Fernando Sanchez

Dr. Fernando Sanchez

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in Journal of Clinical Microbiology
Verified
Journal Article
Closed access
LFLaura Ferreira
Laura Ferreira
FSFernando Sanchez
Fernando Sanchez
MGMagdalena González-Ávila
Magdalena González-Ávila
DCDavid Cembrero-Fuciños
David Cembrero-Fuciños
AHAna Herrero-Hernández
Ana Herrero-Hernández
JBJuan Luis Muñoz Bellido
Juan Luis Muñoz Bellido
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been suggested as a reliable method for bacterial identification from cultures. Direct analysis of clinical samples might increase the usefulness of this method, shortening the time for microorganism identification. We compared conventional methods for the diagnosis of urinary tract infections (UTIs) and identification of the urinary tract pathogens (automated screening, plate cultures, and identification based on biochemical characteristics) and a fast method based on conventional screening and MALDI-TOF MS. For this latter method, 4 ml of urine was centrifuged at a low-revolution setting (2,000 × g ) to remove leukocytes and then at high revolutions (15,500 × g ) to collect bacteria. The pellet was washed and then applied directly to the MALDI-TOF MS plate. Two hundred sixty urine samples, detected as positive by the screening device (UF-1000i), were processed by culture and MALDI-TOF MS. Twenty samples were positive in the screening device but negative in culture, and all of them were also negative by MALDI-TOF MS. Two-hundred thirty-five samples displayed significant growth of a single morphological type in culture. Two-hundred twenty of them showed bacterial growth of >10 5 CFU/ml. Microorganism identifications in this group were coincident at the species level in 202 cases (91.8%) and at the genus level in 204 cases (92.7%). The most frequent microorganism was Escherichia coli (173 isolates). MALDI-TOF MS identified this microorganism directly from the urine sample in 163 cases (94.2%). Our results show that MALDI-TOF MS allows bacterial identification directly from infected urine in a short time, with high accuracy, and especially when Gram-negative bacteria with high bacterial counts are involved.

1 April 2011 in Clinical Microbiology and Infection
Verified
Journal Article
Open access
PDF file
LFL. Ferreira
L. Ferreira
FSFernando Sanchez
Fernando Sanchez
IPI. Porras-Guerra
I. Porras-Guerra
MGM.I. García-García
M.I. García-García
JGJ.E. García-Sánchez
J.E. García-Sánchez
JBJuan Luis Muñoz Bellido
Juan Luis Muñoz Bellido
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows a fast and reliable bacterial identification from culture plates. Direct analysis of clinical samples may increase its usefulness in samples in which a fast identification of microorganisms can guide empirical treatment, such as blood cultures (BC). Three hundred and thirty BC, reported as positive by the automated BC incubation device, were processed by conventional methods for BC processing, and by a fast method based on direct MALDI-TOF MS. Three hundred and eighteen of them yield growth on culture plates, and 12 were false positive. The MALDI-TOF MS-based method reported that no peaks were found, or the absence of a reliable identification profile, in all these false positive BC. No mixed cultures were found. Among these 318 BC, we isolated 61 Gram-negatives (GN), 239 Gram-positives (GP) and 18 fungi. Microorganism identifications in GN were coincident with conventional identification, at the species level, in 83.3% of BC and, at the genus level, in 96.6%. In GP, identifications were coincident with conventional identification in 31.8% of BC at the species level, and in 64.8% at the genus level. Fungaemia was not reliably detected by MALDI-TOF. In 18 BC positive for Candida species (eight C. albicans, nine C. parapsilosis and one C. tropicalis), no microorganisms were identified at the species level, and only one (5.6%) was detected at the genus level. The results of the present study show that this fast, MALDI-TOF MS-based method allows bacterial identification directly from presumptively positive BC in a short time (<30 min), with a high accuracy, especially when GN bacteria are involved.

1 July 2011 in Clinical Microbiology and Infection
Verified
Journal Article
Open access
PDF file
LFL. Ferreira
L. Ferreira
FSFernando Sanchez
Fernando Sanchez
JBJuan Luis Muñoz Bellido
Juan Luis Muñoz Bellido
JGJ. M. González‐Buitrago
J. M. González‐Buitrago
Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is a fast and reliable technology for the identification of microorganisms with proteomics approaches. Here, we compare an intact cell method and a protein extraction method before application on the MALDI plate for the direct identification of microorganisms in both urine and blood culture samples from clinical microbiology laboratories. The results show that the intact cell method provides excellent results for urine and is a good initial method for blood cultures. The extraction method complements the intact cell method, improving microorganism identification from blood culture. Thus, we consider that MALDI-TOF MS performed directly on urine and blood culture samples, with the protocols that we propose, is a suitable technique for microorganism identification, as compared with the routine methods used in the clinical microbiology laboratory.

1 May 2009 in International Dairy Journal
Verified
Journal Article
Closed access
FSFernando Sanchez
Fernando Sanchez
JAJ.M. Alonso
J.M. Alonso
LZL. Zancada
L. Zancada
PHP. Hueso
P. Hueso

31 May 2011 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LFLaura Ferreira
Laura Ferreira
FSFernando Sanchez
Fernando Sanchez
PFPaula Garcia Fraile
Paula Garcia Fraile
RRRaúl Rivas
Raúl Rivas
PMPedro F Mateos
Pedro F Mateos
EVEncarna Velazquez
Encarna Velazquez
Family Rhizobiaceae includes fast growing bacteria currently arranged into three genera, Rhizobium, Ensifer and Shinella, that contain pathogenic, symbiotic and saprophytic species. The identification of these species is not possible on the basis of physiological or biochemical traits and should be based on sequencing of several genes. Therefore alternative methods are necessary for rapid and reliable identification of members from family Rhizobiaceae. In this work we evaluated the suitability of Matrix-Assisted Laser Desorption Ionization-Time-of-Flight Mass Spectrometry (MALDI-TOF MS) for this purpose. Firstly, we evaluated the capability of this methodology to differentiate among species of family Rhizobiaceae including those closely related and then we extended the database of MALDI Biotyper 2.0 including the type strains of 56 species from genera Rhizobium, Ensifer and Shinella. Secondly, we evaluated the identification potential of this methodology by using several strains isolated from different sources previously identified on the basis of their rrs, recA and atpD gene sequences. The 100% of these strains were correctly identified showing that MALDI-TOF MS is an excellent tool for identification of fast growing rhizobia applicable to large populations of isolates in ecological and taxonomic studies.

6 December 2010 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LFLaura Ferreira
Laura Ferreira
SCSilvia Vega Castaño
Silvia Vega Castaño
FSFernando Sanchez
Fernando Sanchez
SGSandra González-Cabrero
Sandra González-Cabrero
FMFabiola Menegotto
Fabiola Menegotto
JBJuan Luis Muñoz Bellido
Juan Luis Muñoz Bellido
MALDI-TOF mass spectrometry (MS) is a reliable method for bacteria identification. Some databases used for this purpose lack reference profiles for Brucella species, which is still an important pathogen in wide areas around the world. We report the creation of profiles for MALDI-TOF Biotyper 2.0 database (Bruker Daltonics, Germany) and their usefulness for identifying brucellae from culture plates and blood cultures. We created MALDI Biotyper 2.0 profiles for type strains belonging to B. melitensis biotypes 1, 2 and 3; B. abortus biotypes 1, 2, 5 and 9; B. suis, B. canis, B ceti and B. pinnipedialis. Then, 131 clinical isolates grown on plate cultures were used in triplicate to check identification. Identification at genus level was always correct, although in most cases the three replicates reported different identification at species level. Simulated blood cultures were performed with type strains belonging to the main human pathogenic species (B. melitensis, B. abortus, B. suis and B. canis), and studied by MALDI-TOF MS in triplicate. Identification at genus level was always correct. MALDI-TOF MS is reliable for Brucella identification to the genus level from culture plates and directly from blood culture bottles.