İbrahim Murat Afat

Dr. İbrahim Murat Afat

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
İAİbrahim Murat Afat
İbrahim Murat Afat
EAEmine Tuna Akdoğan
Emine Tuna Akdoğan
OGOnur Gönül
Onur Gönül

1 February 2019 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
İAİbrahim Murat Afat
İbrahim Murat Afat
EAEmine Tuna Akdoğan
Emine Tuna Akdoğan
OGOnur Gönül
Onur Gönül

23 November 2022 in Life
Verified
Journal Article
Open access
PDF file
OGonur gonul
onur gonul
AÇAhmet Çicek
Ahmet Çicek
İAİbrahim Murat Afat
İbrahim Murat Afat
EAEmine Tuna Akdoğan
Emine Tuna Akdoğan
OAOnur ATALI
Onur ATALI
The aim of this study is to examine the effect of unilaterally more posterior placement of implants (Straumann BLT 4.1 mm in diameter and 12 mm long) applied according to the all-on-four concept on the stress distribution on bone, implants, and other prosthetic components, using the finite element analysis method. Three scenarios were modelled: For Model 1 (M1), anterior implants were placed symmetrically perpendicular to the bone in the right and left lateral incisor region, while the necks of the posterior implants placed symmetrically in the second premolar region were angled at 30 degrees. For Model 2 (M2) the implant in the left second premolar region was placed to the first molar region unilaterally. For Model 3 (M3) the implant in the left lateral incisor region was placed to the canine region unilaterally. Vertical and oblique forces (100 N) were applied in the right first molar region. The von Mises and maximum (Pmax) and minimum (Pmin) principal stresses were obtained. The highest stress concentration on the cortical bone was observed in the second premolar region in all models when oblique forces were applied. M1 was highest (8.992 MPa) followed closely by M3 (8.780 MPa) and M2 was lowest (3.692 MPa). The highest stress concentration on the prosthetic parts was observed in this framework when oblique forces were applied. M2 was highest (621.43 MPa) followed by M3 (409.16 MPa) and the lowest was M1 (309.43 MPa). It is thought that placing the implant further posterior to first molar region may prevent the bone resorption that occurs with high stress around the crestal bone. However, increased stress on the implants and prosthetic parts may lead to failures.

14 October 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
İAİbrahim Murat Afat
İbrahim Murat Afat
OGOnur Gönül
Onur Gönül
TSTülin Satılmış
Tülin Satılmış
Postoperative pain is a significant challenge in oral surgery. Tramadol exhibits both systemic and local analgesic effects, with proven efficacy in combination with local anesthetics. This study evaluated the efficacy of local anesthetics combined with tramadol in reducing pain and analgesic use after third molar surgery. This randomized, double-blind trial included ASA I–II patients aged 18–50 years and weighing 70–80 kg who were undergoing impacted third molar surgery. Patients requiring extra anesthesia, those with tramadol hypersensitivity, or those who recently used sedatives were excluded. Two local anesthetic solutions were compared: the LT group (tramadol and articaine with epinephrine) and the LA group (articaine with epinephrine, control). Postoperative pain was measured as the primary outcome via a visual analog scale (VAS) at multiple time points (10 min and 1, 2, 4, 6, 12, 24 and 48 h postsurgery). The secondary outcomes included the timing of the first analgesic intake and the total number of analgesic doses consumed within 48 h. The covariates included age, sex, BMI, surgical duration, and adverse effects (nausea, vomiting, burning). Age and surgical duration were analyzed with t tests; VAS scores and analgesic use were analyzed with Mann–Whitney U tests; and categorical data were analyzed with Fisher’s exact test or Yates’ correction (p < 0.01). Sixty patients were randomized into the LT (n = 30) and LA (n = 30) groups. Age, sex, and BMI distributions were similar between the groups. VAS pain scores were lower in the LT group at 1, 2, and 6 h (mean difference: -4.9, -1.9, and − 1.4; p < 0.01) but higher at 4 h (mean difference: 1.5; p < 0.01). The LT group required their first analgesic later (5.2 ± 0.8 vs. 2.0 ± 0.6 h; mean difference: 3.1; p < 0.01) and consumed fewer analgesics (1.8 ± 0.5 vs. 3.6 ± 0.8 doses; mean difference: -1.8; p < 0.01). A transient higher VAS score was observed at 4 h in the LT group, likely reflecting delayed analgesic use. Adverse effects were minimal and not significantly different between groups. Local anesthetics combined with tramadol reduce pain and analgesic use after third molar surgery. This strategy improves recovery and warrants further research for broader applications. ClinicalTrials.gov NCT05614440, Date of registration 14 November 2022.

4 November 2026 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
EDErkin Doğan
Erkin Doğan
OGonur gonul
onur gonul
İAİbrahim Murat Afat
İbrahim Murat Afat
EKEdip Eren Kadıkıran
Edip Eren Kadıkıran
CTCem Berk Türk
Cem Berk Türk
ADAlpay Demir
Alpay Demir