Interrupting the transmission of airborne (<≈5 µm) respiratory pathogens indoors is not a new challenge, but it has attracted unprecedented interest due to the COVID-19 pandemic during 2020–2021. However, bacterial respiratory pathogens with known or potential airborne transmission account for an appreciable proportion of the communicable disease burden globally. We aimed to systematically review quantitative, laboratory-based studies of air disinfection techniques for airborne respiratory bacteria. Three databases (PubMed, Web of Science, Scopus) were searched, following PRISMA guidelines. A total of 9596 articles were identified, of which 517 were assessed in detail and of which 26 met the inclusion and quality assessment criteria. Seven air disinfection techniques, including UV-C light, filtration, and face masks, among others, were applied to 13 different bacterial pathogens. More than 80% of studies suggested that air disinfection techniques were more effective at inactivating or killing bacteria than the comparator or baseline condition. However, it was not possible to compare these techniques because of methodological heterogeneity and the relatively small number of the studies. Laboratory studies are useful for demonstrating proof-of-concept and performance under controlled conditions. However, the generalisability of their findings to person-to-person transmission in real-world settings is unclear for most of the pathogens and techniques we assessed.
Pseudomonas aeruginosa (Pa) is the predominant bacterial pathogen in people with cystic fibrosis (CF) and can be transmitted by airborne droplet nuclei. Little is known about the ability of ultraviolet band C (UV-C) irradiation to inactivate Pa at doses and conditions relevant to implementation in indoor clinical settings. We assessed the effectiveness of UV-C (265 nm) at up to seven doses on the decay of nebulized Pa aerosols (clonal Pa strain) under a range of experimental conditions. Experiments were done in a 400 L rotating sampling drum. A six-stage Andersen cascade impactor was used to collect aerosols inside the drum and the particle size distribution was characterized by an optical particle counter. UV-C effectiveness was characterized relative to control tests (no UV-C) of the natural decay of Pa. We performed 112 tests in total across all experimental conditions. The addition of UV-C significantly increased the inactivation of Pa compared with natural decay alone at all but one of the UV-C doses assessed. UV-C doses from 246–1968 µW s/cm2 had an estimated effectiveness of approximately 50–90% for airborne Pa. The effectiveness of doses ≥984 µW s/cm2 were not significantly different from each other (p-values: 0.365 to ~1), consistent with a flattening of effectiveness at higher doses. Modelling showed that delivering the highest dose associated with significant improvement in effectiveness (984 µW s/cm2) to the upper air of three clinical rooms would lead to lower room doses from 37–49% of the 8 h occupational limit. Our results suggest that UV-C can expedite the inactivation of nebulized airborne Pa under controlled conditions, at levels that can be delivered safely in occupied settings. These findings need corroboration, but UV-C may have potential applications in locations where people with CF congregate, coupled with other indoor and administrative infection control measures.