Costas Kokolakis

Dr. Costas Kokolakis


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
CKCostas Kokolakis
Costas Kokolakis
DPDimitrios Piretzidis
Dimitrios Piretzidis
Stelios MertikasStelios Mertikas
Stelios Mertikas
Satellite altimetry plays a key role in monitoring changes in sea level and climate change. The quality of satellite altimetry products is commonly ensured through dedicated calibration. One such calibration is with microwave transponders acting as ground reference point targets. It is common practice that satellite ranges between the transponder phase center and the satellite center of gravity (CoG) are compared against the true geometric ranges to determine bias. Transponder ranges are, however, realized by the two phase centers of the altimeter and the ground transponder. So, to make this comparison feasible, the space origin of the measured range is transferred from the altimeter phase center (APC) to the satellite CoG by applying a constant offset, usually referred to as “CoG correction”. Instead of a fixed “CoG correction”, this work introduces the actual vector between APC and CoG in space, by examining the satellite attitude. Thus, the observed and geometric distances to the transponder are both referred to the APC. The case of Jason-3 and Sentinel-6A Michael Freilich (Sentinel-6A MF) with two transponders on Crete (CDN1) and Gavdos (GVD1) islands is examined. At first, the attitude of Jason-3 is determined by its quaternions. Then, analysis reveals that the transponder bias is correlated with the Jason-3 satellite attitude. The revised calibration brings about bias changes which fluctuate from about −2 mm to 1 mm in range and from −110μs to +110 μs in datation for Jason-3. Spectral analysis on the bias differences between the revised and conventional transponder calibrations reveals constituents with periods of 117, 39 and 23 days. Finally, the revised methodology on crossover calibrations over the GVD1 transponder results in an improvement between the mean bias of the ascending and descending orbits by 12% for Jason-3 and by 14% (preliminary) for Sentinel-6A MF.

1 March 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Stelios MertikasStelios Mertikas
Stelios Mertikas
MLMingsen Lin
Mingsen Lin
DPDimitrios Piretzidis
Dimitrios Piretzidis
CKCostas Kokolakis
Costas Kokolakis
CDCraig Donlon
Craig Donlon
LYLei Yang
Lei Yang
This research and collaboration work aims at the calibration and validation (Cal/Val) of the Chinese HY-2B satellite altimeter based upon two permanent Cal/Val facilities: (1) the China Altimetry Calibration Cooperation Plan in Qingdao, Bohai Sea and the Wanshan islands, China and (2) the permanent facility for altimetry calibration established by the European Space Agency in Crete, Greece. The HY-2B satellite altimeter and its radiometer have been calibrated and monitored using uniform, standardized procedures, as well as protocols and best practices, and they also built upon trusted and indisputable reference standards at both Cal/Val infrastructures in Europe and China. The HY-2B altimeter is thus monitored in a coordinated, absolute, homogeneous, long-term and worldwide manner. Calibration of altimeters is accomplished by examining satellite observations in open seas against reference measurements. Comparisons are established through precise satellite positioning, water level observations, GPS buoys and reference models (geoid, mean dynamic topography, earth tides, troposphere and ionosphere), all defined at the Cal/Val sites. In this work, the final uncertainty for the altimeter bias will be attributed to several individual sources of uncertainty, coming from observations in water level, atmosphere, absolute positioning, reference surface models, transfer of heights from Cal/Val sites to satellite observations, etc. Through this project, the procedures, protocols and best practices, originally developed in the course of the ESA FRM4ALT project, are updated, upgraded and followed at both Cal/Val facilities in Europe and China. All in all, the HY-2B satellite altimeter observes the sea level quite well and within its specifications.

5 January 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Stelios MertikasStelios Mertikas
Stelios Mertikas
CDCraig Donlon
Craig Donlon
CKCostas Kokolakis
Costas Kokolakis
DPDimitrios Piretzidis
Dimitrios Piretzidis
RCRobert Cullen
Robert Cullen
JSJérôme Saunier
Jérôme Saunier
Two microwave transponders have been operating in west Crete and Gavdos to calibrate international satellite radar altimeters at the Ku-band. One has been continuously operating for about 8 years at the CDN1 Cal/Val site in the mountains of Crete, and the other at the GVD1 Cal/Val site on Gavdos since 11 October 2021. This ground infrastructure is also supported at present by four sea-surface Cal/Val sites operating, some of them for over 20 years, while two additional such Cal/Val sites are under construction. This ground infrastructure is part of the European Space Agency Permanent Facility for Altimetry Calibration (PFAC), and as of 2015, it has been producing continuously a time series of range biases for Sentinel-3A, Sentinel-3B, Sentinel-6 MF, Jason-2, Jason-3, and CryoSat-2. This work presents a thorough examination of the transponder Cal/Val responses to understand and determine absolute biases for all satellite altimeters overflying this ground infrastructure. The latest calibration results for the Jason-3, Copernicus Sentinel-3A and -3B, Sentinel-6 MF, and CryoSat-2 radar altimeters are described based on four sea-surface and two transponder Cal/Val sites of the PFAC in west Crete, Greece. Absolute biases for Jason-3, Sentinel-6 MF, Sentinel-3A, Sentinel-3B, and CryoSat-2 are close to a few mm, determined using various techniques, infrastructure, and settings.

11 August 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Stelios MertikasStelios Mertikas
Stelios Mertikas
CDCraig Donlon
Craig Donlon
ATAchilles Tripolitsiotis
Achilles Tripolitsiotis
CKCostas Kokolakis
Costas Kokolakis
AMAntonio Martellucci
Antonio Martellucci
PFPierre Femenias
Pierre Femenias
In satellite altimetry calibration, the atmosphere’s integrated water vapor content has been customarily derived through the Global Navigation Satellite Systems (GNSS), principally over land where the satellite radiometer is not operational. Progressively, several alternative methods have emerged to estimate this wet troposphere component with ground instruments, alternative satellite sensors, and global models. For any ground calibration facility, integration of various approaches is required to arrive at an optimum value of a calibration constituent and in accordance with the strategy of Fiducial Reference Measurements (FRM). In this work, different estimation methods and instruments are evaluated for wet troposphere delays, especially when transponder and corner reflectors are employed at the Permanent Facility for Altimetry Calibration of the European Space Agency. Evaluation includes, first, ground instruments with microwave radiometers and radiosondes; second, satellite sensors with the Ocean Land Color Instrument (OLCI) and the Sea Land Surface Temperature Radiometer (SLSTR) of the Copernicus Sentinel-3 altimeter, as well as the TROPOMI spectrometer on the Sentinel-5P satellite; and finally with global atmospheric models, such as the European Center for Medium-Range Weather Forecasts. Along these lines, multi-sensor and redundant values for the troposphere delays are thus integrated and used for the calibration of Sentinel-6 MF and Sentinel-3A/B satellite altimeters. All in all, the integrated water vapor value of the troposphere is estimated with an FRM uncertainty of ±15 mm. In the absence of GNSS stations, it is recommended that the OLCI and SLSTR measurements be used for determining tropospheric delays in daylight and night operations, respectively. Ground microwave radiometers can also be used to retrieve tropospheric data with high temporal resolution and accuracy, provided that they are properly installed and calibrated and operated with site-specific parameters. Finally, the synergy of ground radiometers with instruments on board other Copernicus satellites should be further investigated to ensure redundancy and diversity of the produced values for the integrated water vapor.