Ogan Karabas

Mr. Ogan Karabas

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
OKOgan Karabas
Ogan Karabas
MÖMurat Can Önen
Murat Can Önen
KYKadri Süleyman Yiğit
Kadri Süleyman Yiğit
In a modern-day household, the most significant part of energy consumption is space heating. In this study, the effects of connection configurations on the heat transfer from the radiator are investigated. The difference between the current study and previous studies is that all possible valve connection configurations are investigated on the radiator, instead of only having water enter through one valve and outlet through another. The experimental results of heat transfer from the radiator in all connection configurations are presented. In addition, the temperature distributions on the radiator surface for each connection configuration are visualized using a thermal camera, and remarkable findings are presented. These images provide insights into the water flow distribution in the ducts of the radiator and the effects of the distribution on heat transfer. CFD simulations were conducted to analyze temperature and flow distributions for different connection configurations and revealed that two inlets from the bottom and two outlets from the top of the panel radiator have the best case in terms of temperature distribution. This study contributes to improving energy consumption efficiency for space heating by determining the heat transfer rate from the radiator in different valve connection configurations.

10 May 2024 in Research Square
Verified
Preprint
Open access
PDF file
TCTimur Canel
Timur Canel
IBIrem Baglan
Irem Baglan
OKOgan Karabas
Ogan Karabas
Mathematical modeling of micro-scale grooves was made on the polycarbonate plate. The micro-scale groove's surface and cross-section structure, created by scanning at a constant speed using a 30 W beam with a CO2 laser, was examined with a high-resolution optical microscope and the groove geometry was precisely measured. Using the data obtained from the measurements and the physical constants of the polycarbonate, mathematical modeling was made for the temperature distribution in two different directions. The Fourier Finite difference method was used to model the temperature distribution along the line on the polycarbonate surface. The experimental studies with 5 different laser beam powers were carried out again to prove the accuracy and validity of the model. Lateral temperature distribution on the surface of the material and vertical temperature distribution towards the depths of the material were investigated separately. The error rates between the proposed mathematical model and the experimental results are between 3.24 % and 8.44 %. Since the experimental results are in good agreement with the proposed model, it can be said that the proposed mathematical model is a reliable model. Moreover, the temperature distributions both in the lateral direction and vertically into the material were modeled with CFD-Computational Fluid Dynamics. The sources of the differences between the ignition, melting and glass transition temperature obtained from the CFD analysis and the actual temperature values were discussed.

24 April 2025 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Open access
PDF file
TCTimur Canel
Timur Canel
IBIrem Baglan
Irem Baglan
OKOgan Karabas
Ogan Karabas
The primary goal of this study is to present a mathematical model that forecasts the quality of the final product to be obtained in laser material processing. Two stages of testing have been conducted to assess the dependability of the proposed mathematical model: an experimental phase and a CFD analytical phase. Heat dispersion mechanisms on and within the material are the foundation for the suggested mathematical model. A CO2 laser was used to create micro-grooves in the polycarbonate sheet. Top and cross-sectional images of the laser-created grooves were taken using a high-resolution optical microscope. The groove geometry was measured from the images obtained. The dimensions of the ablation, melting, and glass transition zones obtained from the measurements and the thermal constants of the material were used in the mathematical modeling. The Fourier finite difference method was used to model the temperature distribution along the line on the polycarbonate surface. The lateral temperature distribution on the surface of the material and the vertical temperature distribution towards the depth of the material were studied separately. The error rates between the proposed mathematical model and the experimental results are between 3.24 and 8.44%. Since the experimental results are in good agreement with the proposed model, it can be said that the proposed mathematical model is reliable. In addition, the temperature distributions both in the lateral direction and perpendicular to the material were modeled using CFD (Computational Fluid Dynamics). The sources of the differences between the ignition, melting, and glass transition temperatures obtained from the CFD analysis and the real temperature values were discussed.

27 July 2026 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
AKAli Kibar
Ali Kibar
OKOgan Karabas
Ogan Karabas
MBMehmet Bayraktutar
Mehmet Bayraktutar
Serkan SezenSerkan Sezen
Serkan Sezen
EÖEngin Özdemir
Engin Özdemir
KYKadri Süleyman Yiğit
Kadri Süleyman Yiğit
Fixed-tilt photovoltaic (PV) systems suffer from cosine losses, especially at low solar angles during morning and evening, because they cannot track the Sun’s daily and seasonal motion. This leads to optical misalignment and reduced efficiency in mid-latitude regions such as Türkiye. Although single-axis tracking systems address this issue, field-validated data on their year-long performance under real industrial conditions remain limited. This study presents a 1-year experimental comparison between fixed-tilt and single-axis tracking PV systems operating in Kocaeli, Türkiye (40°49′20.61″ N, 29°55′23.98″ E). Two identical 2.7 kWp grid-tied arrays were monitored at 5-min intervals from September 2024 to August 2025. The single-axis tracker employed an astronomical, time-based control algorithm to maintain favorable panel orientation throughout the day. The results show an annual energy gain of 28.7%, with monthly improvements reaching 38% during the summer. Winter performance was more site- and condition-dependent: under typical snow-free conditions, the realized gain was lower than in summer and strongly influenced by the direct-to-diffuse irradiance balance. In addition, a snow-shedding event highlighted an operational advantage of the tracker under specific winter conditions, but this event should not be interpreted as a universally representative winter-gain benchmark. From an economic perspective, the tracking system achieved a 12.2% lower Levelized Cost of Energy ($ 0.036/kWh) and a shorter payback period (2.25 years) than that of the fixed-tilt system (2.65 years). Therefore, these findings demonstrate the practical benefit of single-axis tracking under the current industrial rooftop conditions; however, the magnitude of the benefit depends on local climate, inverter sizing, snow behavior, and installation alignment.

30 June 2024 in Hittite Journal of Science and Engineering
Verified
Journal Article
Open access
PDF file
HCHalid Ceylan
Halid Ceylan
OKOgan Karabas
Ogan Karabas
KYKadri Süleyman Yiğit
Kadri Süleyman Yiğit
In this study, drop form flow examinations, which form the basis of IV applications used for therapeutic purposes, were performed. Fluid Intravenous (IV) is the practice of administering fluids into a vein. In IV applications, flow must be monitored in order to follow and control the treatment process. For this purpose, the fluid can be converted into drop form with a simple mechanism and the flow rate and volume data can be calculated by the drop counting method. Examining drop form flow processes and analyzing microdrops correctly increases the accuracy in calculating flow data and, most importantly, increases the quality of treatment in IV applications. In the scope of this study, the formation processes of microdrops and the affecting parameters were analyzed. Along with microdrop analysis, error evaluation of the drop counting method and evaluation of measurement techniques were carried out to ensure a healthy and accurate measurement process. System tests and verification were carried out with optical systems, one of the measurement techniques. As a result, this study was carried out on the importance of monitoring systems and measurement parameters in IV applications.