Matthias Koegl

Matthias Koegl


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2024 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
NMNikita Mil‘to
Nikita Mil‘to
LZLars Zigan
Lars Zigan
The study investigates a jet impingement cooling process of a cylindrical geometry relevant for electric and electronic applications. The applied two-color detection technique enables a simultaneous determination of film temperature and film thickness. For this purpose, the heat transfer oil Marlotherm LH was doped with the temperature-sensitive fluorescence tracer nile red. The temperature determination was realized by suitable band pass filters. Preliminary spectral investigations were carried out in terms of varying dye concentration, temperature and film thickness. At high dye concentrations (up to 37.5 mg/L), reabsorption effects lead to a spectral shift toward higher wavelengths with increasing film thickness. Low dye concentrations (0.29 mg/L, 0.59 mg/L) show no film thickness dependent spectral shift. A film temperature investigation at low dye concentration showed no bias of the intensity ratio due to film thickness, i.e., no additional spectral shift toward lower wavelengths was observed. The investigations on the jet impingement setup revealed an increasing film temperature and decreasing film thickness with increasing solid temperature. The average film temperature increases with increasing solid temperature from 298 (solid temperature 298 K) to 308 K (solid temperature 398 K). At higher solid temperatures, the film temperature increases with distance to the stagnation zone. The average film thickness decreases with increasing solid temperature from 0.24 to 0.17 mm. At high solid temperatures, the film temperature increased with radial distance to the stagnation zone. This behavior is caused by the increasing temperature gradient with increasing solid temperature and decreasing viscosity with increasing film temperature.

17 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
MDMoritz Delwig
Moritz Delwig
LZLars Zigan
Lars Zigan
This study investigated a novel two-color LIF (laser-induced fluorescence) technique for thermometry in coolants relevant for electric components. In principle, this diagnostic enables thermometry in liquid flows but also a simultaneous determination of film thickness and film temperature, which is relevant, e.g., for jet impingement cooled electric components. Temperature measurements are based on a temperature-sensitive intensity ratio of special tracers realized by suitable band pass filters within the respective emission spectra. For this purpose, the heat transfer fluids Fragoltherm F12, Marlotherm LH, and a water–glycol mixture WG20 (80 vol.% water, 20 vol.% glycol) and its individual components were doped with suitable tracers. The tracer Eosin-Y was utilized for polar coolants (water, WG20, and glycol) and Nile red was utilized for non-polar solvents (Fragoltherm F12 and Marlotherm LH). The spectral LIF intensities were recorded for a wide range of temperatures (253–393 K), which are relevant for cooling of electric motors, batteries, and power electronics. Furthermore, absorption spectra were analyzed as well. The temperature-dependent fluorescence measurements revealed different behavior for the polar and non-polar solvents. A temperature increase in the polar solvents (water, WG20, glycol) led to a spectral shift of the emission peaks of Eosin-Y towards longer wavelengths (red-shifted), while the peaks of Nile red in the non-polar solvents (Fragoltherm F12 and Marlotherm LH) showed an opposite behavior and were blue-shifted. The highest average temperature sensitivity was achieved for Marlotherm LH (4.22%/K), followed by glycol (1.99%/K), WG20 (1.80%/K), water (1.62%/K), and Fragoltherm F12 (1.12%/K). These sensitivities are similar to or even much higher than the literature data of other LIF tracers, which were, however, not determined in those coolants. Consequently, the two novel proposed dyes for the studied heat transfer liquids enable a reliable temperature determination.

23 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
JVJonas Vogler
Jonas Vogler
LZLars Zigan
Lars Zigan
This study investigated spectral laser-induced fluorescence signals of dyes in fuels for automotive and aerospace applications under low temperatures and cryogenic conditions down to 183 K. For this purpose, a fluorescence chamber was developed based on cooling with liquid nitrogen. The design enabled a minimal inner chamber temperature of 153 K. Furthermore, the applicability of two-color LIF for liquid thermometry was evaluated under these conditions. The temperature determination was based on the temperature-sensitive fluorescence intensity ratio of the special dyes doped into the fuels determined in suitable spectral regions, which represented common bandpass filters. For this purpose, the fluorescence signals of the dye doped into the gasoline and jet fuel surrogate isooctane were tested as well as blends of isooctane and the ethanol biofuels E20 (comprising 80 vol.% isooctane and 20 vol.% ethanol), E40, and E100. Additionally, a realistic multi-component fuel Jet A-1 mixed with a suitable fluorescence dye was investigated. E100 was doped with Eosin-Y, and the remaining fuels were doped with Nile red. Temperature-dependent spectral LIF intensities were recorded in the range of 183 K–293 K, which simulate extreme environments for aerospace and automotive applications. Frozen fuel–dye mixtures cause significant extinction effects and prevent sufficient signal detection at low and cryogenic temperatures, defining the detection limit. A temperature decrease led to a spectral shift in the emission peaks of E100 doped with Eosin-Y toward shorter wavelengths, while the spectra of mixtures doped with Nile red were shifted toward longer wavelengths. The suggested bandpass filters produced the temperature-sensitive intensity ratio (the average over the temperature interval) of the dyes with the largest sensitivity for Jet A-1 (5.2%/K), followed by E100 (4.95%/K), E40 (4.07%/K), E20 (3.23%/K), and isooctane (3.07%/K), even at cryogenic temperatures.

14 February 2025 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
LBLeon Breitenbach
Leon Breitenbach
The study investigates the liquid film thickness-dependent laser-induced fluorescence of a dye in a heat transfer oil affected by wall reflections at different solid surface materials (aluminum, copper, steel) and surface textures (polished and sandblasted). A specially designed fluorescence cell allows a precise adjustment of the film thickness at a fixed temperature and allows the investigation of various substrate materials and textures. Photo-dissociation free measurements are ensured due to a closed-loop circuit, driven by a pump. The LIF signal was generated by admixture of the fluorescent dye Nile red to the heat transfer oil Marlotherm LH. A CW laser at 532 nm was applied for excitation, and emissions were recorded by using a spectrometer. The use of a relatively low dye concentration (0.59 mg/l) ensures negligible reabsorption of the fluorescence and thus minimal spectral changes due to a variation in film thickness, which is indispensable for precise temperature measurements. A comparison of the dye fluorescence affected by reflections at different solid materials and surface treatments for a 1-mm film thickness reveals a similar trend for all investigated materials, except for copper. Copper leads to a surface texture-dependent spectral shift of the peak emission (polished: 3.8 nm, sandblasted: 4.3 nm) toward larger wavelengths in comparison with the remaining materials (peak always at 586.4 nm). This is attributed to the more distinct wavelength-dependent reflection behavior of copper evaluated in a theoretical study. Since the fluorescence signal experiences a stronger reflection in comparison with the incident laser beam, this leads to a spectral shift of the emission spectra toward larger wavelengths. A model approach is developed describing effects of direct and non-direct reflection of fluorescence for different materials and textures. A diffusive reflection leads to an overall decrease of reabsorption. This is caused by the reduced direct reflection of laser light, which passes through the liquid film a second time (or multiple times) and consequently less emission signal. Temperature-dependent measurements in combination with a two-color measurement approach showed the significant influence of wavelength-dependent reflection behavior on the temperature determination on liquid films.

22 February 2024 in Measurement Science and Technology
Verified
Journal Article
Closed access
MKMatthias Koegl
Matthias Koegl
JGJake Glahn
Jake Glahn
LZLars Zigan
Lars Zigan
This study investigates a two-colour laser-induced fluorescence (LIF) technique for thermometry in cooling lubricants (CL) for machining. The diagnostic technique should enable a simultaneous determination of cooling film thickness and film temperature, which is relevant for typical machining processes like turning and milling processes. The temperature determination is based on a temperature-sensitive fluorescence intensity ratio of a special dye determined in suitable spectral regions representing common band pass filters. For this purpose, two CL emulsions CL6 (6 vol.% CL, 94 vol.% water; normal machining) and CL10 (10 vol.% CL, 90 vol.% water; heavy machining) and its individual components were doped with the fluorescence dye Eosin-Y. Temperature dependent spectral LIF intensities were recorded in the range of 273–313 K, which are relevant for milling and cutting operations. Furthermore, absorption spectra were analysed as well. The temperature-dependent fluorescence measurements revealed a temperature limit for the emulsion stability. The emission peaks of Eosin-Y are shifted with increasing temperature towards longer wavelengths. The sensitivities of CL10 (1.88%/K) and CL6 (1.58%/K) are comparable to or even higher than the sensitivities of other LIF dyes provided in the literature. The literature-based dyes were however not determined in those CL. The measurements showed, that the investigated tracer-CL/water emulsions mixed with the dye enable a reliable temperature determination.

4 October 2025 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
MKMatthias Koegl
Matthias Koegl
JVJonas Vogler
Jonas Vogler
LBLeon Breitenbach
Leon Breitenbach
LZLars Zigan
Lars Zigan
The present study focuses on the thermal characterization of a Rayleigh–Bénard (R–B) convection (Rayleigh number Ra = 2.20⋅107 and Prandtl number Pr = 29.9) in the synthetic heat transfer oil Marlotherm LH (benzyltoluene) with a two-color laser-induced fluorescence measurement technique (2c-LIF). For this purpose, a compact convection chamber with unity aspect ratio was developed, which enables extreme temperature differences up to 120 K. The fluorescence signal is generated by doping the heat transfer oil with the fluorophore Nile red and its excitation by a pulsed Nd:YAG laser at 532 nm. First, the 2c-LIF technique is calibrated under homogeneous temperature conditions in the cell. Here, the relative thermal sensitivity decreases with increasing liquid temperatures. Second, the detachment and rise or fall of multiple thermal plumes in the R–B cell is analyzed, while the bottom wall was heated to 360 K, and the top wall was cooled to 240 K, resulting in a respective temperature field of the mixture in the range of 300–345 K. The time-resolved LIF measurements enable a characterization of the buoyancy-driven flow in terms of temperature field, heat flux density, thermal plume shape and plume velocity. The local heat flux density (11.5 kW/m2), heat transfer coefficient (311 W/m2⋅K) and Nusselt number (36.4) of the cold boundary were determined from the temperature profile. The highest plume velocities are in the range of 15 mm/s at the studied condition with large temperature stratification. No stationary large recirculation zones were detected in the cell, which are typical for such thermal R–B convection conditions.