Eun-Hee Lee

Dr. Eun-Hee Lee

Medical Device development center, Daegu-Gyeongbuk Medical Innovation Foundation, Daegu, Republic of Korea

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2022 in Fluids and Barriers of the CNS
Verified
Journal Article
Open access
PDF file
HCHyo Jin Choi
Hyo Jin Choi
MHMun Han
Mun Han
HSHyeon Seo
Hyeon Seo
CPChan Yuk Park
Chan Yuk Park
ELEun-Hee Lee
Eun-Hee Lee
APAnd Juyoung Park
And Juyoung Park
Background: Despite the great potential of FUS-BBB disruption (FUS-BBBD), it is still controversial whether FUS-BBBD acts as an inducing factor of neuro-inflammation or not, and the biological responses after FUS-BBBD triggers the inflammatory process are poorly understood. The aim of this study is to investigate the safety window for FUS levels based on a comprehensive safety assessment. Methods: The mice were treated with two different ultrasound parameters (0.25 MPa and 0.42 MPa) in the thalamus region of brain. The efficacy of BBB opening was verified by dynamic contrast-enhanced MRI (DCE-MRI) and the cavitation monitoring. The transcriptome analysis was performed to investigate the molecular response for the two BBBD conditions after FUS-mediated BBB opening in time-dependent manners. Histological analysis was used for evaluation of the tissue damage, neuronal degeneration, and activation of glial cells induced by FUS-BBBD. Results: The BBBD, as quantified by the Ktrans, was approximately threefold higher in 0.42 MPa-treated group than 0.25 MPa-treated group. While the minimal tissue/cellular damage was found in 0.25 MPa-treated group, visible damages containing microhemorrhages and degenerating neurons were detected in 0.42 MPa-treated group in accordance with the extent of BBBD. In transcriptome analysis, 0.42 MPa-treated group exhibited highly dynamic changes in the expression levels of an inflammatory response or NF-κB pathway-relative genes in a time-dependent manner whereas, 0.25 MPa was not altered. Interestingly, although it is clear that 0.42 MPa induces neuroinflammation through glial activation, neuroprotective properties were evident by the expression of A2-type astrocytes. Conclusions: Our findings propose that a well-defined BBBD parameter of 0.25 MPa could ensure the safety without cellular/tissue damage or sterile inflammatory response in the brain. Furthermore, the fact that the excessive sonication parameters at 0.42 MPa could induce a sterile inflammation response via glial activation suggested the possibility that could lead to tissue repair toward the homeostasis of the brain microenvironment through A2-type reactive astrocytes.

22 May 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JJJaeyeong Jeong
Jaeyeong Jeong
MHMun Han
Mun Han
SJSoyeon Jeon
Soyeon Jeon
YKYejin Kim
Yejin Kim
HCHyo Jin Choi
Hyo Jin Choi
ELEun-Hee Lee
Eun-Hee Lee
Focused ultrasound (FUS) with magnetic resonance imaging (MRI) guidance (MRgFUS) has emerged as a promising technique for enhancing drug delivery to the brain. Through the controlled oscillation of gas-encased microbubbles, FUS temporarily modulates the integrity of tight junctions, inducing localized blood-brain barrier disruption (BBBD) and allowing targeted drug passage. Aducanumab (ADU) has demonstrated efficacy in reducing amyloid pathology, yet its clinical application remains limited by the restrictive nature of the blood-brain barrier (BBB). This in vivo study aimed to evaluate the efficiency of ADU delivery facilitated by FUS-induced BBBD in the normal Institute of Cancer Research (ICR) mouse brain under two pressure conditions: 0.25 and 0.42 MPa. Following FUS sonication with MRI guidance, ADU concentrations in brain tissues and serum were measured via enzyme-linked immunosorbent assay (ELISA) at multiple time points. Histological analysis at 24 h post-FUS-BBBD was performed to assess ADU distribution, and tissue integrity was evaluated through hematoxylin and eosin (H&E) and Nissl staining to detect potential damage in the target regions. The results demonstrated that MRgFUS significantly increased ADU concentrations within the target areas without inducing substantial tissue damage. ADU delivery efficiency was directly correlated with the degree of BBBD, exhibiting a 7-fold increase at 0.25 MPa and a 60-fold increase at 0.42 MPa compared to sham controls, with distinct kinetic profiles observed for each condition. These findings highlight the potential of FUS-BBBD as a therapeutic strategy to enhance ADU delivery to the brain, reduce required infusion doses, and mitigate side effects associated with high-dose administration.

8 December 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
HCHyo Jin Choi
Hyo Jin Choi
MHMun Han
Mun Han
BJByeongjin Jung
Byeongjin Jung
YHYu-Ri Hong
Yu-Ri Hong
SSSeulgi Shin
Seulgi Shin
APAnd Juyoung Park
And Juyoung Park
Alzheimer’s disease (AD) is the most prevalent neurodegenerative disease worldwide, causing progressive cognitive decline, memory impairment, and neurological deficits. Methylene blue (MB), an antioxidant, has emerged as a potential drug for the treatment of AD owing to its cognitive improvement and neuroprotective functions. Despite the small molecular size of MB, which can cross the BBB, the therapeutic effective dosage using a BBB-permeable delivery system in a specific brain localization remains unclear. In this study, we presented magnetic resonance–guided focused ultrasound (MRgFUS) as a delivery system to enhance BBB permeability for the effective treatment of AD. MRgFUS using two ultrasound intensities (0.25 and 0.32 MPa) was used to intravenously deliver MB to the hippocampal region. Compared with treatment with 0.25 MPa FUS, treatment with 0.32 MPa FUS significantly enhanced MB brain accumulation. Deposition of amyloid-β (Aβ) plaques and neural cell damage was significantly reduced in 0.32 MPa FUS/MB-treated APP/PS1 mice. Furthermore, aquaporin-4 expression increased significantly in the 0.32 MPa FUS and 0.32 MPa FUS/MB groups without glial fibrillary acidic protein activation. The results from this study demonstrate that FUS improved MB delivery to the brain, and FUS/MB combination treatment reduced the number of Aβ plaques. This study revealed the potential of FUS-BBBD as an effective strategy to enhance the efficacy of therapeutic drugs for AD.

29 April 2024 in Neuromodulation: Technology at the Neural Interface
Verified
Journal Article
Open access
HSHyeon Seo
Hyeon Seo
MHMun Han
Mun Han
JCJong-Ryul Choi
Jong-Ryul Choi
SKSeungmin Kim
Seungmin Kim
JPJuyoung Park
Juyoung Park
ELEun-Hee Lee
Eun-Hee Lee
The influence of the intracranial pressure field must be discussed with the development of a single-element transducer for low-intensity transcranial focused ultrasound because the skull plays a significant role in blocking and dispersing ultrasound wave propagation. Ultrasound propagation is mainly affected by the structure and acoustic properties of the skull; thus, we aimed to investigate the impact of simplifying the acoustic properties of the skull on the simulation of the transcranial pressure field to present guidance for efficient skull modeling in full-wave simulations. We constructed a three-dimensional computational model for ultrasound transmission with the same structure but varying acoustic properties of the skull. The structural information and heterogeneous acoustic properties of the skull were acquired from computed tomography images, and we segmented the skull into three layers (3 L), including spongy and compact bones. We then assigned homogeneous acoustic properties to a single layer (1 L) or 3 L of the skull. In addition, we investigated the influence of different types of transducers and different ultrasound frequencies (1.1 MHz, 0.5 MHz, and 0.25 MHz) on the intracranial pressure field to provide a comparison of the heterogenous and homogeneous models. We indicated the importance of numerical simulations in estimating the intracranial pressure field of the skull owing to beam distortions. When we simplified the skull model, both the 1 L and 3 L models showed contours of the acoustic focus comparable to those of the heterogeneous model. When we evaluated the peak pressure and volume of the acoustic focus, the 1 L model produced a better estimation of peak pressure with a difference <10%, and the 3 L model is suitable to obtain smaller errors in the volume of the acoustic focus. In conclusion, we examined the possibility of simplification of skull models using 1 L and 3 L homogeneous properties in the numerical simulation for focused ultrasound. The results show that the layered homogeneous model can provide characteristics comparable to those of the acoustic focus in heterogeneous models.

4 February 2022 in Brain Sciences
Verified
Journal Article
Open access
PDF file
HSHyeon Seo
Hyeon Seo
HHHyungkyu Huh
Hyungkyu Huh
ELEun-Hee Lee
Eun-Hee Lee
JPJuyoung Park
Juyoung Park
Focused ultrasound is a promising therapeutic technique, as it involves the focusing of an ultrasonic beam with sufficient acoustic energy into a target brain region with high precision. Low-intensity ultrasound transmission by a single-element transducer is mostly established for neuromodulation applications and blood–brain barrier disruption for drug delivery. However, transducer positioning errors can occur without fine control over the sonication, which can affect repeatability and lead to reliability problems. The objective of this study was to determine whether the target brain region would be stable under small displacement (0.5 mm) of the transducer based on numerical simulations. Computed-tomography-derived three-dimensional models of a rat head were constructed to investigate the effects of transducer displacement in the caudate putamen (CP) and thalamus (TH). Using three different frequencies (1.1, 0.69, and 0.25 MHz), the transducer was displaced by 0.5 mm in each of the following six directions: superior, interior, anterior, posterior, left, and right. The maximum value of the intracranial pressure field was calculated, and the targeting errors were determined by the full-width-at-half-maximum (FWHM) overlap between the free water space (FWHMwater) and transcranial transmission (FWHMbase). When the transducer was positioned directly above the target region, a clear distinction between the target regions was observed, resulting in 88.3%, 81.5%, and 84.5% FWHMwater for the CP and 65.6%, 76.3%, and 64.4% FWHMwater for the TH at 1.1, 0.69, and 0.25 MHz, respectively. Small transducer displacements induced both enhancement and reduction of the peak pressure and targeting errors, compared with when the transducer was displaced in water. Small transducer displacement to the left resulted in the lowest stability, with 34.8% and 55.0% targeting accuracy (FWHMwater) at 1.1 and 0.69 MHz in the TH, respectively. In addition, the maximum pressure was reduced by up to 11% by the transducer displacement. This work provides the targeting errors induced by transducer displacements through a preclinical study and recommends that attention be paid to determining the initial sonication foci in the transverse plane in the cases of small animals.