A high-sensitivity salinity sensor based on a free space propagation-core mode Mach–Zehnder interferometer was proposed with a well-designed exposed-core microstructured optical fiber. The real-time salinity sensing was achieved by using an exposed-core microstructured optical fiber shortened to 228 µ m. The proposed sensor has a salinity measurement range from 0 ‰ to 40 ‰ and a salinity sensitivity of around −2.29 nm/‰, corresponding to a refractive index sensitivity of −13 103.16 nm/RIU. The measurement error caused by the temperature is only 0.02 ‰ °C −1 , which can be neglected in practical applications. This kind of sensor also presents a Fabry-Perot interference phenomenon besides the Mach–Zehnder interferometer, which shows a flexible sensing structure. The proposed sensor offers an alternative method for accurate measurement of seawater salinity.
A high-resolution salinity sensor based on a self-referenced parallel Fabry–Perot fiber microcavity is proposed. The sensor is fabricated by inserting a short piece of exposed-core microstructure fiber (ECF) between multimode fiber (MMF) and single-mode fiber (SMF). Due to the unique exposed-core fiber structure and the specially designed SMF-MMF-ECF-SMF structure, two prominent parallel Fabry–Perot interferometers (FPIs) are constructed. Besides, a self-referenced differential phase-demodulation technology is proposed to eliminate the wavelength uncertainty of the spectra measurement devices. Enhanced demodulation system stability and accuracy are achieved by analyzing the phase shift responses of the reflection spectrum. A high salinity-phase sensitivity of 17.36 deg/ ‰ in the range from 0 ‰ to 35 ‰ is obtained, and the corresponding refractive index (RI) sensitivity is ${1.04} \times {10} ^{{5}}$ deg/RIU. The salinity resolution and RI resolution are as low as 0.0058 ‰ and ${9.6} \times {10} ^{-{7}}$ RIU, respectively, which gives a great potential for harsh environmental monitoring and label-free biochemical analysis.
In this paper, a simplified hollow-core photonic crystal fiber surface-enhanced Raman scattering (SERS) probe is presented. Silver nanoprisms are grown with a photoreduction method and account for the SERS, which have better electromagnetic enhancement than spherical silver nanoparticles at 785 nm. Due to the antiresonant reflecting guidance mechanism, the excited laser and SERS signal are effectively guided in such a fully filled hollow-core photonic crystal fiber SERS probe and complicated selective filling with target sample is avoided. Rhodamine 6G molecules are used as probe molecules and the simplified hollow-core photonic crystal fiber SERS probe is test. Detection of low concentration Rhodamine 6G down to 10−8 M is achieved with a short integration time of 300 ms.
In this paper, we demonstrate a phase-demodulated high-order intermodal interference based on exposed-core microstructure fiber (ECF), and it is applied for low concentration in-situ deafness gene DNA detection. The simulation results show that the phase sensitivity of the high-order interference mode (LP 01 -LP 21a ) is about 6 times higher than that of the low-order (LP 01 -LP 11b ), which is different from the traditional wavelength coded demodulation method. Hybridization experiments of complementary and non-complementary deafness gene DNA fragments were carried out, and the sensing system was obtained to screen for complementary gene fragments. DNA complementary fragments with concentrations as low as 1 nM can be detected with a corresponding phase variation of 7.32 °. The limit of detection is as low as 0.089 nM. The experiment and theoretical analysis prove that this fiber optic biosensor can obtain high sensitivity and signal-to-noise ratio with phase-demodulation high-order intermodal interference scheme, which provides an alternative for the subsequent studies of high sensitivity and high precision sensors.
14 July 2022 in Journal of Physics D: Applied Physics
This study proposes a high-resolution optical fiber Fabry–Perot (FP) temperature sensor and it is based on an exposed-core microstructured optical fiber (ECF) coated by a ultraviolet curing polymer adhesive. Then, a small piece of multimode fiber (MMF) with large core diameter is spliced in front of ECF to expand the input light beam, and the parallel polymer/air double-cavity FP in such single-mode fiber (SMF)-MMF-ECF-SMF structure is constructed. Additionally, by employing a mobilized demodulation module, the interference signal is analyzed by phase demodulation method. The experimental results show that the temperature sensitivity of the sensor is 30.8 ℃−1 and the resolution is up to 1.6 × 10−4 ℃ in a range of 20 ℃–50 ℃, which can achieve high resolution temperature measurement. Furthermore, to alleviate the wavelength uncertainty of the demodulation device, a double-cavity self-reference differential phase modulation method is explored in the proposed parallel double-cavity FP. It shows that the stability could be improved to five times when system temperature is unstable, which offers an alternative method to further improve the temperature sensing resolution.
An erbium-doped fiber ring laser based on a single-mode fiber–no-core fiber–single-mode fiber (SMF-NCF-SMF) structure was constructed and experimentally demonstrated for label-free DNA hybridization measurement. The SMF-NCF-SMF structure acts as a sensing element and a filter to select the laser wavelength. The proposed fiber ring laser sensor exhibits a high optical signal-to-noise ratio (SNR, >50 dB) and narrow full width at half maximum (FWHM, <0.05 nm). Its refractive index sensitivity is 116.8 nm per RIU in the range of 1.3406–1.3705, and its detection limit is 1.79 × 10−4 RIU. By continuously monitoring the laser wavelength, we successfully achieved label-free measurement of complementary DNA (cDNA) at concentrations as low as 1 μM. Subsequently, the specificity of the sensor was detected by non-complementary DNA (N-cDNA). Experimental results show that the fiber ring laser biosensor has the advantages of simple operation, label-free measurement, and high specificity. Furthermore, it shows a broad application prospect in several fields, especially in key areas such as medical diagnosis and cancer screening.