Aims: The GermAn Laser Lead Extraction RegistrY: GALLERY is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. Methods and results: Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. 5499 leads with a median lead dwell time of 96 (62–141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. Conclusion: In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.
Anorexia nervosa is a potentially life-threatening eating disorder, characterized by an abnormally low body weight. This case report illustrates a 22-year old female with cardiac arrest due to a refeeding syndrome in a patient with anorexia nervosa. It features the successful use of extracorporeal cardiopulmonary resuscitation in a case of severe left ventricular dysfunction resulting in a favorable outcome. Conclusion. We present the first case of a cardiac arrest due to a refeeding syndrome in anorexia nervosa featuring the successful use of an extracorporeal cardiopulmonary resuscitation approach as a bridge to full recovery.
Background: The number of young patients receiving ICDs or CRT-Ds has been increasing in recent decades and understanding the key characteristics of this special population is paramount to optimized patient care. Methods: The DEVICE I+II registry prospectively enrolled patients undergoing ICD/CRT-D implantation or revision from 50 German centers between 2007 and 2014 Data on patient characteristics, procedural outcome, adverse events, and mortality during the initial stay and 1-year follow-up were collected. All patients under the age of 45 years were identified and included in a comparative analysis with the remaining population. Results: A total number of 5313 patients were enrolled into the registry, of which 339 patients (6.4%) were under the age of 45 years. Mean age was 35.0 ± 8.2 vs. 67.5 ± 9.7 years, compared to older patients (≥45 years). Young patients were more likely to receive an ICD (90.9 vs. 69.9%, p < 0.001) than a CRT-D device (9.1 vs. 30.1%). Coronary artery disease was less common in younger patients (13.6 vs. 63.9%, p < 0.001), whereas hypertrophic cardiomyopathy (10.9 vs. 2.7%, p < 0.001) and primary cardiac electrical diseases (11.2 vs. 1.5%, p < 0.001) were encountered more often. Secondary preventive ICD was more common in younger patients (51.6 vs. 39.9%, p < 0.001). Among those patients, survival of sudden cardiac death (66.7 vs. 45.4%, p < 0.001) due to ventricular fibrillation (60.6 vs. 37.9%, p < 0.001) was the leading cause for admission. There were no detectable differences in postoperative complications requiring intervention (1.5 vs. 1.9%, p = 0.68) or in-hospital mortality (0.0 vs. 0.3%, p = 0.62). Median follow-up duration was 17.9 [13.4–22.9] vs. 16.9 [13.1–23.1] months (p = 0.13). In younger patients, device-associated complications requiring revision were more common (14.1 vs. 8.3%, p < 0.001) and all-cause 1-year-mortality after implantation was lower (2.9 vs. 7.3%, p = 0.003; HR 0.39, 95%CI: 0.2–0.75) than in older patients. Conclusions: Young patients < 45 years of age received defibrillator therapy more often for secondary prevention. Rates for periprocedural complications and in-hospital mortality were very low and without differences between groups. Young patients have lower mortality during follow-up but experienced a higher rate of postoperative complications requiring revision, potentially due to a more active lifestyle.