Bernhard Frerich

Prof. Dr. Bernhard Frerich


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AKAnnika Kasten
Annika Kasten
CGCordula Grüttner
Cordula Grüttner
JKJens-Peter Kühn
Jens-Peter Kühn
RBRainer Bader
Rainer Bader
JPJuliane Pasold
Juliane Pasold
BFBernhard Frerich
Bernhard Frerich
Magnetic resonance imaging (MRI) using measurement of the transverse relaxation time (R2*) is to be considered as a promising approach for cell tracking experiments to evaluate the fate of transplanted progenitor cells and develop successful cell therapies for tissue engineering. While the relationship between core composition of nanoparticles and their MRI properties is well studied, little is known about possible effects on progenitor cells. This in vitro study aims at comparing two magnetic iron oxide nanoparticle types, single vs. multi-core nanoparticles, regarding their physico-chemical characteristics, effects on cellular behavior of adipose tissue-derived stem cells (ASC) like differentiation and proliferation as well as their detection and quantification by means of MRI. Quantification of both nanoparticle types revealed a linear correlation between labeling concentration and R2* values. However, according to core composition, different levels of labeling concentrations were needed to achieve comparable R2* values. Cell viability was not altered for all labeling concentrations, whereas the proliferation rate increased with increasing labeling concentrations. Likewise, deposition of lipid droplets as well as matrix calcification revealed to be highly dose-dependent particularly regarding multi-core nanoparticle-labeled cells. Synthesis of cartilage matrix proteins and mRNA expression of collagen type II was also highly dependent on nanoparticle labeling. In general, the differentiation potential was decreased with increasing labeling concentrations. This in vitro study provides the proof of principle for further in vivo tracking experiments of progenitor cells using nanoparticles with different core compositions but also provides striking evidence that combined testing of biological and MRI properties is advisable as improved MRI properties of multi-core nanoparticles may result in altered cell functions.

3 June 2015 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
MDMichael Dau
Michael Dau
PKPeer Kämmerer
Peer Kämmerer
KHKai‐Olaf Henkel
Kai‐Olaf Henkel
TGThomas Gerber
Thomas Gerber
BFBernhard Frerich
Bernhard Frerich
KGKarsten K. H. Gundlach
Karsten K. H. Gundlach

1 March 2018 in Microvascular Research
Verified
Journal Article
Closed access
EGEberhard Grambow
Eberhard Grambow
MDMichael Dau
Michael Dau
AHAmadeus Holmer
Amadeus Holmer
VLVicky Lipp
Vicky Lipp
BFBernhard Frerich
Bernhard Frerich
PKPeer Wolfgang Kämmerer
Peer Wolfgang Kämmerer

16 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
TFThomas Frankenberger
Thomas Frankenberger
CGConstantin Leon Graw
Constantin Leon Graw
Nadja EngelNadja Engel
Nadja Engel
TGThomas Gerber
Thomas Gerber
BFBernhard Frerich
Bernhard Frerich
MDMichael Dau
Michael Dau
Polyetheretherketone (PEEK) has the potential to overcome some of the disadvantages of titanium interbody implants in anterior cervical and discectomy and fusion (ACDF). However, PEEK shows an inferior biological behavior regarding osseointegration and bioactivity. Therefore, the aim of the study was to create a bioactive surface coating on PEEK implants with a unique nanopore structure enabling the generation of a long-lasting interfacial composite layer between coating material and implant. Seventy-two PEEK implants—each thirty-six pure PEEK implants (PI) and thirty-six PEEK implants with a sprayed coating consisting of nanocrystalline hydroxyapatite (ncHA) embedded in a silica matrix and interfacial composite layer (SPI)—were inserted in the femoral condyles of adult rats using a split-side model. After 2, 4 and 8 weeks, the femur bones were harvested. Half of the femur bones were used in histological and histomorphometrical analyses. Additionally, pull-out tests were performed in the second half. Postoperative healing was uneventful for all animals, and no postoperative complications were observed. Considerable crestal and medullary bone remodeling could be found around all implants, with faster bone formation around the SPI and fewer regions with fibrous tissue barriers between implant and bone. Histomorphometrical analyses showed a higher bone to implant contact (BIC) in SPI after 4 and 8 weeks (p < 0.05). Pull-out tests revealed higher pull-out forces in SPI at all time points (p < 0.01). The presented findings demonstrate that a combination of a bioactive coating and the permanent chemical and structural modified interfacial composite layer can improve bone formation at the implant surface by creating a sustainable bone-implant interface. This might be a promising way to overcome the bioinert surface property of PEEK-based implants.

25 October 2011 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
BFBernhard Frerich
Bernhard Frerich
KWKarsten Winter
Karsten Winter
KSKonstanze Scheller
Konstanze Scheller
UBUlf‐Dietrich Braumann
Ulf‐Dietrich Braumann

15 November 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NENadja Engel
Nadja Engel
CFCarsten Fechner
Carsten Fechner
AVAnnika Voges
Annika Voges
RORobert Ott
Robert Ott
JSJan Stenzel
Jan Stenzel
BFBernhard Frerich
Bernhard Frerich
A clinical implementation of cell-based bone regeneration in combination with scaffold materials requires the development of efficient, controlled and reproducible seeding procedures and a tailor-made bioreactor design. A perfusion system for efficient, homogeneous, and rapid seeding with human adipogenic stem cells in bone substitute scaffolds was designed. Variants concerning medium inlet and outlet port geometry, i.e. cylindrical or conical diffuser, cell concentration, perfusion mode and perfusion rates were simulated in silico. Cell distribution during perfusion was monitored by dynamic [18F]FDG micro-PET/CT and validated by laser scanning microscopy with three-dimensional image reconstruction. By iterative feedback of the in silico and in vitro experiments, the homogeneity of cell distribution throughout the scaffold was optimized with adjustment of flow rates, cell density and perfusion properties. Finally, a bioreactor with a conical diffusor geometry was developed, that allows a homogeneous cell seeding (hoover coefficient: 0.24) in less than 60 min with an oscillating perfusion mode. During this short period of time, the cells initially adhere within the entire scaffold and stay viable. After two weeks, the formation of several cell layers was observed, which was associated with an osteogenic differentiation process. This newly designed bioreactor may be considered as a prototype for chairside application.