In the present study, the effects of heating or cooling of the water surface in an open channel were investigated experimentally. The experiments were performed in a horizontal open channel, which was filled with water, to study the temperature and density fields of water, when a part of the surface receives or loses energy (heating or cooling). Initially, the effect of the water surface heating was investigated. The intensity of the thermal radiation was adjusted with the help of a dimmer and the produced velocities were measured in a two-dimensional field with the help of a camera and a dye (rhodamine). This method determined the range of flow velocities at different times in selected areas. This field will be time-varying until thermal equilibrium is reached and the flow becomes steady. The effect of the water surface cooling was then investigated in a similar way. The flow field in this case remains variable until the refrigerant load (ice columns) is finished. A waterproof digital pin thermometer was used to measure the temperature field and water density was measured by a densimeter. The results showed that the flow velocities developed by heating are much lower than those developed by cooling.
In this study the effect of cooling load on the surface water of an open channel with different flow depths is investigated. The method, which was used, involves an experimental laboratory set-up that contains a well-insulated cooling load over a finite area of the water surface, without direct contact with the free water surface so that losses of load to the environment should be avoided. The different cooling loads for each experiment were achieved with the use of insulating films. The insulating film is placed at the bottom of the experimental set-up where there was an empty surface (gap - D), through which the cooling load is allowed to pass. The measurement of velocities was carried out at a two-dimensional (XZ) field, with the help of a digital camera. The recording of motion of the dye (rhodamine) along the channel per unit of time, allows the calculation of the values of the velocity fields. Measurements were conducted when the phenomenon becomes steady. The results for the determination of the cold mass length as a function of the flow depth, and the temperature difference ΔT, in a state of thermal equilibrium, led to the formation of a new mathematical relationship. Further study of the phenomenon is essential for the improvement of this study, in combination with other parameters that affect the aquatic ecosystem.
This study develops and applies a mathematical model to simulate the fluid dynamics of an open channel subjected to a localized cooling load at the water surface. The model is designed to compute and produce the velocity and temperature fields generated by this surface cooling effect. Laboratory experiments were also conducted to support the investigation and to complement the numerical analysis. The mathematical formulation is based on the conservation equations of mass and momentum, together with an advection–diffusion equation for a transported substance expressed through water density. The governing equations are solved numerically using the finite difference method. Thus, the flow is computed using the velocity of the currents. In parallel, water density is computed, after which water temperature is obtained from an experimentally established density–temperature relationship. The study results in the temperature distribution and the two-dimensional velocity field generated by density and temperature differences induced by the local surface cooling load. The numerical results are reported to be in good agreement with the laboratory measurements.