Vanesa Fernandez-Cavero

Dr. Vanesa Fernandez-Cavero

Universidad de Valladolid, Valladolid, Castille-Leon, Spain
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
Tomas Garcia-CalvaTomas Garcia-Calva
Tomas Garcia-Calva
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
VFVanesa Fernandez-Cavero
Vanesa Fernandez-Cavero
Rene Romero-TroncosoRene Romero-Troncoso
Rene Romero-Troncoso
There is an increasing interest in improving energy efficiency and reducing operational costs of induction motors in the industry. These costs can be significantly reduced, and the efficiency of the motor can be improved if the condition of the machine is monitored regularly and if monitoring techniques are able to detect failures at an incipient stage. An early fault detection makes the elimination of costly standstills, unscheduled downtime, unplanned breakdowns, and industrial injuries possible. Furthermore, maintaining a proper motor operation by reducing incipient failures can reduce motor losses and extend its operating life. There are many review papers in which analyses of fault detection techniques in induction motors can be found. However, all these reviewed techniques can detect failures only at developed or advanced stages. To our knowledge, no review exists that assesses works able to detect failures at incipient stages. This paper presents a review of techniques and methodologies that can detect faults at early stages. The review presents an analysis of the existing techniques focusing on the following principal motor components: stator, rotor, and rolling bearings. For steady-state and transient operating modes of the motor, the methodologies are discussed and recommendations for future research in this area are also presented.

9 May 2017 in IEEE Access
Verified
Journal Article
Open access
VFVanesa Fernandez-Cavero
Vanesa Fernandez-Cavero
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
ODOscar Duque-Perez
Oscar Duque-Perez
JPJoan Pons-Llinares
Joan Pons-Llinares
Fault detection in induction motors operating in non-stationary regimes has become a need in today's industry. Most of the works published deal with line-fed motors. Nevertheless, the number of inverter-fed induction motors has significantly increased in recent years. Therefore, several fault detection techniques have been proposed lately for this type of motors, based mainly on an adequate input signal processing to obtain fault signatures in the time-frequency domain. In this paper, a comparison of time-frequency techniques applied to fault detection in inverter-fed induction motors in a transient state is presented. For that purpose, the techniques are applied to two current signals acquired from two induction motors with two types of faults: bar breakage and mixed eccentricity. The paper shows the particularities and special difficulties of diagnosing under this type of feeding, reviewing the works related to each technique. The strengths and weaknesses of these techniques are discussed with the goal of providing a criterion for its application in an industrial environment and guidance for future developments in this field.

17 March 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
VFVanesa Fernandez-Cavero
Vanesa Fernandez-Cavero
JPJoan Pons-Llinares
Joan Pons-Llinares
Oscar Duque-PerezOscar Duque-Perez
Oscar Duque-Perez
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
Fault detection in induction motors powered by inverters operating in non-stationary regimes remains a challenge. The trajectory in the time-frequency plane of harmonics related to broken rotor bar develops very in proximity to the path described by the fundamental component. In addition, their energy is much lower than the amplitude of the first harmonic. These two characteristics make it challenging to observe them. The Dragon Transform (DT), here presented, is developed to overcome the described problem. In this paper, the DT is assessed with non-linear inverter-fed startups, where its high time and frequency resolutions facilitate the monitoring of fault harmonics even with highly adjacent trajectories to the first harmonic path.

8 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Tomas Garcia-CalvaTomas Garcia-Calva
Tomas Garcia-Calva
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
VFVanesa Fernandez-Cavero
Vanesa Fernandez-Cavero
AGARTURO GARCIA-PEREZ
ARTURO GARCIA-PEREZ
Rene Romero-TroncosoRene Romero-Troncoso
Rene Romero-Troncoso
The fault diagnosis of electrical machines during startup transients has received increasing attention regarding the possibility of detecting faults early. Induction motors are no exception, and motor current signature analysis has become one of the most popular techniques for determining the condition of various motor components. However, in the case of inverter powered systems, the condition of a motor is difficult to determine from the stator current because fault signatures could overlap with other signatures produced by the inverter, low-slip operation, load oscillations, and other non-stationary conditions. This paper presents a speed signature analysis methodology for a reliable broken rotor bar diagnosis in inverter-fed induction motors. The proposed fault detection is based on tracking the speed fault signature in the time-frequency domain. As a result, different fault severity levels and load oscillations can be identified. The promising results show that this technique can be a good complement to the classic analysis of current signature analysis and reveals a high potential to overcome some of its drawbacks.

1 March 2021 in ISA Transactions
Verified
Journal Article
Closed access
VFVanesa Fernandez-Cavero
Vanesa Fernandez-Cavero
JPJoan Pons-Llinares
Joan Pons-Llinares
Oscar Duque-PerezOscar Duque-Perez
Oscar Duque-Perez
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO

22 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VFVanesa Fernandez-Cavero
Vanesa Fernandez-Cavero
LGLuis Angel Garcia-Escudero
Luis Angel Garcia-Escudero
JPJoan Pons-Llinares
Joan Pons-Llinares
MFMiguel Fernández
Miguel Fernández
Oscar Duque-PerezOscar Duque-Perez
Oscar Duque-Perez
DANIEL MORINIGO-SOTELODANIEL MORINIGO-SOTELO
DANIEL MORINIGO-SOTELO
A proper diagnosis of the state of an induction motor is of great interest to industry given the great importance of the extended use of this motor. Presently, the use of this motor driven by a frequency converter is very widespread. However, operation by means of an inverter introduces certain difficulties for a correct diagnosis, which results in a signal with higher harmonic content and noise level, which makes it difficult to perform a correct diagnosis. To solve these problems, this article proposes the use of a time-frequency technique known as Dragon Transform together with the functional ANOVA statistical technique to carry out a proper diagnosis of the state of the motor by working directly with the curves obtained from the application of the transform. A case study is presented showing the good results obtained by applying the methodology in which the state of the rotor bars of an inverter-fed motor is diagnosed considering three failure states and operating at different load levels.