The technology surrounding spinal fusion surgery has continuously evolved in tandem with advancements made in bioengineering. Over the past several decades, developments in biomechanics, surgical techniques, and materials science have expanded innovation in the spinal implant industry. This narrative review explores the current state of implant surface technologies utilized in spinal fusion surgery. This review covers various types of implant surface materials, focusing on interbody spacers composed of modified titanium, polyetheretherketone, hydroxyapatite, and other materials, as well as pedicle screw surface modifications. Advantages and disadvantages of the different surface materials are discussed, including their biocompatibility, mechanical properties, and radiographic visibility. In addition, this review examines the role of surface modifications in enhancing osseointegration and reducing implant-related complications and, hopefully, improving patient outcomes. The findings suggest that while each material has its potential advantages, further research is needed to determine the optimal surface properties for enhancing spinal fusion outcomes.
Study Design: Retrospective cohort study. Objectives: In patients undergoing adult spinal deformity (ASD) surgery we sought to: 1) report preoperative and postoperative lumbosacral fractional (LSF) curve and maximum coronal Cobb angles and 2) determine their impact on radiographic, clinical, and patient-reported outcomes (PROs). Methods: A single-institution cohort study was undertaken. The LSF curve was the cobb angle between the sacrum and most tilted lower lumbar vertebra. Coronal/sagittal vertical axis (CVA/SVA) were collected. Patients were compared between 4 groups: 1) Neutral Alignment (NA); 2) coronal malalignment only (CM); 3) Sagittal malalignment only (SM); and 4) Combined-Coronal-Sagittal-Malalignment (CCSM). Outcomes including postoperative CM, postoperative coronal vertical axis, complications, readmissions, reoperation, and PROs. Results: A total of 243 patients underwent ASD surgery with mean total instrumented levels of 13.5. Mean LSF curve was 12.1±9.9°(0.2-62.3) and mean max Cobb angle was 43.0±26.5° (0.0-134.3). The largest mean LSF curves were seen in patients with CM (14.6°) and CCSM (13.1°) compared to NA (12.1°) and SM (9.5°) (p=0.100). A higher LSF curve was seen in patients with fusion to the sacrum and instrumentation to the pelvis (p=0.009), and a higher LSF curve was associated with more TLIFs (p=0.031). Postoperatively, more TLIFs were associated with greater amount of LSF curve correction (p20° and LSF curve >5°. The LSF curve underwent greater correction in Qiu Type C patients (9.2°) compared to Type A (5.7°) and Type B (5.1°) (p=0.023); however, the max Cobb angle was similarly corrected among Qiu Types: Type A 21.8°, Type B 24.6°, and Type C 25.4° (p=0.602). Minimal differences were seen comparing the preop/postop/change in LSF curve and max Cobb angle regarding postop CM, postop CVA, complications, readmissions, reoperation, and PROs. Conclusions: The LSF curve was highest in patients with CM, CCSM, and Qiu Type C curves. Most patients had a LSF curve opposite the max Cobb angle. The max Cobb angle was more often corrected than the LSF curve. The LSF curve underwent greater correction among Qiu Type C patients, whereas the max Cobb angle was similarly corrected among all Qiu Types. No clear trend was seen regarding postoperative complications and PROs between the LSF curve and max Cobb angle.