AMoRE searches for the neutrinoless double beta decay using 100 kg of enriched ^{100}Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. AMoRE-I is a demonstrator for the full-scale AMoRE, operated at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg year (or 3.89 kg_{^{100}Mo} year), and the total background rate near the Q value was 0.025±0.002 counts/keV/kg/year. We observed no indication of 0νββ decay and report a new lower limit of the half-life of ^{100}Mo 0νββ decay as T_{1/2}^{0ν}>2.9×10^{24} yr at 90% confidence level. The effective Majorana mass limit range is m_{ββ}<(210-610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.
28 April 2017 in Journal of Materials Science and Engineering B
The precursors’ purity is one of the main factors when growing crystals with predetermined functional properties. Impurities composition greatly influence optical properties, radiation hardness and decay time of scintillation crystals and directly relates to crystal’s own radiation background. On an example of Bi4Ge3O12 (BGO) crystal growth dependence of optical and scintillating properties and radiation hardness from growth technique and the purity of initial bismuth oxide Bi2O3 was shown. In general the goal of obtaining crystals for rear events registration is an even more complex problem. At one hand one has to obtain crystals with the best scintillation properties, at another hand their own radiation background has to be extremely low, especially in a group of elements such as K. Besides that, due to a high cost of isotopically-enriched materials maximal utilization of compound during growth process and recuperation of residuals after growth and cutting with minimal material losses is strictly required.
We report on the development of scintillating bolometers based on lithium molybdate crystals that contain molybdenum that has depleted into the double- active isotope Mo (LiMoO). We used two LiMoO cubic samples, each of which consisted of 45-millimeter sides and had a mass of 0.28 kg; these samples were produced following the purification and crystallization protocols developed for double- search experiments with Mo-enriched LiMoO crystals. Bolometric Ge detectors were utilized to register the scintillation photons that were emitted by the LiMoO crystal scintillators. The measurements were performed in the CROSS cryogenic set-up at the Canfranc Underground Laboratory (Spain). We observed that the LiMoO scintillating bolometers were characterized by an excellent spectrometric performance (∼3–6 keV of FWHM at 0.24–2.6 MeV s), moderate scintillation signal (∼0.3–0.6 keV/MeV scintillation-to-heat energy ratio, depending on the light collection conditions), and high radiopurity (Th and Ra activities are below a few µBq/kg), which is comparable with the best reported results of low-temperature detectors that are based on LiMoO using natural or Mo-enriched molybdenum content. The prospects of LiMoO bolometers for use in rare-event search experiments are briefly discussed.