(1) Background: The evaluation of muscles with spasticity using ultrasound elastography has attracted attention recently, and the shear wave velocity (SWV) technique can measure the mechanical properties of tissues objectively and quantitatively. The purpose of this study was to evaluate the effect of using SWV to assess the effect of Botulinum toxin type A (BoNT-A) treatment in adult patients with post-stroke lower limb spasticity. (2) Methods: We assessed the modified Ashworth Scale, the modified Tardieu Scale, and SWV at rest and after stretching before and at 1 month after BoNT-A treatment in 10 adult participants with post-stroke lower limb spasticity. (3) Results: Significant changes in SWV of the ankle joint in maximum dorsiflexion to the extent possible (SWV stretched) were observed after BoNT-A treatment. SWV stretched was positively correlated with joint range of motion. Participants whose joint range of motion did not improve (i.e., gastrocnemius medialis muscle (GCM) extension distance did not change) had significantly more reductions in SWV stretched after BoNT-A treatment. (4) Conclusions: Our results suggest that the SWV measurements may serve as a quantitative assessment to determine the effect of the BoNT-A treatment in adult stroke patients. SWV measurements to assess GCM spasticity should consider the effects of tension, material properties and activation level of muscles. The challenge is to measure SWV with matching limb positions in patients without contractures.
1 October 2016 in Journal of Stroke and Cerebrovascular Diseases
Background: We developed a novel evaluation for delirium and cognitive function named Jikei Command following Scale (JCoS). The objective of this study was to examine the reliability and validity of the JCoS. Methods: JCoS consists of 8 subitems (1, hand holding and releasing; 2, plantar dorsiflexion; 3, eye opening and closing; 4, visual pursuit; 5, mouth opening; 6, neck movement; 7, two-step command; and 8, movement sustainment). Fifty patients in the intensive care unit (ICU) participated in this study. Cronbach's alpha coefficient of JCoS total score was used for internal consistency. Intraclass correlation coefficient (ICC case 2) was used for inter-examiner reliability. The kappa coefficients for each subitem score were calculated. Concurrent validity was examined by correlation with Confusion Assessment Method for the ICU (CAM-ICU) and intensive care delirium screening checklist (ICDSC). Mini-Mental State Examination (MMSE) 2 weeks after leaving the ICU was used for predictive validity. Results: The Cronbach's alpha coefficient of the JCoS Score was 0.967. The ICC (2,1) of the JCoS Score was 0.933. The kappa coefficients of each subitem were 0.668 for 1, 0.534 for 2, 0.346 for 3, 0.721 for 4, 0.474 for 5, 0.625 for 6, 0.724 for 7, and 0.709 for 8. Correlation coefficient between JCoS and the ICDSC was –0.843, and the correlation ratio between JCoS and CAM-ICU was –0.881. Correlation coefficient between JCoS and MMSE was 0.632. Conclusions: These results suggest that JCoS has sufficient reliability and validity for evaluating about delirium and cognitive function in ICU.
18 October 2021 in Plastic and Reconstructive Surgery - Global Open
Summary: The successful reduction of a nasomaxillary fracture was performed using a three-dimensional printed model. A 16-year-old boy was struck in the left orbit by a baseball; subsequently, he was diagnosed with the nasal bone fracture at a hospital, and was referred to the authors’ department. A left nasomaxillary fracture and nasal bone fracture were diagnosed by computed tomography. Standard triangulated language data for the mirror image of the frontal process of the right maxilla were obtained from digital imaging and communications in medicine data for preparing a three-dimensional printed acrylonitrile butadiene styrene model. On postinjury day 13, the frontal process fracture was reduced via transconjunctival and intraoral approaches. After the reduction of the fracture, an absorbable plate fitting to the shape of three-dimensional printed acrylonitrile butadiene styrene model was molded, and the maxillary frontal process and infraorbital rim were reduced and fixed with an absorbable plate and screws. Postoperative computed tomography demonstrated a favorable reduction. The intraoperative use of the 3D printed acrylonitrile butadiene styrene model was helpful in the nasomaxillary fracture reduction and fixation.