Neurons of the peripheral nervous system retain the intrinsic capability of regenerate their axons after injury, by triggering a complex activation response. This genetic switch is dependent of signals from the injured axon. Schwann cells (SCs) in the distal stump of an injured nerve also play an active role in the local regulation of axonal programs, by using cell-to-cell contacts but also secreted signals, the so-called secretome. Secretome contains all the proteins (cytokines, growth factors and others) secreted by the cell and includes extracellular vesicles. The released vesicles can transport signaling proteins and both coding and regulatory RNAs, thus facilitating multilevel communication. It is nowadays clear that secretome of SCs is fundamental to both orchestrate Wallerian degeneration and to sustain axonal regeneration. Therefore, the use of secretome has emerged as an alternative to cell therapy in the field of tissue regeneration. In fact, separate components of SC secretome have been extensively used in experimental models to enhance peripheral nerve regeneration after injury. However, the most used secretome in neural therapies has been the one derived from mesenchymal (MSC) or other derived stem cells. In fact, the effects of cell therapy with MSCs have been mainly associated with the secretion of bioactive molecules and extracellular vesicles, which constitute their secretome. In this review, we first describe the role of SC and macrophage secretomes on Wallerian degeneration and axonal regeneration after peripheral nerve injury. Then, we review the different works reported in the literature that have used secretomes of SCs or MSCs in the treatment of peripheral nerve injuries in experimental models, to highlight the use of secretomes as a promising cell-free therapeutic approach, that reduces some of the risks associated with the use of cells, such as tumor formation or rejection.
Despite advances in microsurgery, full functional recovery of severe peripheral nerve injuries is not commonly attained. The sheep appears as a good preclinical model since it presents nerves with similar characteristics to humans. In this study, we induced 5 or 7 cm resection in the peroneal nerve and repaired with an autograft. Functional evaluation was performed monthly. Electromyographic and ultrasound tests were performed at 6.5 and 9 months postoperation (mpo). No significant differences were found between groups with respect to functional tests, although slow improvements were seen from 5 mpo. Electrophysiological tests showed compound muscle action potentials (CMAP) of small amplitude at 6.5 mpo that increased at 9 mpo, although they were significantly lower than the contralateral side. Ultrasound tests showed significantly reduced size of tibialis anterior (TA) muscle at 6.5 mpo and partially recovered size at 9 mpo. Histological evaluation of the grafts showed good axonal regeneration in all except one sheep from autograft 7 cm (AG7) group, while distal to the graft there was a higher number of axons than in control nerves. The results indicate that sheep nerve repair is a useful model for investigating long-gap peripheral nerve injuries.
Decellularized nerve allografts are an alternative to autograft for repairing severe nerve injuries, since they have higher availability and do not induce rejection. In this study, we have assessed the regenerative potential of a novel decellularization protocol for human and rat nerves for repairing nerve resections, compared to the gold standard autograft. A 15-mm gap in the sciatic nerve was repaired with decellularized rat allograft (DC-RA), decellularized human xenograft (DC-HX), or fresh autograft (AG). Electrophysiology tests were performed monthly to evaluate muscle reinnervation, whereas histological and immunohistochemical analyses of the grafts were evaluated at 4 months. A short-term study was also performed to compare the differences between the two decellularized grafts (DC-RA and DC-HX) in early phases of regeneration. The decellularization process eliminated cellularity while preserving the ECM and endoneurial tubules of both rat and human nerves. Higher amount of reinnervation was observed in the AG group compared to the DC-RA group, while only half of the animals of the DC-HX showed distal muscle reinnervation. The density of myelinated axons was significantly higher in AG compared to both DC grafts, being this density significantly higher in DC-RA than in DC-HX. At short term, fibroblasts repopulated the DC-RA graft, supporting regenerated axons, whereas an important fibrotic reaction was observed around DC-HX grafts. In conclusion, the decellularized allograft sustained regeneration through a long gap in the rat although at a slower rate compared to the ideal autograft, whereas regeneration was limited or even failed when using a decellularized xenograft.
Decellularized nerve allografts (DC) are an alternative to autografts (AG) for repairing severe peripheral nerve injuries. We have assessed a new DC provided by VERIGRAFT. The decellularization procedure completely removed cellularity while preserving the extracellular matrix. We first assessed the DC in a 15 mm gap in the sciatic nerve of rats, showing slightly delayed but effective regeneration. Then, we assayed the DC in a 70 mm gap in the peroneal nerve of sheep compared with AG. Evaluation of nerve regeneration and functional recovery was performed by clinical, electrophysiology and ultrasound tests. No significant differences were found in functional recovery between groups of sheep. Histology showed a preserved fascicular structure in the AG while in the DC grafts regenerated axons were grouped in small units. In conclusion, the DC was permissive for axonal regeneration and allowed to repair a 70 mm long gap in the sheep nerve.
Antimicrobial peptides (AMPs) are regarded as a promising alternative to traditional antibiotics in the face of ever-increasing resistance. However, many AMPs fail to progress into clinics due to unexpected difficulties found in preclinical in vivo phases. Our research has focused on crotalicidin (Ctn), an AMP from snake venom, and a fragment thereof, Ctn[15-34], with improved in vitro antimicrobial and anticancer activities and remarkable serum stability. As the retroenantio versions of both AMPs maintained favorable profiles, in this work, we evaluate the in vivo efficacy of both the native-sequence AMPs and their retroenantio counterparts in a murine infection model with Acinetobacter baumannii. A significant reduction in bacterial levels is found in the mice treated with Ctn[15-34]. However, contrary to expectations, the retroenantio analogs either exhibit toxicity or lack efficacy when administered to mice. Our findings underscore the critical importance of in vivo infection model evaluation to fully calibrate the therapeutic potential of AMPs.
BACKGROUND AND OBJECTIVES: Peripheral nerve injuries resulting in a nerve defect require surgical repair. The gold standard of autograft (AG) has several limitations, and therefore, new alternatives must be developed. The main objective of this study was to assess nerve regeneration through a long gap nerve injury (50 mm) in the peroneal nerve of sheep with a decellularized nerve allograft (DCA). METHODS: A 5-cm long nerve gap was made in the peroneal nerve of sheep and repaired using an AG or using a DCA. Functional tests were performed once a month and electrophysiology and echography evaluations at 6.5 and 9 months postsurgery. Nerve grafts were harvested at 9 months for immunohistochemical and morphological analyses. RESULTS: The decellularization protocol completely eliminated the cells while preserving the extracellular matrix of the nerve. No significant differences were observed in functional tests of locomotion and pain response. Reinnervation of the tibialis anterior muscles occurred in all animals, with some delay in the DCA group compared with the AG group. Histology showed a preserved fascicular structure in both AG and DCA; however, the number of axons distal to the nerve graft was higher in AG than in DCA. CONCLUSION: The decellularized graft assayed supported effective axonal regeneration when used to repair a 5-cm long gap in the sheep. As expected, a delay in functional recovery was observed compared with the AG because of the lack of Schwann cells.