Jiangtao Su

Dr. Jiangtao Su


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Xiwei HuangXiwei Huang
Xiwei Huang
UFUmar Farooq
Umar Farooq
JCJin Chen
Jin Chen
YGYakun Ge
Yakun Ge
HGHaijun Gao
Haijun Gao
JLJikui Luo
Jikui Luo
The future point-of-care diagnostics requires miniaturizing the existing bulky and expensive bioanalysis instruments, where lab-on-CMOS-chip-based technology can provide a promising solution. In this paper, we presented a surface acoustic wave (SAW) pumped lensless microfluidic imaging system for flowing cell detection and counting. Different from the previous lensless systems, which employ external bulky syringe pump for cell driven, the developed system directly integrates the SAW pump on the CMOS image sensor chip to drive the cell-containing microfluid. Moreover, an efficient temporal-differencing-based motion detection algorithm is proposed for continuous flowing cell detection and counting. Experimental results show that the SAW pump can drive the cells to flow at different driven powers, and also can keep the channel temperature below 40 °C so as not to harm the cells. The human bone marrow stromal cells flowing in the microfluidic channel can be automatically detected and counted with a low statistical error rate of −6.53%. The developed system thereby is competitive for point-of-care cell detection and counting application.

30 June 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
WSWen Sun
Wen Sun
JWJianhua Wang
Jianhua Wang
JCJin Chen
Jin Chen
Xiwei HuangXiwei Huang
Xiwei Huang
XRXin Rao
Xin Rao
LSLing-ling Sun
Ling-ling Sun
Cell dielectric property measurement holds significant potential for application in cell detection and diagnosis due to its label-free and noninvasive nature. In this study, we developed a biosensor designed to measure the permittivity of liquid samples, particularly cell suspensions at the nanoliter scale, utilizing microwave and millimeter wave coplanar waveguides in conjunction with a microchannel. This biosensor facilitates the measurement of scattering parameters within a frequency domain ranging from 1 GHz to 110 GHz. The obtained scattering parameters are then converted into dielectric constants using specific algorithms. A cell capture structure within the microchannel ensures that cell suspensions remain stable within the measurement zone. The feasibility of this biosensor was confirmed by comparison with a commercial Keysight probe. We measured the dielectric constants of three different cell suspensions (HepG2, A549, MCF-7) using our biosensor. We also counted the number of cells captured in multiple measurements for each cell type and compared the corresponding changes in permittivity. The results indicated that the real part of the permittivity of HepG2 cells is 0.2–0.8 lower than that of the other two cell types. The difference between A549 and MCF-7 was relatively minor, only 0.2–0.4. The fluctuations in the dielectric spectrum caused by changes in cell numbers during measurements were smaller than the differences observed between different cell types. Thus, the sensor is suitable for measuring cell suspensions and can be utilized for label-free, noninvasive studies in identifying biological cell suspensions.

27 January 2021 in Frontiers in Physics
Verified
Journal Article
Open access
PDF file
JSJiangtao Su
Jiangtao Su
JWJianhua Wang
Jianhua Wang
FWFei Wang
Fei Wang
LSLingling Sun
Lingling Sun
In this paper, the uncertainty and the impact of imperfect load calibration standard for on-wafer Through-Reflect-Match calibration method are analyzed with the help of 3D electromagnetic simulations. Based on the finding that load impedance can lead to significant errors in calibration, an automatic algorithm to determine the complex impedance of the load standard is proposed. This method evaluates the resistance as well as the parasitic inductance introduced by the misalignment of the probe tip to the substrate pad at mm-wave frequencies or the non-precize load standard. The proposed algorithm was verified by practical measurement, and the results show that by incorporating actual load impedance into the calibration algorithm, the deviations of RF measurement results are greatly suppressed.

25 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
HLHaode Li
Haode Li
JSJiangtao Su
Jiangtao Su
RWRuijin Wang
Ruijin Wang
ZLZhenyu Liu
Zhenyu Liu
MXMengmeng Xu
Mengmeng Xu
This review presents a concise overview of RF (radio frequency) power transistor behavior models, which is crucial for optimizing RF performance in high-frequency applications like wireless communication, radar, and satellites. The paper highlights the significance of accurate modeling in understanding transistor behavior and traces the evolution of behavior modeling techniques. Different behavior modeling strategies, such as LUT (look-up table) based models, polynomial equation-based models, and machine learning based models, are discussed along with their unique characteristics and modeling challenges. The review explores the difference between behavior models and the conventional empirical or physics-based modeling approaches, addressing the challenges of the accurate characterization of transistors at high frequencies and power levels. This paper concludes with an outlook of emerging trends, such as physical models combined with behavior models, shaping the future of RF power transistor modeling for more efficient communication systems.

24 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
CLCensong Liu
Censong Liu
JWJie Wang
Jie Wang
ZCZhanfei Chen
Zhanfei Chen
JLJun Liu
Jun Liu
JSJiangtao Su
Jiangtao Su
The aim of this paper is to model the effects of threading dislocations on both gate and drain currents of AlGaN/GaN high electron mobility transistors (HEMTs). The fraction of filled traps increases with the threading dislocations, while the trapping effects cause a decrease in drain current and an increase in gate leakage current. To model the drain current drop, the two simplified RC subcircuits with diodes are proposed to capture the charge trapping/detrapping characteristics. The trap voltages Vg_trap and Vd_trap generated by RC networks are fed back into the model to capture the effects of traps on drain current. Considering acceptor-decorated dislocations, we present a novel Poole–Frenkel (PF) model to precisely describe the reverse leakage gate current, which plays a dominant role in the gate leakage current. The proposed model, which uses physical parameters only, is implemented in Verilog-A. It is in excellent agreement with the experimental data.

25 April 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
XMXu Mengmeng
Xu Mengmeng
JSJiangtao Su
Jiangtao Su
RWRuijin Wang
Ruijin Wang
ZLZhongjie Lin
Zhongjie Lin
WXWeiyu Xie
Weiyu Xie
JLJun Liu
Jun Liu
Heterogeneous integration (HI) is a rapidly developing field aimed at achieving high-density integration and miniaturization of devices for complex practical radio frequency (RF) applications. In this study, we present the design and implementation of two 3 dB directional couplers utilizing the broadside-coupling mechanism and silicon-based integrated passive device (IPD) technology. The type A coupler incorporates a defect ground structure (DGS) to enhance coupling, while type B employs wiggly-coupled lines to improve directivity. Measurement results demonstrate that type A achieves <−16.16 dB isolation and <−22.32 dB return loss with a relative bandwidth of 60.96% in the 6.5–12.2 GHz range, while type B achieves <−21.21 dB isolation and <−23.95 dB return loss in the first band at 7–13 GHz, <−22.17 dB isolation and <−19.67 dB return loss in the second band at 28–32.5 GHz, and <−12.79 dB isolation and <−17.02 dB return loss in the third band at 49.5–54.5 GHz. The proposed couplers are well suited for low cost, high performance system-on-package radio frequency front-end circuits in wireless communication systems.