlet region was drastically increased, allowing for the enrichment of submicron-sized particles. For biological feasibility, the proposed device also demonstrates the single-stream focusing on biological particles such as bacteria. The presented microfluidic device would have great potential for the focusing and enrichment of nanoparticles including bacteria in a highly robust manner, expecting its use in the various fields such as diverse biological analysis and biomedical research.