It is very important to design a rapid and sensitive device for the creatinine concentration detection due to it being one of the most considerable benchmarks for efficient kidney working. Here, a novel biophotonic sensor using one-dimensional ternary PC based on Si/TiN/SiO2 layers is proposed for the creatinine concentration detection in a blood serum sample. A central cavity layer is inserted between two equal periodic numbers. The blood sample can be infiltrated in the cavity layer with various creatinine concentrations. Based on the technique of transfer matrix, the transmittance spectra properties are investigated. The influences of variation of the incidence angle for both TE and TM polarizations and the cavity layer thickness are carefully investigated to attain the best sensitivity of the biophotonic detector. A high sensitivity of 938.02 nm/RIU is realized for the suggested detector, which is comparable to most recent works published in this area. Moreover, the proposed sensor has an inexpensive cost, real-time detection, and simple structure, which is helpful to the industrial design using low-cost product nanofabrication techniques. Based on above-mentioned outcomes, our biosensor candidate is a suitable and effective device for the detection of creatinine concentration, and it can use for any biological sample.
We introduce structures of sensors based on defective one-dimensional quinary photonic crystals. The unit cell of the structure is composed of five layers of N-BAF10 / KNbO3 / TiO2 / KNbO3 / N-BAF10, whereas blood cells under investigation are supposed to construct a defective layer in the middle of the structure. The basic principle of detection of the proposed sensor is based on the existence of the resonant mode, within the photonic bandgap of the transmittance spectrum, due to the presence of blood cells in the defect layer. We found that the characteristics of the resonant mode are dependent on the type of blood cells used, thickness of the defect layer, and the angle of incidence of radiation. The average values of sensitivity, quality factor, and figure of merit for all types of cancerous blood cells are found to be about 623 nm / RIU, 129,560, and 73,950, respectively, at normal incidence. These values increased to 717 nm / RIU, 426,000, and 318,600, respectively, as the angle of incident increased from 0 deg to 45 deg with a low limit of detection of 1.998 × 10 − 7 at 45 deg. Our results indicate that the proposed structures are very efficient in sensing and identifying the type of cancerous blood cells.