Due to the rapid developments in materials science and fabrication techniques, wearable devices have recently received increased attention for biomedical applications, particularly in medical ultrasound imaging, sensing, and therapy. Ultrasound is ubiquitous in biomedical applications because of its non-invasive nature, nonionic radiating, high precision, and real-time capabilities. While conventional ultrasound transducers are rigid and bulky, flexible transducers can be conformed to curved body areas for continuous sensing without restricting tissue movement or transducer shifting. This article comprehensively reviews the application of flexible ultrasound transducers in the field of biomedical imaging, sensing, and therapy. First, we review the background of flexible ultrasound transducers. Following that, we discuss advanced materials and fabrication techniques for flexible ultrasound transducers and their enabling technology status. Lastly, we highlight and summarize some promising preliminary data with recent applications of flexible ultrasound transducers in biomedical imaging, sensing, and therapy. We also provide technical barriers, challenges, and future perspectives for further research and development.
With the rapid advancement of tracking technologies, the applications of tracking systems in ultrasound imaging have expanded across a wide range of fields. In this review article, we discuss the basic tracking principles, system components, performance analyses, as well as the main sources of error for popular tracking technologies that are utilized in ultrasound imaging. In light of the growing demand for object tracking, this article explores both the potential and challenges associated with different tracking technologies applied to various ultrasound imaging applications, including freehand 3D ultrasound imaging, ultrasound image fusion, ultrasound-guided intervention and treatment. Recent development in tracking technology has led to increased accuracy and intuitiveness of ultrasound imaging and navigation with less reliance on operator skills, thereby benefiting the medical diagnosis and treatment. Although commercially available tracking systems are capable of achieving sub-millimeter resolution for positional tracking and sub-degree resolution for orientational tracking, such systems are subject to a number of disadvantages, including high costs and time-consuming calibration procedures. While some emerging tracking technologies are still in the research stage, their potentials have been demonstrated in terms of the compactness, light weight, and easy integration with existing standard or portable ultrasound machines.
9 February 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Among tracking techniques applied in the 3-D freehand ultrasound (US), the camera-based tracking method is relatively mature and reliable. However, constrained by manufactured marker rigid bodies, the US probe is usually limited to operate within a narrow rotational range before occlusion issues affect accurate and robust tracking performance. Thus, this study proposed a hemispherical marker rigid body to hold passive noncoplanar markers so that the markers could be identified by the camera, mitigating self-occlusion. The enlarged rotational range provides greater freedom for sonographers while performing examinations. The single-axis rotational and translational tracking performances of the system, equipped with the newly designed marker rigid body, were investigated and evaluated. Tracking with the designed marker rigid body achieved high tracking accuracy with 0.57° for the single-axis rotation and 0.01 mm for the single-axis translation for sensor distance between 1.5 and 2 m. In addition to maintaining high accuracy, the system also possessed an enhanced ability to capture over 99.76% of the motion data in the experiments. The results demonstrated that with the designed marker rigid body, the missing data were remarkably reduced from over 15% to less than 0.5%, which enables interpolation in the data postprocessing. An imaging test was further conducted, and the volume reconstruction of a four-month fetal phantom was demonstrated using the motion data obtained from the tracking system.
23 September 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Ultrasonic tracking is a promising technique in indoor object localization. However, limited success has been reported in dynamic orientational and positional ultrasonic tracking for ultrasound probes due to its instability and relatively low accuracy. This article aims at developing an inertial measurement unit (IMU) assisted ultrasonic tracking system that enables a high accuracy positional and orientational localization. The system was designed with the acoustic pressure field simulation of the transmitter, receiver configuration, position-variant error simulation, and sensor fusion. The prototype was tested in a tracking volume required in typical obstetric sonography within the typical operation speed ranges (slow mode and fast mode) of ultrasound probe movement. The performance in two different speed ranges was evaluated against a commercial optical tracking device. The results show that the proposed IMU-assisted ultrasound tracking system achieved centimeter-level positional tracking accuracy with the mean absolute error of 12 mm and the mean absolute error of orientational tracking was less than 1°. The results indicate the possibility of implementing the IMU-assisted ultrasonic tracking system in ultrasound probe localization.
Functional electrical stimulation (FES) is a vital method in neurorehabilitation used to reanimate paralyzed muscles, enhance the size and strength of atrophied muscles, and reduce spasticity. FES often leads to increased muscle fatigue, necessitating careful monitoring of the patient’s response. Ultrasound (US) imaging has been utilized to provide valuable insights into FES-induced fatigue by assessing changes in muscle thickness, stiffness, and strain. Current commercial FES electrodes lack sufficient US transparency, hindering the observation of muscle activity beneath the skin where the electrodes are placed. US-compatible electrodes are essential for accurate imaging and optimal FES performance, especially given the spatial constraints of conventional US probes and the need to monitor muscle areas directly beneath the electrodes. This study introduces specially designed body-conforming US-compatible FES (US-FES) electrodes constructed with a silver nanowire/polydimethylsiloxane (AgNW/PDMS) composite. We compared the performance of our body-conforming US-FES electrode with a commercial hydrogel electrode. The findings revealed that our US-FES electrode exhibited comparable conductivity and performance to the commercial one. Furthermore, US compatibility was investigated through phantom and in vivo tests, showing significant compatibility even during FES, unlike the commercial electrode. The results indicated that US-FES electrodes hold significant promise for the real-time monitoring of muscle activity during FES in clinical rehabilitative applications.
16 January 2026 in IEEE Transactions on Instrumentation and Measurement
Precise and time-efficient sensing of tremor dynamics is essential for developing personalized, adaptive stimulation strategies for movement disorders such as Parkinson’s Disease (PD) and Essential Tremor (ET). Existing modalities—such as inertial measurement units (IMUs) and surface electromyography (EMG)—lack muscle specificity and are prone to stimulation artifacts. To address these limitations, we fabricated and applied a Wearable Ultrasound Sensing (WUS) system, featuring dual flexible 64- element transducer arrays with center frequency of 6 MHz conformed over the flexor carpi radialis (FCR) and extensor carpi radialis (ECR) muscles for simultaneous antagonist muscle monitoring. A machine learning (ML) pipeline was introduced to estimate tissue displacement (TD) from raw ultrasound signals. Across three participants and multiple trials, the WUS system achieved tremor frequency detection within 10 %variation relative to commercial B-mode and IMU sensors, and met statistical equivalence thresholds based on two one-sided test (TOST) analysis. The TD estimation models demonstrated high predictive accuracy, with overall Pearson correlation coefficients between predicted and actual values ranging from 0.88 to 0.97, normalized RMSE values below 10 %, and offline model building times under 800 seconds. Compared to classical B-mode speckle tracking, the proposed WUS-ML pipeline reduced offline model building time by 75 % (from 3095 sec to 792 sec). In real-time performance tests, it reduced frame-level latency from 3700 ms to 17 ms and achieved effective processing rates exceeding 50 Hz, well above the Nyquist threshold for tremor analysis. These results demonstrate the feasibility of dual-array wearable ultrasound for accurate, low-latency tremor tracking and lay the groundwork for future closed-loop afferent stimulation systems in both clinical and at-home environments.