Radu Gabriel Vatasescu

Dr. Radu Gabriel Vatasescu

Emergency Clinical Hospital, Bucharest, Romania
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2021 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
AVAura Vîjîiac
Aura Vîjîiac
SOSebastian Onciul
Sebastian Onciul
CGClaudia Guzu
Claudia Guzu
VVVioleta Verinceanu
Violeta Verinceanu
VBVlad Bătăilă
Vlad Bătăilă
MDMaria Dorobanţu
Maria Dorobanţu

30 January 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
RVRadu Gabriel Vatasescu
Radu Gabriel Vatasescu
SPSteliana Cosmina Paja
Steliana Cosmina Paja
ISIoana Sus
Ioana Sus
SCsimona Cainap
simona Cainap
SMStefana Maria Moisa
Stefana Maria Moisa
Eliza CintezaEliza Cinteza
Eliza Cinteza
Wolf–Parkinson–White (WPW) syndrome is a disorder characterized by the presence of at least one accessory pathway (AP) that can predispose people to atrial/ventricular tachyarrhythmias and even sudden cardiac death. It is the second most common cause of paroxysmal supraventricular tachycardia in most parts of the world, affecting about 0.1–0.3% of the general population. Most patients with WPW syndrome have normal anatomy, but it may be associated with concomitant congenital heart disease or systemic diseases. Although many individuals are asymptomatic, during supraventricular arrhythmia episodes, they may experience severe symptoms, including syncope or even sudden cardiac death (mainly due to pre-excited atrial fibrillation over rapidly conducting AP). In addition to arrhythmia-related symptoms, for some specific locations of the APs with overt anterograde conduction, there might be a reduction in exercise capacity mediated by a reduction in LV systolic performance due to anomalous LV depolarization. Although it is typically diagnosed through electrocardiography (ECG), additional tests are necessary for risk assessment. Management of WPW syndrome may be quite challenging and can vary from only acknowledging the presence of the accessory pathway to pharmacological treatment or radiofrequency ablation. Early diagnosis, risk assessment, and appropriate treatment are critical steps in the management of WPW syndrome, aiming to improve the quality of life and reduce the risk of life-threatening arrhythmias.

30 March 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
GFGiulio Falasconi
Giulio Falasconi
DPDiego Penela
Diego Penela
DSDavid Soto-Iglesias
David Soto-Iglesias
PFPietro Francia
Pietro Francia
ASAndrea Saglietto
Andrea Saglietto
ABAntonio Berruezo
Antonio Berruezo
Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.

Verified
Journal Article
Open access
PDF file
MDMohamed Dardari
Mohamed Dardari
Eliza CintezaEliza Cinteza
Eliza Cinteza
Corina Maria VasileCorina Maria Vasile
Corina Maria Vasile
PPPaul Padovani
Paul Padovani
RVRadu Gabriel Vatasescu
Radu Gabriel Vatasescu
Infective endocarditis (IE) is a disease of the endocardium, which leads to the appearance of vegetation on the valves, cardiac structures, or, potentially, vascular endothelium of the heart. The risk of IE can be increased more than 140 times by congenital heart disease (50–59% of all IE), particularly if cyanotic. An increase in mortality may result from IE in patients with a complex cardiac pathology or patients with an implanted prosthetic material, most frequently conduits in a pulmonary position. Cardiac implantable electronic devices (CIED) infective endocarditis is a life-threatening complication representing 10% of all cases of endocarditis. Common signs of presentation are often fever and chills; redness and swelling at the pocket of the pacemaker, including the erosion and exteriorization of the device; and life-threatening sepsis. The use of intracardiac echocardiography for the diagnosis of IE is an innovative method. This may be needed, especially in older children undergoing complex cardiac surgery, when transthoracic echocardiography (TTE) and transesophageal echocardiography (TOE) failed to provide a reliable diagnosis. The 2018 European Heart Rhythm Association (EHRA) experts’ consensus statement on transvenous lead extraction recommends complete device removal and antimicrobial therapy for any device-related infection, including CIED-IE. The most detected microorganism was Staphylococcus Aureus. In addition, cardiac surgery and interventional cardiology associated with the placement of prostheses or conduits may increase the risk of IE up to 1.6% for Melody valve implantation. Our manuscript presents a comprehensive review of infective endocarditis associated with cardiac devices and prostheses in the pediatric population, including recent advances in diagnosis and management.

28 January 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
AVAura Vijiiac
Aura Vijiiac
ASAlina Scarlatescu
Alina Scarlatescu
IPIoana Gabriela Petre
Ioana Gabriela Petre
CVCristian Vîjîiac
Cristian Vîjîiac
RVRadu Gabriel Vatasescu
Radu Gabriel Vatasescu
Atrioventricular coupling has recently emerged as an outcome predictor. Our aim was to assess, through three-dimensional (3D) echocardiography, the role of the left atrioventricular coupling index (LACI), right atrioventricular coupling index (RACI) and a novel combined atrioventricular coupling index (CACI) in a cohort of patients with dilated cardiomyopathy (DCM). One hundred twenty-one consecutive patients with DCM underwent comprehensive 3D echocardiographic acquisitions. LACI was defined as the ratio between left atrial and left ventricular 3D end-diastolic volumes. RACI was defined as the ratio between right atrial and right ventricular 3D end-diastolic volumes. CACI was defined as the sum of LACI and RACI. Patients were prospectively followed for death, heart transplant, nonfatal cardiac arrest and hospitalization for heart failure. Fifty-five patients reached the endpoint. All three coupling indices were significantly more impaired in patients with events, with CACI showing the highest area under the curve (AUC = 0.66, p = 0.003). All three indices were independent outcome predictors when tested in multivariable Cox regression (HR = 2.62, p = 0.01 for LACI; HR = 2.58, p = 0.004 for RACI; HR = 2.37, p = 0.01 for CACI), but only CACI showed an incremental prognostic power over traditional risk factors such as age, left ventricular strain, right ventricular strain and mitral regurgitation severity (likelihood ratio χ2 test = 28.2, p = 0.03). CACI assessed through 3D echocardiography, reflecting both left and right atrioventricular coupling, is an independent predictor of adverse events in DCM, yielding an incremental prognostic power over traditional risk factors.

9 December 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
RMRaluca-Elena Mitran
Raluca-Elena Mitran
PNPopa- Fotea Nicoleta-Monica
Popa- Fotea Nicoleta-Monica
CICorneliu Nicolae Iorgulescu
Corneliu Nicolae Iorgulescu
ANAlexandrina Nastasa
Alexandrina Nastasa
APAdelina Pupaza
Adelina Pupaza
RVRadu Gabriel Vatasescu
Radu Gabriel Vatasescu
Atrial fibrillation (AF), the most frequently encountered arrhythmia worldwide, is associated with increased cardiovascular morbidity and mortality. Left atrial (LA) and antral region of the pulmonary veins (PVs) remodeling are risk factors for AF perpetuation. Among the methods of LA fibrosis quantification, bipolar voltage mapping during three-dimensional electro-anatomical mapping is less studied. The main aim of this study was to analyze the relationship between the degree of LA fibrosis quantified in low-voltage areas and the efficacy of AF radiofrequency catheter ablation. All consecutive patients with AF ablation were included, and the degree of LA fibrosis was measured based on the low-voltage areas in the LA and the antral region of PVs (<0.5 mV for patients in sinus rhythm and <0.25 mV for patients in AF at the time of the ablation procedure). The efficacy of AF ablation was determined by the rate of recurrence after a blanking period of three months. A total of 106 patients were included; from these, 38 (35.8%) had AF recurrence after RF ablation, while 68 (64.2%) were free of events. The area and percentage of LA fibrosis were significantly higher in the patients with AF recurrence (p = 0.018 and p = 0.019, respectively). However, no significant differences were found between the patients with and without AF recurrence in terms of the area and percentage of PVs fibrosis (p = 0.896 and p = 0.888, respectively). Moreover, LA fibrosis parameters proved to be excellent predictors for AF recurrence (areas under the curve of 0.834 and 0.832, respectively, p < 0.001) even after adjustment for LA indexed volume and CHA2DS2-VASc score. In conclusion, LA fibrosis measured on bipolar voltage maps increases the risk of AF recurrence after the RF catheter ablation procedure.