Patrick Goodwill

Prof. Patrick Goodwill

Magnetic Insight, Inc., Alameda, California, USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2018 in ACS Nano
Verified
Journal Article
Closed access
ZTZhi Wei Tay
Zhi Wei Tay
PCPrashant Chandrasekharan
Prashant Chandrasekharan
ACAndreina Chiu-Lam
Andreina Chiu-Lam
DHDaniel W. Hensley
Daniel W. Hensley
RDRohan Dhavalikar
Rohan Dhavalikar
SCSteven M. Conolly
Steven M. Conolly

7 June 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PGPatrick Goodwill
Patrick Goodwill
SCSteven M. Conolly
Steven M. Conolly
The magnetic particle imaging (MPI) imaging process is a new method of medical imaging with great promise. In this paper we derive the 1-D MPI signal, resolution, bandwidth requirements, signal-to-noise ratio (SNR), specific absorption rate, and slew rate limitations. We conclude with experimental data measuring the point spread function for commercially available SPIO nanoparticles and a demonstration of the principles behind 1-D imaging using a static offset field. Despite arising from the nonlinear temporal response of a magnetic nanoparticle to a changing magnetic field, the imaging process is linear in the magnetization distribution and can be described as a convolution. Reconstruction in one dimension is exact and has a well-behaved quasi-Lorentzian point spread function. The spatial resolution improves cubically with increasing diameter of the SPIO domain, inverse to absolute temperature, linearly with saturation magnetization, and inversely with gradient. The bandwidth requirements approach a megahertz for reasonable imaging parameters and millimeter scale resolutions, and the SNR increases with the scanning rate. The limit to SNR as we scale MPI to human sizes will be patient heating. SAR and magnetostimulation limits give us surprising relations between optimal scanning speeds and scanning frequency for different types of scanners.

16 March 2014 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
MSMikhail G. Shapiro
Mikhail G. Shapiro
PGPatrick Goodwill
Patrick Goodwill
ANArkosnato Neogy
Arkosnato Neogy
MYMelissa Yin
Melissa Yin
FFF. Stuart Foster
F. Stuart Foster
SCSteven M. Conolly
Steven M. Conolly
Ultrasound is among the most widely used non-invasive imaging modalities in biomedicine1, but plays a surprisingly small role in molecular imaging due to a lack of suitable molecular reporters on the nanoscale. Here, we introduce a new class of reporters for ultrasound based on genetically encoded gas nanostructures from microorganisms, including bacteria and archaea. Gas vesicles are gas-filled protein-shelled compartments with typical widths of 45–250 nm and lengths of 100–600 nm that exclude water and are permeable to gas2,3. We show that gas vesicles produce stable ultrasound contrast that is readily detected in vitro and in vivo, that their genetically encoded physical properties enable multiple modes of imaging, and that contrast enhancement through aggregation permits their use as molecular biosensors.

16 February 2017 in Nano Letters
Verified
Journal Article
Closed access
EYElaine Y. Yu
Elaine Y. Yu
MBMindy Bishop
Mindy Bishop
BZBo Zheng
Bo Zheng
RFR. Matthew Ferguson
R. Matthew Ferguson
AKAmit P. Khandhar
Amit P. Khandhar
SCSteven M. Conolly
Steven M. Conolly

10 March 2011 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PGPatrick Goodwill
Patrick Goodwill
SCSteven M. Conolly
Steven M. Conolly
Magnetic particle imaging (MPI) is a promising new medical imaging tracer modality with potential applications in human angiography, cancer imaging, in vivo cell tracking, and inflammation imaging. Here we demonstrate both theoretically and experimentally that multidimensional MPI is a linear shift-invariant imaging system with an analytic point spread function. We also introduce a fast image reconstruction method that obtains the intrinsic MPI image with high signal-to-noise ratio via a simple gridding operation in x-space. We also demonstrate a method to reconstruct large field-of-view (FOV) images using partial FOV scanning, despite the loss of first harmonic image information due to direct feedthrough contamination. We conclude with the first experimental test of multidimensional x-space MPI.

1 April 2013 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
ESEmine U. Saritas
Emine U. Saritas
PGPatrick Goodwill
Patrick Goodwill
LCLaura R. Croft
Laura R. Croft
JKJustin J. Konkle
Justin J. Konkle
KLKuan Lu
Kuan Lu
SCSteven M. Conolly
Steven M. Conolly