The sensing of gravity has emerged as a tool in geophysics applications such as engineering and climate research1–3, including the monitoring of temporal variations in aquifers4 and geodesy5. However, it is impractical to use gravity cartography to resolve metre-scale underground features because of the long measurement times needed for the removal of vibrational noise6. Here we overcome this limitation by realizing a practical quantum gravity gradient sensor. Our design suppresses the effects of micro-seismic and laser noise, thermal and magnetic field variations, and instrument tilt. The instrument achieves a statistical uncertainty of 20 E (1 E = 10−9 s−2) and is used to perform a 0.5-metre-spatial-resolution survey across an 8.5-metre-long line, detecting a 2-metre tunnel with a signal-to-noise ratio of 8. Using a Bayesian inference method, we determine the centre to ±0.19 metres horizontally and the centre depth as (1.89 −0.59/+2.3) metres. The removal of vibrational noise enables improvements in instrument performance to directly translate into reduced measurement time in mapping. The sensor parameters are compatible with applications in mapping aquifers and evaluating impacts on the water table7, archaeology8–11, determination of soil properties12 and water content13, and reducing the risk of unforeseen ground conditions in the construction of critical energy, transport and utilities infrastructure14, providing a new window into the underground.
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
1 November 1996 in Journal of the Optical Society of America A
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
Recent advances in the understanding and control of cold atom systems have resulted in devices with extraordinary metrological performance. To further improve the performance in these systems, additional methods of noise reduction are needed. Here, we examine the noise reduction possible from vacuum compatible low reflection coatings in cold atom systems by characterizing a black coating and its compatibility in a Magneto-Optical Trap (MOT). We demonstrate that the commercially available PCO35® coating provides low-reflectivity surfaces that are ultra-high vacuum compatible. The reflective properties of the coating are compared to titanium, a common vacuum chamber material, and the reduction to scattered light is characterized over a range of angles and wavelengths. The outgassing properties of the coating are measured to be less than that of the vacuum system used to test the coating, which is limited to 3 × 10−8 mbar L cm−2 s−1. The coating is applied to a vacuum chamber housing a rubidium prism MOT, and its vacuum compatibility is assessed and compared to an identical non-coated system. Finally, the effect of scattered light reduction in a generalized system is explored theoretically. These results show promise for reducing background light in cold atom experiments via the use of low-reflectivity coatings.
Ellipse fitting is a technique which is used to extract differential phase in cold-atom interferometers, particularly in situations where common-mode noise needs to be suppressed. We use numerical simulation to investigate errors in the ellipse fitting process; specifically, errors due to the presence of additive noise, linear drift in ellipse offset and amplitude, as well as an error that can arise from fringe normalisation. Errors are found to manifest in two ways: bias in the ellipse phase measurement and incomplete suppression of common mode phase noise. We quantify these errors for three different ellipse fitting algorithms and discuss the applicability of these results to future cold atom sensors.