Background: The stability index estimation algorithm was derived and applied to develop and implement a balance ability diagnosis system that can be used in daily life. Methods: The system integrated an approach based on sensory function interaction, called the clinical test of sensory interaction with balance. A capacitance and resistance sensing type force mat was fabricated, and a stability index prediction algorithm was developed and applied using the center of pressure variables. The stability index prediction algorithm derived a center of pressure variable for 103 elderly people by Nintendo Wii Balance Board to predict the stability index of the balance system (Biodex SD), and the accuracy of this approach was confirmed. Results: As a result of testing with the test set, the linear regression model confirmed that the r-value ranged between 0.943 and 0.983. To confirm the similarity between the WBB and the flexible force mat, each measured center of pressure value was inputted and calculated in the developed regression model, and the result of the correlation coefficient validation confirmed an r-value of 0.96. Conclusion: The system developed in this study will be applicable to daily life in the home in the form of a floor mat.
The Wii balance board (WBB) is a simplified force plate system used to evaluate the balancing ability of the elderly via a sensory interaction task to confirm a significant standing balance index. The accuracy of this system has been verified in previous studies. In this study, an instrumented and modified clinical test of sensory interaction on balance (i-mCTSIB) was performed on 84 elderly subjects, and the variables for center of pressure (CoP) were calculated using WBB for each task condition. The results indicate that the visual condition has a significant effect on the sway proprioceptive sensory variables with a foam condition as their complexity increases. In addition, the correlation between the variable and Berg Balance Scale was not confirmed since CTSIB is a sensory interaction on balance ability. Therefore, WBB can be used to evaluate balancing ability based on sensory interactions consisting of the surface condition.
Background: The Stability Index estimation algorithm was derived and applied to develop and implement a balance ability diagnosis system that can be used at daily life. Methods: The system integrated an approach based on sensory function interaction, called the clinical test of sensory interaction with balance (CTSIB). The piezo-resistive force mat was fabricated, and a Stability Index prediction algorithm was developed and applied using the center of pressure (CoP) variables. The Stability Index prediction algorithm derived a CoP variable for 103 elderly people by Nintendo Wii Balance Board (WBB) to predict the Stability Index of the Balance System (Biodex SD). And, the accuracy was confirmed through the correlation between the real and predicted value. Results: As a result of testing with the test-set, the linear regression model confirmed that the r value ranged between 0.943 to 0.983. To confirm the similarity between the WBB and flexible force mat, each measured CoP value was input and calculated into the developed regression model, and the result of the correlation coefficient validation confirmed an r value of 0.96. Conclusion: The system developed in this study will be applicable to the daily life of the home in the form of a floor mat.