V.D. Grigoryeva

Dr. V.D. Grigoryeva


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2025 in Physical Review Letters
Verified
Journal Article
Closed access
AAA Agrawal
A Agrawal
VAV V Alenkov
V V Alenkov
PAP Aryal
P Aryal
JBJ Beyer
J Beyer
BBB Bhandari
B Bhandari
ACAMoRE Collaboration
AMoRE Collaboration
AMoRE searches for the neutrinoless double beta decay using 100 kg of enriched ^{100}Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. AMoRE-I is a demonstrator for the full-scale AMoRE, operated at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg year (or 3.89 kg_{^{100}Mo} year), and the total background rate near the Q value was 0.025±0.002 counts/keV/kg/year. We observed no indication of 0νββ decay and report a new lower limit of the half-life of ^{100}Mo 0νββ decay as T_{1/2}^{0ν}>2.9×10^{24} yr at 90% confidence level. The effective Majorana mass limit range is m_{ββ}<(210-610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.

28 April 2017 in Journal of Materials Science and Engineering B
Verified
Journal Article
Open access
VGV.D. Grigoryeva
V.D. Grigoryeva
VSVladimir Shlegel
Vladimir Shlegel
TBTatyana Bekker
Tatyana Bekker
NINina Ivannikova
Nina Ivannikova
AGAndrea Giuliani
Andrea Giuliani
FDFedor Danevich
Fedor Danevich

1 December 2020 in Journal of Crystal Growth
Verified
Journal Article
Closed access
VGV.D. Grigoryeva
V.D. Grigoryeva
VSV.N. Shlegel
V.N. Shlegel
YBYu.A. Borovlev
Yu.A. Borovlev
BTBekker Tatyana
Bekker Tatyana
ABA.S. Barabash
A.S. Barabash
OMO.I. Meshkov
O.I. Meshkov

1 January 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
VGV.D. Grigoryeva
V.D. Grigoryeva
NINina Ivannikova
Nina Ivannikova
IIIgor Ivanov
Igor Ivanov
EMEvgenii Makarov
Evgenii Makarov
INIgor Novoselov
Igor Novoselov
VSVladimir Shlegel
Vladimir Shlegel
The precursors’ purity is one of the main factors when growing crystals with predetermined functional properties. Impurities composition greatly influence optical properties, radiation hardness and decay time of scintillation crystals and directly relates to crystal’s own radiation background. On an example of Bi4Ge3O12 (BGO) crystal growth dependence of optical and scintillating properties and radiation hardness from growth technique and the purity of initial bismuth oxide Bi2O3 was shown. In general the goal of obtaining crystals for rear events registration is an even more complex problem. At one hand one has to obtain crystals with the best scintillation properties, at another hand their own radiation background has to be extremely low, especially in a group of elements such as K. Besides that, due to a high cost of isotopically-enriched materials maximal utilization of compound during growth process and recuperation of residuals after growth and cutting with minimal material losses is strictly required.

9 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
IBIulian Bandac
Iulian Bandac
Alexander BarabashAlexander Barabash
Alexander Barabash
LBLaurent Bergé
Laurent Bergé
YBYury A. Borovlev
Yury A. Borovlev
JCJosé Maria Calvo-Mozota
José Maria Calvo-Mozota
AZA. Zolotarova
A. Zolotarova
We report on the development of scintillating bolometers based on lithium molybdate crystals that contain molybdenum that has depleted into the double-β active isotope 100Mo (Li2100deplMoO4). We used two Li2100deplMoO4 cubic samples, each of which consisted of 45-millimeter sides and had a mass of 0.28 kg; these samples were produced following the purification and crystallization protocols developed for double-β search experiments with 100Mo-enriched Li2MoO4 crystals. Bolometric Ge detectors were utilized to register the scintillation photons that were emitted by the Li2100deplMoO4 crystal scintillators. The measurements were performed in the CROSS cryogenic set-up at the Canfranc Underground Laboratory (Spain). We observed that the Li2100deplMoO4 scintillating bolometers were characterized by an excellent spectrometric performance (∼3–6 keV of FWHM at 0.24–2.6 MeV γs), moderate scintillation signal (∼0.3–0.6 keV/MeV scintillation-to-heat energy ratio, depending on the light collection conditions), and high radiopurity (228Th and 226Ra activities are below a few µBq/kg), which is comparable with the best reported results of low-temperature detectors that are based on Li2MoO4 using natural or 100Mo-enriched molybdenum content. The prospects of Li2100deplMoO4 bolometers for use in rare-event search experiments are briefly discussed.

23 May 2024 in Astroparticle Physics
Verified
Journal Article
Closed access
AAA. Agrawal
A. Agrawal
VAV.V. Alenkov
V.V. Alenkov
PAP. Aryal
P. Aryal
JBJ. Beyer
J. Beyer
BBB. Bhandari
B. Bhandari
QYQ. Yue
Q. Yue