Nitin Kumar Saxena

Dr. Nitin Kumar Saxena

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Journal of The Institution of Engineers (India): Series B
Verified
Journal Article
Closed access
PDF file
VGVARUN GUPTA
VARUN GUPTA
MMMonika Mittal
Monika Mittal
VMVikas Mittal
Vikas Mittal
Nitin Kumar SaxenaNitin Kumar Saxena
Nitin Kumar Saxena

1 December 2016 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Nitin Kumar SaxenaNitin Kumar Saxena
Nitin Kumar Saxena
AKAshwani Kumar
Ashwani Kumar

19 May 2022 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
Nitin Kumar SaxenaNitin Kumar Saxena
Nitin Kumar Saxena
DGDavid Wenzhong Gao
David Wenzhong Gao
AKAshwani Kumar
Ashwani Kumar
Saad MekhilefSaad Mekhilef
Saad Mekhilef
VGVARUN GUPTA
VARUN GUPTA

2 January 2023 in Journal of The Institution of Engineers (India): Series B
Verified
Journal Article
Closed access
PDF file
VGVARUN GUPTA
VARUN GUPTA
MMMonika Mittal
Monika Mittal
VMVikas Mittal
Vikas Mittal
SDSourav Diwania
Sourav Diwania
Nitin Kumar SaxenaNitin Kumar Saxena
Nitin Kumar Saxena

25 May 2021 in Sensing and Imaging
Verified
Journal Article
Closed access
PDF file
VGVARUN GUPTA
VARUN GUPTA
MMMonika Mittal
Monika Mittal
VMVikas Mittal
Vikas Mittal
Nitin Kumar SaxenaNitin Kumar Saxena
Nitin Kumar Saxena

18 February 2015 in Electric Power Components and Systems
Verified
Journal Article
Closed access
Nitin Kumar SaxenaNitin Kumar Saxena
Nitin Kumar Saxena
AKAshwani Kumar
Ashwani Kumar
This article presents static and dynamic reactive power compensators together for a self-excited induction generator and synchronous generator based isolated hybrid power system. Reactive power is required for excitation of the induction machine and for load under steady-state and transient state operations in an isolated hybrid power system. For small perturbation of load reactive power and input wind power, the use of a dynamic compensator alone may give better voltage stability but at a high cost; in contrast, the static compensator reduces the cost on compromising with the voltage stability. The proper rating selection of both compensators used may give the optimum solution between the voltage stability as system performance and cost of compensation. The fixed costs and voltage profiles are compared for the different participations of the fixed capacitor bank and STATCOM. The interaction of the dynamic load model is also introduced to make the system more reliable and hence a new power balance equation is derived. A 10% step disturbance in the dynamic load model as well as wind power input is considered for the system study. Four different cases designed for unique participation of static and dynamic reactive power compensators are presented. The analytical comparison is based on cost, rating selection, and voltage stability under transient condition.